JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Curtis, J. J.
Right arrow Articles by Landreneau, R. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Curtis, J. J.
Right arrow Articles by Landreneau, R. J.

The Journal of Thoracic and Cardiovascular Surgery, Vol 104, 554-560, Copyright © 1992 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Experience with the Sarns centrifugal pump in postcardiotomy ventricular failure

JJ Curtis, JT Walls, R Schmaltz, TM Boley, W Nawarawong and RJ Landreneau
Division of Cardiothoracic Surgery, University of Missouri-Columbia 65212.

The reported clinical use of the Sarns centrifugal pump (Sarns, Inc./3M, Ann Arbor, Mich.) as a cardiac assist device for postcardiotomy ventricular failure is limited. During a 25-month period ending November 1988, we used 40 Sarns centrifugal pumps as univentricular or biventricular cardiac assist devices in 27 patients who could not be weaned from cardiopulmonary bypass despite maximal pharmacologic and intraaortic balloon support. Eighteen men and nine women with a mean age of 60.4 years (28 to 83) required assistance. Left ventricular assist alone was used in 12 patients, right ventricular assist in 2, and biventricular assist in 13. The duration of assist ranged from 2 to 434 hours (median 45). Centrifugal assist was successful in weaning 100% of the patients. Ten of 27 patients (37%) improved hemodynamically, allowing removal of the device(s), and 5 of 27 (18.5%) survived hospitalization. Survival of patients requiring left ventricular assist only was 33.3% (4/12). Complications were common and included renal failure, hemorrhage, coagulopathy, ventricular arrhythmias, sepsis, cerebrovascular accident, and wound infection. During 3560 centrifugal pump hours, no pump thrombosis was observed. The Sarns centrifugal pump is an effective assist device when used to salvage patients who otherwise cannot be weaned from cardiopulmonary bypass. Statistical analysis of preoperative patient characteristics, operative risk factors, and postoperative complications failed to predict which patients would be weaned from cardiac assist or which would survive.


This article has been cited by other articles:


Home page
PerfusionHome page
S. Tokunaga, T. Nakano, R. Tominaga, T. Imaizumi, A. Takeshita, and H. Yasui
Effects of nonpulsatile left heart bypass on renal sympathetic nerve activity in rabbits
Perfusion, December 1, 2000; 15(6): 515 - 520.
[Abstract] [PDF]


Home page
HeartHome page
J P Bourke, A Loaiza, G Parry, C Hilton, S Furniss, J Dark, and J Forty
Role of orthotopic heart transplantation in the management of patients with recurrent ventricular tachyarrhythmias following myocardial infarction
Heart, November 1, 1998; 80(5): 473 - 478.
[Abstract] [Full Text]


Home page
Eur. J. Cardiothorac. Surg.Home page
Y. Nose and K. Kawahito
Development of a non-pulsatile permanent rotary blood pump
Eur. J. Cardiothorac. Surg., April 1, 1997; 11(suppl): S32 - S38.
[Abstract] [PDF]


Home page
ANGIOLOGYHome page
Y. Moriyama, Y. Iguro, S. Shimokawa, H. Saigenji, H. Toyohira, and A. Taira
Successful Application of Hypothermia Combined with Intra-Aortic Balloon Pump Support to Low-Cardiac-Output State After Open Heart Surgery
Angiology, June 1, 1996; 47(6): 595 - 599.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. J. Curtis, J. T. Walls, R. A. Schmaltz, T. L. Demmy, C. C. Wagner-Mann, and C. A. McKenney
Use of Centrifugal Pumps for Postcardiotomy Ventricular Failure: Technique and Anticoagulation
Ann. Thorac. Surg., January 1, 1996; 61(1): 296 - 300.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1992 by The American Association for Thoracic Surgery.