JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gonzalez-Lavin, L.
Right arrow Articles by Graf, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gonzalez-Lavin, L.
Right arrow Articles by Graf, D.

The Journal of Thoracic and Cardiovascular Surgery, Vol 101, 75-80, Copyright © 1991 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

The pericardial valve in the aortic position ten years later

L Gonzalez-Lavin, J Gonzalez-Lavin, S Chi, B Lewis, S Amini and D Graf
Department of Surgery, Robert Wood Johnson University Hospital, New Brunswick, N.J.

To assess the behavior of the pericardial valve at 10 years after implantation, the cases of 240 patients who had undergone aortic valve replacement with the standard Ionescu-Shiley (Shiley, Inc., Irvine, Calif.) bovine pericardial valve between February 1977 and December 1983 were reassessed. Follow-up of the 224 hospital survivors was 99.6% complete. Fifty-seven valve-related events occurred. Fourteen were thrombotic events (1.2%/patient-year), 28 were intrinsic tissue failures (2.4%/patient-year), 13 were cases of prosthetic valve endocarditis (1.1%/patient-year), and 2 were paravalvular leaks (0.17%/patient-year). The linearized rate for death, reoperation, or both resulting from valve-related events was 3.6%/patient-year. Time- related hazard function for the instantaneous risk of death and/or reoperation resulting from valve-related events demonstrated an exponential increase after 80 months. These data, in conjunction with our previous reports on the histologic changes in pericardial collagen and the incidence of calcification (26/28), should be considered regarding new and future generations of pericardial bioprostheses. Although this device provides good hemodynamics and carries a low incidence of thromboembolism, it has a limited durability. New generations of pericardial valves may have improved structural features, but the behavior of glutaraldehyde-fixed, formaldehyde-stored bovine pericardium as currently selected and prepared is unlikely to change.


This article has been cited by other articles:


Home page
Eur Heart J SupplHome page
C. Huth, A. Friedl, A. Rost, and for the GELIA Study Investigator Group
Intensity of oral anticoagulation after implantation of St. Jude Medical aortic prosthesis: analysis of the GELIA Database (GELIA 4)
Eur. Heart J. Suppl., December 1, 2001; 3(suppl_Q): Q33 - Q38.
[Abstract] [PDF]


Home page
Eur Heart JHome page
A. Stahle
Homograft--the optimal aortic valve substitute?
Eur. Heart J., October 2, 2000; 21(20): 1644 - 1647.
[PDF]


Home page
CirculationHome page
T. Le Tourneau, C. Savoye, E. P. McFadden, D. Grandmougin, H.-F. Carton, J.-L. Hennequin, A. Dubar, G. Fayad, and H. Warembourg
Mid-Term Comparative Follow-Up After Aortic Valve Replacement with Carpentier-Edwards and Pericarbon Pericardial Prostheses
Circulation, November 9, 1999; 100 (2009): II-11 - II-16.
[Abstract] [Full Text] [PDF]


Home page
ANGIOLOGYHome page
J. W. Borowiec, T. W. Dubiel, H.-E. Hansson, J. Landelius, S.-O. Nystrom, and J. W. Borowiec
Pericarbon Pericardial Valve Prosthesis: Midterm Results of the Aortic Valve Replacement
Angiology, January 1, 1998; 49(1): 1 - 11.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. A. Moggio, R. W. Pooley, M. R. Sarabu, J. Christiana, A. W. Ho, and G. E. Reed
Experience with the Mitroflow aortic bioprosthesis
J. Thorac. Cardiovasc. Surg., August 1, 1994; 108(2): 215 - 220.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1991 by The American Association for Thoracic Surgery.