JTCS Speed Up Your Browser
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Akalin, H.
Right arrow Articles by Erol, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Akalin, H.
Right arrow Articles by Erol, C.

The Journal of Thoracic and Cardiovascular Surgery, Vol 103, 259-266, Copyright © 1992 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Clinical evaluation of the Omniscience cardiac valve prosthesis. Follow- up of up to 6 years

H Akalin, ET Corapcioglu, U Ozyurda, K Ucanok, A Uysalel, B Kaya, NT Eren and C Erol
Department of Cardiovascular Surgery, Ankara University, Ibn-i Sina Hospital, Turkey.

From January 1984 to June 1989, 259 Omniscience valve prostheses were implanted in 225 patients. Of the 225 patients; 143 (63.6%) received mitral, 48 (21.3%) aortic, and 34 (15.1%) double valve replacements. The early mortality rate was 8.9%; 97.6% of the patients were included in this study. These patients represent a cumulative follow-up of 407.9 patient-years, with a mean follow-up of 2.03 +/- 0.1 (standard error) years. The late mortality rate was 4.03% overall, which corresponds to 2.0% +/- 0.7%/pt-yr (SE). The annual rate of valve endocarditis was 1.0% +/- 0.5%/pt-yr (SE). The linearized rate of thromboembolism was 1.2% +/- 0.5%/pt-yr (SE). Anticoagulant-related hemorrhage occurred in 15 patients with an annual rate of 3.7% +/- 0.9%/pt-yr (SE). The linearized rate of valve thrombosis was 0.2% +/- 0.2%/pt-yr (SE). By echocardiography the mean mitral valve opening was 75.9 +/- 3.1 degrees (standard deviation) for 27 patients. During follow-up study, 136 (70.8%) patients were in New York Heart Association class I, 44 (22.9%) were in class II, and 12 (6.3%) were in class III; there were 25 (11.1%) patients in class II, 166 (73.8%) in class III, and 34 (15.1%) in class IV preoperatively. Actuarial freedom from thromboembolism was 94.5% +/- 3.6% (SE); freedom from endocarditis, 97.8% +/- 1.0% (SE); freedom from anticoagulant-related hemorrhage, 91.5% +/- 2.0% (SE); freedom from valve thrombosis 99.1% +/- 0.8% (SE); and freedom from hemolysis 98.5% +/- 1.2% (SE). Actuarial survival at 6 years is 94.0% + 2.3% (SE) overall. In conclusion, the overall rate of valve-related complications with this valve is low.


This article has been cited by other articles:


Home page
Card Surg AdultHome page
T. Gudbjartsson, T. Absi, and S. Aranki
Mitral Valve Replacement
Card. Surg. Adult, January 1, 2008; 3(2008): 1031 - 1068.
[Full Text]


Home page
ICVTSHome page
U. Ozyurda, A. R. Akar, O. Uymaz, M. Oguz, M. Ozkan, C. Yildirim, A. Aslan, and R. Tasoz
Early clinical experience with the On-X prosthetic heart valve
Interactive CardioVascular and Thoracic Surgery, December 1, 2005; 4(6): 588 - 594.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
T. Gudbjartsson, S. Aranki, and L. H. Cohn
Mechanical/Bioprosthetic Mitral Valve Replacement
Card. Surg. Adult, January 1, 2003; 2(2003): 951 - 986.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
M. S. Edwards, G. B. Russell, A. F. Edwards, J. W. Hammon Jr, A. R. Cordell, and N. D. Kon
Results of valve replacement with omniscience mechanical prostheses
Ann. Thorac. Surg., September 1, 2002; 74(3): 665 - 670.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
S. K. Choudhary, A. Mathur, P. Venugopal, B. Airan, R. Sharma, A. Bhan, A. Saxena, A. Sampath Kumar, S. K. Choudhary, A. Mathur, et al.
Prosthesis Size in Aortic Valve Replacement: Surgeon-Related Variable
Asian Cardiovasc Thorac Ann, December 1, 2000; 8(4): 333 - 338.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. J.R. Dalrymple-Hay, R. Pearce, S. Dawkins, M. P. Haw, R. K. Lamb, S. A. Livesey, and J. L. Monro
A single-center experience with 1,378 CarboMedics mechanical valve implants
Ann. Thorac. Surg., February 1, 2000; 69(2): 457 - 463.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. W. Akins
Results With Mechanical Cardiac Valvular Prostheses
Ann. Thorac. Surg., December 1, 1995; 60(6): 1836 - 1844.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
A. E. Fiane, K. Saatvedt, J. L. Svennevig, O. Geiran, K. Nordstrand, and T. Froysaker
The CarboMedics Valve: Midterm Follow-up With Analysis of Risk Factors
Ann. Thorac. Surg., October 1, 1995; 60(4): 1053 - 1058.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
C. W. Akins
Clinical evaluation of the Omniscience cardiac valve prosthesis (J THORAC CARDIOVASC SURG 1992;103:259-66)
J. Thorac. Cardiovasc. Surg., February 1, 1994; 107(2): 631 - 631.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1992 by The American Association for Thoracic Surgery.