JTCS KCI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Geddes, L. A.
Right arrow Articles by Janas, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Geddes, L. A.
Right arrow Articles by Janas, W.

The Journal of Thoracic and Cardiovascular Surgery, Vol 104, 1435-1442, Copyright © 1992 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Output power and metabolic input power of skeletal muscle contracting linearly to compress a pouch in a mock circulatory system

LA Geddes, SF Badylak, WA Tacker and W Janas
Hillenbrand Biomedical Engineering Center, Purdue University, West Lafayette, IN 47907-1293.

Output power and metabolic input power values were determined for unconditioned canine latissimus dorsi (two), gastrocnemius (seven), and triceps (three) muscles contracting linearly to cause compression of a doubly valved pouch in a hydraulic model of the circulation. The motor nerves to the muscles were stimulated tetanically with 450 msec trains of 0.1 msec pulses having a frequency of 50/sec. The muscles were contracted 10, 20, 30, and 40 times per minute and pouch output in milliliters per minute was measured directly for each muscle at each contraction (train) rate. The output power in milliwatts was determined by two methods: (1) by using the pouch output and the pressure rise imparted to the stroke volume (average power) and (2) by using the pressure-volume loop. Metabolic input power in milliwatts was determined from the oxygen consumption in milliliters per minute of the working muscle. It was found that as the pouch output was increased, the pouch output power and the metabolic input power both increased. The average power output was slightly less than that computed from the pressure-volume loop. The mean output power values, when pumping at L liters per minute, were 0.62 L (average) and 0.75 L mW/gm (pressure- volume loop) for the latissimus dorsi muscles; 0.83 L (average) and 1.16 L mW/gm (pressure-volume loop) for the gastrocnemius muscles; and 0.55 L (average) and 0.66 L mW/gm (pressure-volume loop) for the triceps muscles. The percent efficiency of energy conversion ranged from 9.2% to 17.8% for the latissimus dorsi muscles, from 5.1% to 19.5% for the gastrocnemius muscles, and from 10.5% to 27.3% for the triceps muscles. However, it should not be concluded that one muscle type is better than another on the basis of percent efficiency because efficiency does not take endurance into account. An important observation in this study relates to the large output obtained with the three linearly contracting muscle types. All were capable of pumping in excess of 1.5 L/min. A second observation relates to the absence of fatigue, although determination of endurance was not an objective in these studies.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
D. R. Trumble and J. A. Magovern
A muscle-powered energy delivery system and means for chronic in vivo testing
J Appl Physiol, June 1, 1999; 86(6): 2106 - 2114.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
M. Petrou, C. Bowles, and M. Yacoub
Comparative study of the biomechanical performance of trained and untrained skeletal muscle
Cardiovasc Res, March 1, 1997; 33(3): 583 - 592.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. Watanabe, T. Misaki, M. Takahashi, H. Ohtake, Y. Tsunezuka, M. Wada, and Y. Watanabe
Efficacy of a skeletal muscle-powered dynamic patch: Part 2. Right ventricular assistance
Ann. Thorac. Surg., February 1, 1995; 59(2): 313 - 319.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1992 by The American Association for Thoracic Surgery.