JTCS Click here to go to SJM website.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Laub, G. W.
Right arrow Articles by McGrath, L. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Laub, G. W.
Right arrow Articles by McGrath, L. B.

The Journal of Thoracic and Cardiovascular Surgery, Vol 103, 638-641, Copyright © 1992 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

The experimental relationship between leaflet clearance and orientation of the St. Jude Medical valve in the mitral position

GW Laub, S Muralidharan, SB Pollock, MS Adkins and LB McGrath
Department of Surgery, Deborah Heart and Lung Center, Browns Mills, N.J.

The optimal orientation of the St. Jude Medical mechanical prosthesis in the mitral position has not yet been determined. While in the majority of cases the valve can perform satisfactorily regardless of valve orientation, certain circumstances can increase the risk of leaflet impingement. These valves are commonly implanted with their leaflets oriented parallel to the anatomic axis of the native leaflets (anatomic orientation) or with their prosthetic leaflets perpendicular to the axis of the native leaflets (antianatomic orientation). To determine the influence of valve orientation on the clearance from the prosthetic leaflet to the posterior ventricular wall, we calculated the clearances on all available models of the St. Jude Medical mitral valve. Clearances were computed from measurements of valve dimensions with use of an electronic caliper. In all cases the clearance in antianatomic orientation was at least 49.5% greater (mean 59%, range 49.5% to 77.5%) than in anatomic orientation.


This article has been cited by other articles:


Home page
CirculationHome page
P. Pibarot and J. G. Dumesnil
Prosthetic Heart Valves: Selection of the Optimal Prosthesis and Long-Term Management
Circulation, February 24, 2009; 119(7): 1034 - 1048.
[Full Text] [PDF]


Home page
Card Surg AdultHome page
T. Gudbjartsson, T. Absi, and S. Aranki
Mitral Valve Replacement
Card. Surg. Adult, January 1, 2008; 3(2008): 1031 - 1068.
[Full Text]


Home page
Card Surg AdultHome page
T. Gudbjartsson, S. Aranki, and L. H. Cohn
Mechanical/Bioprosthetic Mitral Valve Replacement
Card. Surg. Adult, January 1, 2003; 2(2003): 951 - 986.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1992 by The American Association for Thoracic Surgery.