JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Matsui, T.
Right arrow Articles by Ikada, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Matsui, T.
Right arrow Articles by Ikada, Y.

J Thorac Cardiovasc Surg 1994;108:162-168
© 1994 Mosby, Inc.


GENERAL THORACIC SURGERY

Bioabsorbable struts made from poly-L-lactide and their application for treatment of chest deformity

T. Matsui, MD, M. Kitano, MD, T. Nakamura, MDa, Y. Shimizu, MDa, S-H. Hyon, PhDa, Y. Ikada, MD, PhDa


Nara and Kyoto, Japan

Received for publication Aug. 5, 1993. Accepted for publication Nov. 29, 1993. Address for reprints: T. Nakamura, MD, Research Center for Biomedical Engineering, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606, Japan.

Abstract

Poly-L-lactide, a polymer of lactic acid, shows slow degradation in living tissue. Poly-L-lactide plate of high molecular weight maintains more than 90% of its initial mechanical properties for more than 3 months after implantation. Using struts made from poly-L-lactide plate, we performed chest wall reconstruction in 56 patients: for postoperative chronic sternal dehiscence in 23 and sternal elevation for pectus excavatum in 33 cases. The postoperative external appearances of the anterior chest were improved in comparison with the preoperative state in all cases. The internal features were evaluated by computed tomographic scan. Neither postoperative wound infection nor respiratory complication was observed, and no tendency for regression of the anterior chest occurred in any of the patients. In 3 of 56 cases (5.4%; one in the sternal dehiscence group and two in the pectus excavatum group), it was necessary to remove part of the strut because of overgrowth of granulation tissue around the implanted material after 4, 12, and 13 postoperative months, respectively. In the pectus excavatum group, the computed tomographic evaluations showed that poly-L-lactide strut maintained sufficient strength to support the thoracic wall 5 months after implantation. These findings suggest that the bioabsorbable poly-L-lactide strut is a promising material for surgical treatment of chest deformity. (J THORACCARDIOVASCSURG1994;108:162-8)




This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
X. Qin, H. Tang, Z. Xu, X. Zhao, Y. Sun, Z. Gong, and L. Duan
Chest wall reconstruction with two types of biodegradable polymer prostheses in dogs
Eur. J. Cardiothorac. Surg., October 1, 2008; 34(4): 870 - 874.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
M. Calik, O. K. Aribas, and F. Kanat
The effect of costal cartilage resection on the chest wall development: a morphometric evaluation
Eur. J. Cardiothorac. Surg., November 1, 2007; 32(5): 756 - 760.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
Y. Tsunezuka, T. Iseki, H. Sato, N. Ishikawa, M. Oda, and G. Watanabe
A New Technique of Fixing a Costal Coaptation Pin after Resection of Rib Segment
Asian Cardiovasc Thorac Ann, September 1, 2004; 12(3): 224 - 226.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
A. Erdogan, A. Ayten, N. Oz, and A. Demircan
Early and Long-Term Results of Surgical Repair of Pectus Excavatum
Asian Cardiovasc Thorac Ann, March 1, 2002; 10(1): 39 - 42.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
E. Onursal, A. Toker, K. Bostanci, U. Alpagut, and E. Tireli
A complication of pectus excavatum operation: endomyocardial steel strut
Ann. Thorac. Surg., September 1, 1999; 68(3): 1082 - 1083.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Tatsumi, N. Kanemitsu, T. Nakamura, and Y. Shimizu
Bioabsorbable poly-L-lactide costal coaptation pins and their clinical application in thoracotomy
Ann. Thorac. Surg., March 1, 1999; 67(3): 765 - 768.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. Kowalewski and M. Brocki
Long-term observation in 68 patients operated on for pectus excavatum: surgical repair of funnel chest
Ann. Thorac. Surg., March 1, 1999; 67(3): 821 - 824.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. M. Actis Dato, M. D. Summa, A. A. Dato, G. Zattera, and G. Fortunato
Treatment of pectus excavatum: Bioabsorbable or metal strut?
J. Thorac. Cardiovasc. Surg., July 1, 1995; 110(1): 277 - 278.
[Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
T. Nakamura
Treatment of pectus excavatum: Bioabsorbable or metal strut?
J. Thorac. Cardiovasc. Surg., July 1, 1995; 110(1): 278 - 279.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1994 by The American Association for Thoracic Surgery.