JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Videm, V.
Right arrow Articles by Mollnes, T. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Videm, V.
Right arrow Articles by Mollnes, T. E.

The Journal of Thoracic and Cardiovascular Surgery, Vol 103, 806-813, Copyright © 1992 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Reduced complement activation with heparin-coated oxygenator and tubings in coronary bypass operations

V Videm, JL Svennevig, E Fosse, G Semb, A Osterud and TE Mollnes
University of Oslo Institute for Experimental Medical Research, Norway.

Complement activation after cardiopulmonary bypass is correlated with postoperative organ dysfunction. Heparin coating of the entire blood- contact surface of the cardiopulmonary bypass circuit has proved to reduce complement activation in vitro. A membrane oxygenator and tubing setup coated with functionally active heparin was compared with an uncoated, otherwise identical setup in 20 patients undergoing routine coronary bypass operations. The concentrations of C3 activation products and the terminal complement complex were measured in sensitive and specific enzyme immunoassays. Peak concentrations of C3 activation products were 90.1 (74.7 to 107.4) AU/ml (medians and 95% confidence intervals) and 52.4 (35.7 to 76.4) AU/ml with the uncoated and coated setups, respectively (p = 0.02). The corresponding concentrations of the terminal complement complex were 26.2 (20.1 to 37.5) AU/ml and 13.7 (11.1 to 25.1) AU/ml (p = 0.03). Blood loss from the mediastinal drains during the first 12 postoperative hours was 533 (416 to 975) ml in patients treated with the uncoated setup and 388 (313 to 579) ml in the coated treatment group (p = 0.06) and was significantly correlated with peak concentrations of the terminal complement complex (p = 0.01). There were no differences in neutrophil counts nor platelet numbers between the treatment groups. The approximate 45% reduction in complement activation with the heparin-coated cardiopulmonary bypass device indicates a substantial improvement of biocompatibility.


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
G. S. Murphy, E. A. Hessel II, and R. C. Groom
Optimal Perfusion During Cardiopulmonary Bypass: An Evidence-Based Approach
Anesth. Analg., May 1, 2009; 108(5): 1394 - 1417.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
E. C. McGee Jr., P. M. McCarthy, and N. Moazami
Temporary Mechanical Circulatory Support
Card. Surg. Adult, January 1, 2008; 3(2008): 507 - 534.
[Full Text]


Home page
PerfusionHome page
T. N. Hoel, V. Videm, T. E. Mollnes, K. Saatvedt, F. Brosstad, A. E. Fiane, E. Fosse, and J. L. Svennevig
Off-pump cardiac surgery abolishes complement activation
Perfusion, July 1, 2007; 22(4): 251 - 256.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
The Society of Thoracic Surgeons Blood Conservatio, V. A. Ferraris, S. P. Ferraris, S. P. Saha, E. A. Hessel II, C. K. Haan, B. D. Royston, C. R. Bridges, R. S.D. Higgins, G. Despotis, et al.
Perioperative Blood Transfusion and Blood Conservation in Cardiac Surgery: The Society of Thoracic Surgeons and The Society of Cardiovascular Anesthesiologists Clinical Practice Guideline
Ann. Thorac. Surg., May 1, 2007; 83(5_Supplement): S27 - S86.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
E. Khoshbin, A. E. Dux, H. Killer, A. W Sosnowski, R. K Firmin, and G. J Peek
A comparison of radiographic signs of pulmonary inflammation during ECMO between silicon and poly-methyl pentene oxygenators
Perfusion, January 1, 2007; 22(1): 15 - 21.
[Abstract] [PDF]


Home page
PerfusionHome page
S. F Marasco, A. Preovolos, K. Lim, and R. F Salamonsen
Thoracotomy in adults while on ECMO is associated with uncontrollable bleeding
Perfusion, January 1, 2007; 22(1): 23 - 26.
[Abstract] [PDF]


Home page
Anesth. Analg.Home page
R. Taneja and D. C. Cheng
Con: Heparin-Bonded Cardiopulmonary Bypass Circuits Should Be Routine for All Cardiac Surgical Procedures
Anesth. Analg., December 1, 2006; 103(6): 1370 - 1372.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. M. Kirshbom, B. E. Miller, K. Spitzer, K. A. Easley, C. E. Spainhour, B. E. Kogon, and K. R. Kanter
Failure of surface-modified bypass circuits to improve platelet function during pediatric cardiac surgery.
J. Thorac. Cardiovasc. Surg., September 1, 2006; 132(3): 675 - 680.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
K. G. Shann, D. S. Likosky, J. M. Murkin, R. A. Baker, Y. R. Baribeau, G. R. DeFoe, T. A. Dickinson, T. J. Gardner, H. P. Grocott, G. T. O'Connor, et al.
An evidence-based review of the practice of cardiopulmonary bypass in adults: A focus on neurologic injury, glycemic control, hemodilution, and the inflammatory response.
J. Thorac. Cardiovasc. Surg., August 1, 2006; 132(2): 283 - 290.e3.
[Full Text] [PDF]


Home page
PerfusionHome page
E. Khoshbin, C. Westrope, S. Pooboni, D. Machin, H. Killer, G. J Peek, A. W Sosnowski, and R. K Firmin
Performance of polymethyl pentene oxygenators for neonatal extracorporeal membrane oxygenation: a comparison with silicone membrane oxygenators
Perfusion, May 1, 2005; 20(3): 129 - 134.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
K. T. Lappegard, J. Riesenfeld, O.-L. Brekke, G. Bergseth, J. D. Lambris, and T. E. Mollnes
Differential Effect of Heparin Coating and Complement Inhibition on Artificial Surface-Induced Eicosanoid Production
Ann. Thorac. Surg., March 1, 2005; 79(3): 917 - 923.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J. van den Goor, R. Nieuwland, A. van den Brink, W. van Oeveren, P. Rutten, J. Tijssen, and L. Eijsman
Reduced complement activation during cardiopulmonary bypass does not affect the postoperative acute phase response
Eur. J. Cardiothorac. Surg., November 1, 2004; 26(5): 926 - 931.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
T. N Hoel, V. Videm, S. T Baksaas, T. E Mollnes, F. Brosstad, and J. L Svennevig
Comparison of a Duraflo II-coated cardiopulmonary bypass circuit and a trillium-coated oxygenator during open-heart surgery
Perfusion, May 1, 2004; 19(3): 177 - 184.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Ikuta, H. Fujii, T. Shibata, K. Hattori, H. Hirai, H. Kumano, and S. Suehiro
A new poly-2-methoxyethylacrylate-coated cardiopulmonary bypass circuit possesses superior platelet preservation and inflammatory suppression efficacy
Ann. Thorac. Surg., May 1, 2004; 77(5): 1678 - 1683.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Yoshimura, Y. Hiramatsu, Y. Sato, S. Homma, Y. Enomoto, T. Jikuya, and Y. Sakakibara
ONO-6818, a novel, potent neutrophil elastase inhibitor, reduces inflammatory mediators during simulated extracorporeal circulation
Ann. Thorac. Surg., October 1, 2003; 76(4): 1234 - 1239.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Ninomiya, K. Miyaji, and S. Takamoto
Influence of PMEA-coated bypass circuits on perioperative inflammatory response
Ann. Thorac. Surg., March 1, 2003; 75(3): 913 - 917.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
L. K. von Segesser
Safety and efficacy of heparin-bonded surfaces in cardiopulmonary bypass
J. Thorac. Cardiovasc. Surg., March 1, 2003; 125(90030): S90 - 91.
[Full Text] [PDF]


Home page
Card Surg AdultHome page
N. Moazami and P. M. McCarthy
Temporary Circulatory Support
Card. Surg. Adult, January 1, 2003; 2(2003): 495 - 520.
[Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. S. Aldea, L. O. Soltow, W. L. Chandler, C. M. Triggs, C. R. Vocelka, G. I. Crockett, Y. T. Shin, W. E. Curtis, and E. D. Verrier
Limitation of thrombin generation, platelet activation, and inflammation by elimination of cardiotomy suction in patients undergoing coronary artery bypass grafting treated with heparin-bonded circuits
J. Thorac. Cardiovasc. Surg., April 1, 2002; 123(4): 742 - 755.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
T. Scholz, R. Solberg, C. Okkenhaug, V. Videm, M. J Gallimore, O. Mathisen, T. E Mollnes, A. Bergan, O. Soreide, G. B Klintmalm, et al.
The significance of heparin-coated veno-venous bypass circuits in liver transplantation
Perfusion, January 1, 2002; 17(1): 45 - 50.
[Abstract] [PDF]


Home page
PerfusionHome page
B. Kjaergaard, P. Tolboll, S. Lyduch, and S. Trautner
A mobile system for the treatment of accidental hypothermia with extracorporeal circulation
Perfusion, December 1, 2001; 16(6): 453 - 459.
[Abstract] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
H. A. Hennein
Inflammation After Cardiopulmonary Bypass: Therapy for the Postpump Syndrome
Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2001; 5(3): 236 - 255.
[Abstract] [PDF]


Home page
PerfusionHome page
D. A Palanzo, D. L Zarro, N. J Manley, R. M Montesano, M. Quinn, B.-A. Elmore, P. A Gustafson, and J. M Castagna
Effect of Carmeda(R) BioActive Surface coating versus TrilliumTM Biopassive Surface coating of the oxygenator on circulating platelet count drop during cardiopulmonary bypass
Perfusion, July 1, 2001; 16(4): 279 - 283.
[Abstract] [PDF]


Home page
PerfusionHome page
T. Scholz, R. Solberg, C. Okkenhaug, V. Videm, M. J Gallimore, O. Mathisen, T. Pedersen, T. E Mollnes, A. Bergan, O. Soreide, et al.
Veno-venous bypass in liver transplantation: heparin-coated perfusion circuits reduce the activation of humoral defense systems in an in vitro model
Perfusion, July 1, 2001; 16(4): 285 - 292.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Suhara, Y. Sawa, M. Nishimura, H. Oshiyama, K. Yokoyama, N. Saito, and H. Matsuda
Efficacy of a new coating material, PMEA, for cardiopulmonary bypass circuits in a porcine model
Ann. Thorac. Surg., May 1, 2001; 71(5): 1603 - 1608.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
L. K. von Segesser
Safety and efficacy of heparin-bonded surfaces in cardiopulmonary bypass
J. Thorac. Cardiovasc. Surg., February 1, 2001; 121(2): 0200 - 201.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
E. Ovrum, G. Tangen, R. Oystese, M. A. L. Ringdal, and R. Istad
Comparison of two heparin-coated extracorporeal circuits with reduced systemic anticoagulation in routine coronary artery bypass operations
J. Thorac. Cardiovasc. Surg., February 1, 2001; 121(2): 0324 - 330.
[Abstract] [Full Text] [PDF]


Home page
J Biomater ApplHome page
N. Weber, H. P. Wendel, and G. Ziemer
Quality Assessment of Heparin Coatings by their Binding Capacities of Coagulation and Complement Enzymes
J Biomater Appl, July 1, 2000; 15(1): 8 - 22.
[Abstract] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
Y. Okazaki, Z.-L. Cao, S. Ohtsubo, M. Hamada, K. Naito, K. Rikitake, M. Natsuaki, and T. Itoh
Leukocyte-depleted reperfusion after long cardioplegic arrest attenuates ischemia-reperfusion injury of the coronary endothelium and myocardium in rabbit hearts
Eur. J. Cardiothorac. Surg., July 1, 2000; 18(1): 90 - 97.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
E. A. Grossi, K. Kallenbach, S. Chau, C. C. Derivaux, M. G. Aguinaga, B. M. Steinberg, D. Kim, S. Iyer, M. Tayyarah, M. Artman, et al.
Impact of heparin bonding on pediatric cardiopulmonary bypass: a prospective randomized study
Ann. Thorac. Surg., July 1, 2000; 70(1): 191 - 196.
[Abstract] [Full Text] [PDF]


Home page
J. Immunol.Home page
M. K. Pangburn, K. L. W. Pangburn, V. Koistinen, S. Meri, and A. K. Sharma
Molecular Mechanisms of Target Recognition in an Innate Immune System: Interactions Among Factor H, C3b, and Target in the Alternative Pathway of Human Complement ,2
J. Immunol., May 1, 2000; 164(9): 4742 - 4751.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Z.-L. Cao, Y. Okazaki, K. Naito, T. Ueno, M. Natsuaki, and T. Itoh
Ulinastatin attenuates reperfusion injury in the isolated blood-perfused rabbit heart
Ann. Thorac. Surg., April 1, 2000; 69(4): 1121 - 1126.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Ozawa, K. Yoshihara, N. Koyama, Y. Watanabe, N. Shiono, and Y. Takanashi
Clinical efficacy of heparin-bonded bypass circuits related to cytokine responses in children
Ann. Thorac. Surg., February 1, 2000; 69(2): 584 - 590.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. C. K. Fitch, S. Rollins, L. Matis, B. Alford, S. Aranki, C. D. Collard, M. Dewar, J. Elefteriades, R. Hines, G. Kopf, et al.
Pharmacology and Biological Efficacy of a Recombinant, Humanized, Single-Chain Antibody C5 Complement Inhibitor in Patients Undergoing Coronary Artery Bypass Graft Surgery With Cardiopulmonary Bypass
Circulation, December 21, 1999; 100(25): 2499 - 2506.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
H. L. Lazar, Y. Bao, J. Gaudiani, S. Rivers, and H. Marsh
Total Complement Inhibition : An Effective Strategy to Limit Ischemic Injury During Coronary Revascularization on Cardiopulmonary Bypass
Circulation, September 28, 1999; 100(13): 1438 - 1442.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
G. Wimmer-Greinecker, G. Matheis, S. Martens, G. Oremek, U. Abdel-Rahman, and A. Moritz
Synthetic protein treated versus heparin coated cardiopulmonary bypass surfaces: similar clinical results and minor biochemical differences
Eur. J. Cardiothorac. Surg., August 1, 1999; 16(2): 211 - 217.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Ranucci, A. Mazzucco, R. Pessotto, G. Grillone, V. Casati, L. Porreca, R. Maugeri, M. Meli, P. Magagna, S. Cirri, et al.
Heparin-coated circuits for high-risk patients: a multicenter, prospective, randomized trial
Ann. Thorac. Surg., April 1, 1999; 67(4): 994 - 1000.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
V. Videm, T. E. Mollnes, E. Fosse, B. Mohr, MD, K. Bergh, T.-A. Hagve, A. O. Aasen, and J. L. Svennevig
HEPARIN-COATED CARDIOPULMONARY BYPASS EQUIPMENT. I. BIOCOMPATIBILITY MARKERS AND DEVELOPMENT OF COMPLICATIONS IN A HIGH-RISK POPULATION
J. Thorac. Cardiovasc. Surg., April 1, 1999; 117(4): 794 - 802.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
V. Videm, T. E. Mollnes, K. Bergh, E. Fosse, B. Mohr, T.-A. Hagve, A. O. Aasen, and J. L. Svennevig
HEPARIN-COATED CARDIOPULMONARY BYPASS EQUIPMENT. II. MECHANISMS FOR REDUCED COMPLEMENT ACTIVATION IN VIVO
J. Thorac. Cardiovasc. Surg., April 1, 1999; 117(4): 803 - 809.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. L. Lazar, Y. Bao, S. Rivers, P. R. Treanor, and R. J. Shemin
Decreased incidence of arterial thrombosis using heparin-bonded intraaortic balloons
Ann. Thorac. Surg., February 1, 1999; 67(2): 446 - 449.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
C. Baufreton, M. Moczar, L. Intrator, P. G. Jansen, H. te Velthuis, P. Le Besnerais, J. P. Farcet, C. R. Wildevuur, and D. Y Loisance
Inflammatory response to cardiopulmonary bypass using two different types of heparin-coated extracorporeal circuits
Perfusion, December 1, 1998; 13(6): 419 - 427.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Baufreton, M. Kirsch, and D. Y. Loisance
Measures to control blood activation during assisted circulation
Ann. Thorac. Surg., November 1, 1998; 66(5): 1837 - 1844.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
L. H. Edmunds Jr
Inflammatory response to cardiopulmonary bypass
Ann. Thorac. Surg., November 1, 1998; 66(90050): S12 - 16.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. H. Schreurs, M. J. Wijers, Y. J. Gu, W. van Oeveren, R. T. van Domburg, J. H. de Boer, and A. J.J.C. Bogers
Heparin-coated bypass circuits: effects on inflammatory response in pediatric cardiac operations
Ann. Thorac. Surg., July 1, 1998; 66(1): 166 - 171.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
C B. Mahoney
Heparin-bonded circuits: clinical outcomes and costs
Perfusion, May 1, 1998; 13(3): 192 - 204.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. J. Gu, P. W. Boonstra, A. A. Rijnsburger, J. Haan, and W. van Oeveren
Cardiopulmonary Bypass Circuit Treated With Surface-Modifying Additives: A Clinical Evaluation of Blood Compatibility
Ann. Thorac. Surg., May 1, 1998; 65(5): 1342 - 1347.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. L. Lazar, T. Hamasaki, Y. Bao, S. Rivers, S. A. Bernard, and R. J. Shemin
Soluble Complement Receptor Type I Limits Damage During Revascularization of Ischemic Myocardium
Ann. Thorac. Surg., April 1, 1998; 65(4): 973 - 977.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
A. Belboul and N. Al-Khaja
Does heparin coating improve biocompatibility? A study on complement, blood cells and postoperative morbidity during cardiac surgery
Perfusion, December 1, 1997; 12(6): 385 - 391.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Ashraf, Y. Tian, D. Cowan, A. Entress, P. G. Martin, and K. G. Watterson
Release of Proinflammatory Cytokines During Pediatric Cardiopulmonary Bypass: Heparin-Bonded Versus Nonbonded Oxygenators
Ann. Thorac. Surg., December 1, 1997; 64(6): 1790 - 1794.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
H. t. Velthuis, C. Baufreton, P. G. M. Jansen, C. M. Thijs, C. E. Hack, A. Sturk, C. R. H. Wildevuur, and D. Y. Loisance
HEPARIN COATING OF EXTRACORPOREAL CIRCUITS INHIBITS CONTACT ACTIVATION DURING CARDIAC OPERATIONS
J. Thorac. Cardiovasc. Surg., July 1, 1997; 114(1): 117 - 122.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
H. L. Lazar, X. Zhang, T. Hamasaki, C. A. Memmelo, P. Treanor, S. Rivers, G. S. Aldea, S. A. Bernard, and R. J. Shemin
Heparin-Bonded Circuits Decrease Myocardial Ischemic Damage: An Experimental Study
Ann. Thorac. Surg., June 1, 1997; 63(6): 1701 - 1705.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
S. Bannan, A. Danby, D. Cowan, S. Ashraf, and P. G. Martin
Low Heparinization With Heparin-Bonded Bypass Circuits: Is It a Safe Strategy?
Ann. Thorac. Surg., March 1, 1997; 63(3): 663 - 668.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
A. H. Kuitunen, L. J. Heikkila, and M. T. Salmenpera
Cardiopulmonary Bypass With Heparin-Coated Circuits and Reduced Systemic Anticoagulation
Ann. Thorac. Surg., February 1, 1997; 63(2): 438 - 444.
[Abstract] [Full Text]


Home page
PerfusionHome page
H E Hogevold, O Moen, E Fosse, P Venge, J Braten, C Andersson, and T Lyberg
Effects of heparin coating on the expression of CD11b, CD11c and CD62L by leucocytes in extracorporeal circulation in vitro
Perfusion, January 1, 1997; 12(1): 9 - 20.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Ashraf, Y. Tian, D. Cowan, U. Nair, R. Chatrath, N. R. Saunders, K. G. Watterson, and P. G. Martin
""Low-Dose"" Aprotinin Modifies Hemostasis but Not Proinflammatory Cytokine Release
Ann. Thorac. Surg., January 1, 1997; 63(1): 68 - 73.
[Abstract] [Full Text]


Home page
PerfusionHome page
C. Baufreton, P. Le Besnerais, P. Jansen, J. P. Mazzucotelli, C. R. Wildevuur, and D. Y Loisance
Clinical outcome after coronary surgery with heparin-coated extracorporeal circuits for cardiopulmonary bypass
Perfusion, November 1, 1996; 11(6): 437 - 443.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
E. Ovrum, E. A. Holen, G. Tangen, and M.-A. L. Ringdal
Heparinized Cardiopulmonary Bypass and Full Heparin Dose Marginally Improve Clinical Performance
Ann. Thorac. Surg., October 1, 1996; 62(4): 1128 - 1133.
[Abstract] [Full Text]


Home page
PerfusionHome page
M. Yii, T. Gourlay, J. Fleming, B. Matata, and K. Taylor
Evaluation of Carmeda(R) Bioactive Surface (CBAS(R)), Duraflo II and a novel nonspecific protease-modified surface using a new in vitro model simulating cardiopulmonary bypass
Perfusion, May 1, 1996; 11(3): 229 - 240.
[PDF]


Home page
PerfusionHome page
L. K von Segesser
Surface coating of cardiopulmonary bypass circuits
Perfusion, May 1, 1996; 11(3): 241 - 245.
[PDF]


Home page
Ann. Thorac. Surg.Home page
P. G. M. Jansen, C. Baufreton, P. Le Besnerais, D. Y. Loisance, and C. R. H. Wildevuur
Heparin-Coated Circuits and Aprotinin Prime for Coronary Artery Bypass Grafting
Ann. Thorac. Surg., May 1, 1996; 61(5): 1363 - 1366.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. L. Korn, C. A. Fisher, E. R. Livingston, N. Stenach, S. J. Fishman, V. Jeevanandam, and V. P. Addonizio
THE EFFECTS OF CARMEDA BIOACTIVE SURFACE ON HUMAN BLOOD COMPONENTS DURING SIMULATED EXTRACORPOREAL CIRCULATION
J. Thorac. Cardiovasc. Surg., May 1, 1996; 111(5): 1073 - 1084.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
H. t. Velthuis, P. G. M. Jansen, C. E. Hack, L. Eijsman, and C. R. H. Wildevuur
Specific Complement Inhibition With Heparin-Coated Extracorporeal Circuits
Ann. Thorac. Surg., April 1, 1996; 61(4): 1153 - 1157.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
D. D. Muehrcke, P. M. McCarthy, R. W. Stewart, R. C. Foster, D. A. Ogella, J. A. Borsh, and D. M. Cosgrove III
Extracorporeal Membrane Oxygenation for Postcardiotomy Cardiogenic Shock
Ann. Thorac. Surg., February 1, 1996; 61(2): 684 - 691.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. C. Gorman, N. P. Ziats, A. K. Rao, N. Gikakis, L. Sun, M. M. H. Khan, N. Stenach, S. Sapatnekar, V. Chouhan, J. H. Gorman III, et al.
SURFACE-BOUND HEPARIN FAILS TO REDUCE THROMBIN FORMATION DURING CLINICAL CARDIOPULMONARY BYPASS
J. Thorac. Cardiovasc. Surg., January 1, 1996; 111(1): 1 - 12.
[Abstract] [Full Text]


Home page
PerfusionHome page
D. F Larson, M. Bowers, and H W. Schechner
Neutrophil activation during cardiopulmonary bypass in paediatric and adult patients
Perfusion, January 1, 1996; 11(1): 21 - 27.
[Abstract] [PDF]


Home page
PerfusionHome page
J. Svennevig, S. Tollofsrud, U. Kongsgaard, H. Noddeland, B. Mohr, M. Ozer, and T. Mollnes
Complement activation during and after open-heart surgery is only marginally affected by the choice of fluid for volume replacement
Perfusion, January 1, 1996; 11(4): 326 - 332.
[Abstract] [PDF]


Home page
PerfusionHome page
A. Hamulu, B. Discigil, M. Ozbaran, T. Calkavur, E. Kara, A. Kokuludag, S. Buket, and O. Bilkay
Complement consumption during cardiopulmonary bypass: comparison of Duraflo II heparin-coated and uncoated circuits in fully heparinized patients
Perfusion, January 1, 1996; 11(4): 333 - 337.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
E. Ovrum, T. E. Mollnes, E. Fosse, E. A. Holen, G. Tangen, M.-A. L. Ringdal, and V. Videm
High and Low Heparin Dose With Heparin-Coated Cardiopulmonary Bypass: Activation of Complement and Granulocytes
Ann. Thorac. Surg., December 1, 1995; 60(6): 1755 - 1761.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
E. Ovrum, T. E. Mollnes, E. Fosse, E. A. Holen, G. Tangen, M. Abdelnoor, M.-A. L. Ringdal, R. Oystese, and P. Venge
COMPLEMENT AND GRANULOCYTE ACTIVATION IN TWO DIFFERENT TYPES OF HEPARINIZED EXTRACORPOREAL CIRCUITS
J. Thorac. Cardiovasc. Surg., December 1, 1995; 110(6): 1623 - 1632.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
O. Moen, E. Fosse, V. Brockmeier, C. Andersson, T. E. Mollnes, K. Hogasen, and P. Venge
Disparity in Blood Activation by Two Different Heparin-Coated Cardiopulmonary Bypass Systems
Ann. Thorac. Surg., November 1, 1995; 60(5): 1317 - 1323.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. G. M. Jansen, H. t. Velthuis, R. A. J. M. Huybregts, R. Paulus, E. R. Bulder, H. I. van der Spoel, P. D. Bezemer, E. H. Slaats, L. Eijsman, and C. R. H. Wildevuur
Reduced complement activation and improved postoperative performance after cardiopulmonary bypass with heparin-coated circuits
J. Thorac. Cardiovasc. Surg., September 1, 1995; 110(3): 829 - 834.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. D. Muehrcke, P. M. McCarthy, R. W. Stewart, S. Seshagiri, D. A. Ogella, R. C. Foster, and D. M. Cosgrove
Complications of extracorporeal life support systems using heparin-bound surfaces: The risk of intracardiac clot formation
J. Thorac. Cardiovasc. Surg., September 1, 1995; 110(3): 843 - 851.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
E. Ovrum, E. A. Holen, G. Tangen, F. Brosstad, M. Abdelnoor, M.-A. L. Ringdal, R. Oystese, and R. Istad
Completely Heparinized Cardiopulmonary Bypass and Reduced Systemic Heparin: Clinical and Hemostatic Effects
Ann. Thorac. Surg., August 1, 1995; 60(2): 365 - 371.
[Abstract] [Full Text]


Home page
PerfusionHome page
L. von Segesser, J. Schilling, B. Leskosek, K. Marquardt, and M. Turina
Surface treatments for perfusion devices
Perfusion, May 1, 1994; 9(3): 197 - 205.
[PDF]


Home page
PerfusionHome page
Z. A Varga
Autologous plateletpheresis in cardiac surgery
Perfusion, November 1, 1993; 8(6): 471 - 476.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS