|
|
||||||||
J Thorac Cardiovasc Surg 1994;108:609-615
© 1994 Mosby, Inc.
CARDIOPULMONARY BYPASS, |
Kobe, Japan
From the Department of Surgery, Division II, School of Medicine, Kobe University, Kobe, Japan.
Presented in part at Sixty-fourth Scientific Sessions of the American Heart Association, November 1991, Anaheim, Calif.
Received for publication Oct. 1, 1993. Accepted for publication May 10, 1994. Address for reprints: Takuro Tsukube, MD, Department of Surgery, Division II, School of Medicine, Kobe University, 7-5-2 Kusunoki- cho, Chuou-ku, Kobe 650, Japan.
Abstract
The usefulness of dynamic cardiomyoplasty has been demonstrated repeatedly, both experimentally and clinically. Although clinical applications of dynamic cardiomyoplasty to ischemic heart disease have been reported, its effect on the coronary blood flow has never been discussed. Therefore, we tested the hypothesis that dynamic cardiomyoplasty might adversely affect coronary arterial blood flow through compression of the coronary arteries during systolic skeletal muscular contraction and incomplete relaxation of the skeletal muscle flap during diastole. Dynamic cardiomyoplasty was performed in seven mongrel dogs with the use of a left latissimus dorsi muscle flap, paced synchronously with the R wave of the electrocardiogram. A 3F Doppler catheter was placed in the left main trunk of the coronary artery to assess the instantaneous changes of coronary flow velocity by fast Fourier transformation analysis. We compared systolic and diastolic properties during assisted versus unassisted cardiac cycles by calculating the peak velocity and the time-velocity integral. During assisted cardiac cycles, a significant enhancement of coronary arterial blood flow velocity was demonstrated by significant increases in both systolic and diastolic peak velocity (26.9% ± 6.5%, p < 0.005; 4.0% ± 1.6%, p < 0.05, respectively) and time-velocity integral (20.9% ± 4.8%, p < 0.05; 10.0% ± 4.6%, p < 0.05, respectively). Enhancement of coronary arterial blood flow velocity was associated with an increase in mean aortic pressure (16.4% ± 1.3%, p< 0.005) and descending aortic flow (67.5% ± 5.3%, p < 0.005). Also, the improved systolic coronary arterial blood flow velocity was consistent with an increase in systolic aortic pressure (15.8% ± 1.5%, p < 0.005), and enhancement of diastolic coronary arterial blood flow velocity was associated with an increase in diastolic aortic pressure (8.6% ± 2.3%, p < 0.01). We concluded that coronary arterial blood flow velocity was increased by the enhancement of cardiac function as a result of dynamic cardiomyoplasty, leading to an increase of coronary perfusion pressure and cardiac output. (J THORAC CARDIOVASC SURG 1994;108:609-15)
This article has been cited by other articles:
![]() |
C. A. M. van Doorn, M. S. Bhabra, D. N. Hopkinson, D. Barman, J. J. Cranley, Mrcvs, and T. L. Hooper Latissimus Dorsi Muscle Blood Flow During Synchronized Contraction: Implications for Cardiomyoplasty Ann. Thorac. Surg., February 1, 1996; 61(2): 603 - 609. [Abstract] [Full Text] |
||||
![]() |
R. E. Oakley Effect of cardiomyoplasty on coronary artery flow J. Thorac. Cardiovasc. Surg., July 1, 1995; 110(1): 280 - 280. [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |