JTCS Tips for Better Browsing
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vinograd, I.
Right arrow Articles by Nevo, Z.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vinograd, I.
Right arrow Articles by Nevo, Z.

J Thorac Cardiovasc Surg 1994;107:1255-1261
© 1994 Mosby, Inc.


GENERAL THORACIC SURGERY

A new intratracheal stent made from nitinol, an alloy with "shape memory effect"

Itzhak Vinograd, MDa, Baruch Klin, MDa, Tamar Brosh, PhDb, Mark Weinberg, MD, PhDa, Yosef Flomenblit, PhDa, Zvi Nevo, PhDc


Zerifin and Tel Aviv, Israel

Supported by a grant from The Sander Research Fund, Tel Aviv University.

Received for publication June 28, 1993. Accepted for publication Sept. 21, 1993. Address for reprints: I. Vinograd, MD, Head, Department of Pediatric Surgery, Assaf Harofeh Medical Center, Zerifin 70300, Israel.

Abstract

Temporary or permanent tracheal splinting in pediatric patients may be indicated in tracheomalacia or bronchomalacia, repair of congenital tracheal stenosis, and after tracheal resection. This study presents the results of the development of a new intraluminal airway stent made from titanium alloy, a metal with "shape memory effect." At low temperatures (martensitic state) the titanium alloy stent can be fashioned into a specific shape; then when heated to a higher temperature (austenitic state) the stent alters its shape, only to regain its original shape when recooled to the lower temperature. The stent, connected to a small electric power supply, was introduced into 20 young rabbits with the use of a 2.5 cm rigid bronchoscope. After implantation in the martensitic state the stent was warmed to 40° C, the austenitic state, by an electric current of 1.5 to 3 ampere for 1 to 2 seconds. After a period of 8 to 10 weeks the stent was removed (in its martensitic state) through the same-sized bronchoscope after being cooled with 3 to 4 ml of 80% alcohol solution at 6° C. No signs of airway obstruction developed in any of the animals after implantation or extraction of the stent. The biomechanical properties of the trachea, as shown by strain measurements with the use of incremental forces, showed significant differences between the stented and unstented segments (p <0.005). The titanium alloy intratracheal stent adequately fulfilled the requirements of a temporary intraluminal airway splint, and because of its unique feature of shape memory effect the stent could be inserted, fixed, and removed easily, even in very small airways. (J THORACCARDIOVASCSURG1994;107:1255-61)




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
S. A. Husain, D. Finch, M. Ahmed, A. Morgan, and M. R. Hetzel
Long-Term Follow-Up of Ultraflex Metallic Stents in Benign and Malignant Central Airway Obstruction
Ann. Thorac. Surg., April 1, 2007; 83(4): 1251 - 1256.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
I. Vinograd
Reply to the Editor
J. Thorac. Cardiovasc. Surg., January 1, 2006; 131(1): 254 - 254.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Lemaire, W. R. Burfeind, E. Toloza, S. Balderson, R. P. Petersen, D. H. Harpole Jr, and T. A. D'Amico
Outcomes of Tracheobronchial Stents in Patients With Malignant Airway Disease
Ann. Thorac. Surg., August 1, 2005; 80(2): 434 - 438.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
I. Vinograd, S. Keidar, M. Weinberg, and A. Silbiger
Treatment of airway obstruction by metallic stents in infants and children
J. Thorac. Cardiovasc. Surg., July 1, 2005; 130(1): 146 - 150.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J. B. Pillai, J. Smith, A. Hasan, and D. Spencer
Review of pediatric airway malacia and its management, with emphasis on stenting
Eur. J. Cardiothorac. Surg., January 1, 2005; 27(1): 35 - 44.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. Kumar, A. P. Bush, G. P. Ladas, and P. Goldstraw
Tracheobronchial obstruction in children: experience with endoscopic airway stenting
Ann. Thorac. Surg., May 1, 2003; 75(5): 1579 - 1586.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J. P. Jacobs, J. A. Quintessenza, L. M. Botero, H. M. van Gelder, J. M. Giroud, M. J. Elliott, and C. Herberhold
The role of airway stents in the management of pediatric tracheal, carinal, and bronchial disease
Eur. J. Cardiothorac. Surg., November 1, 2000; 18(5): 505 - 512.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
T. Miyazawa, M. Yamakido, S. Ikeda, K. Furukawa, Y. Takiguchi, H. Tada, and T. Shirakusa
Implantation of Ultraflex Nitinol Stents in Malignant Tracheobronchial Stenoses
Chest, October 1, 2000; 118(4): 959 - 965.
[Abstract] [Full Text] [PDF]


Home page
Arch Otolaryngol Head Neck SurgHome page
R. H. Furman, C. L. Backer, M. E. Dunham, J. Donaldson, C. Mavroudis, and L. D. Holinger
The Use of Balloon-Expandable Metallic Stents in the Treatment of Pediatric Tracheomalacia and Bronchomalacia
Arch Otolaryngol Head Neck Surg, February 1, 1999; 125(2): 203 - 207.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1994 by The American Association for Thoracic Surgery.