|
|
||||||||
J Thorac Cardiovasc Surg 1994;108:1076-1082
© 1994 Mosby, Inc.
CARDIOPULMONARY BYPASS, |
St. Louis, Mo.
Supported in part by a research grant from Medtronic-Hemotec, Englewood, Colo.
Received for publication Dec. 23, 1993. Accepted for publication April 27, 1994. Address for reprints: George Despotis, MD, Division of Cardiothoracic Anesthesiology, Department of Anesthesiology, Box 8054, Washington University School of Medicine, 660 South Euclid Ave., St. Louis, MO 63110.
Abstract
Previous reports suggest that activated clotting times do not correlate with heparin concentration during cardiopulmonary bypass. This study was designed to compare whole blood heparin concentration and activated clotting time measurements with laboratory-based plasma heparin concentration. Sixty-two patients having cardiac operations requiring cardiopulmonary bypass were enrolled in this study. The study was conducted in two phases. In phase I of this trial, blood specimens were obtained from 30 patients before heparin administration and after each of three heparin doses (20, 80, and 150 U/kg). In phase II, blood specimens were obtained from 32 patients before heparin administration and 10 minutes after each of the following: heparin administration (250 or 300 U/kg), initiation of cardiopulmonary bypass, achievement of hypothermia, initiation of rewarming, and immediately before discontinuation of bypass. Blood specimens were used to measure activated clotting time (kaolin and celite), whole blood heparin concentration, and anti-factor Xa plasma heparin concentration. In phase I, activated clotting time (celite: r = 0.91; kaolin: r = 0.93) and whole blood heparin concentration (r = 0.98) measurements correlated well with plasma heparin concentration. After initiation of cardiopulmonary bypass (phase II), weak correlations for activated clotting time measurements (celite: r = 0.34; kaolin: r = 0.59) and a strong correlation for whole blood heparin concentration (r = 0.95) were evident when compared with plasma heparin concentration. During bypass, activated clotting time measurements also inversely correlated with temperature (celite: r = -0.21; kaolin: r = -0.19) and hematocrit (celite: r = -0.26; kaolin: r = -0.21). A weak correlation between activated clotting time measurements and plasma heparin concentration is evident during the cardiopulmonary bypass period, probably because of the influence of both reduced hematocrit and temperature on the activated clotting time assay. In contrast, whole blood heparin measurements correlate well with plasma heparin concentration before and during bypass. Further studies are needed to determine whether maintaining heparin levels during cardiopulmonary bypass by monitoring heparin concentration is more effective in preventing consumptive activation of the hemostatic system, reducing bleeding, and minimizing the use of blood products after cardiopulmonary bypass when compared with a protocol based on activated clotting time. (J THORAC CARDIOVASC SURG 1994;108:1076-82)
This article has been cited by other articles:
![]() |
N. A. Guzzetta, T. Bajaj, T. Fazlollah, F. Szlam, E. Wilson, A. Kaiser, S. R. Tosone, and B. E. Miller A Comparison of Heparin Management Strategies in Infants Undergoing Cardiopulmonary Bypass Anesth. Analg., February 1, 2008; 106(2): 419 - 425. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. H. Levy, K. A. Tanaka, and J. M. Bailey Cardiac Surgical Pharmacology Card. Surg. Adult, January 1, 2008; 3(2008): 77 - 110. [Full Text] |
||||
![]() |
J. W. Hammon Extracorporeal Circulation: The Response of Humoral and Cellular Elements of Blood to Extracorporeal Circulation Card. Surg. Adult, January 1, 2008; 3(2008): 370 - 389. [Full Text] |
||||
![]() |
L. H. Edmunds Jr and R. W. Colman Thrombin During Cardiopulmonary Bypass Ann. Thorac. Surg., December 1, 2006; 82(6): 2315 - 2322. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Tremey, B. Szekely, S. Schlumberger, D. Francois, N. Liu, K. Sievert, and M. Fischler Anticoagulation monitoring during vascular surgery: accuracy of the Hemochron(R) low range activated clotting time (ACT-LR) Br. J. Anaesth., October 1, 2006; 97(4): 453 - 459. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. T. Ganter, A. Monn, R. Tavakoli, M. Genoni, R. Klaghofer, L. Furrer, H. Honegger, and C. K. Hofer Monitoring activated clotting time for combined heparin and aprotinin application: in vivo evaluation of a new aprotinin-insensitive test using Sonoclot. Eur. J. Cardiothorac. Surg., August 1, 2006; 30(2): 278 - 284. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Vincentelli, B. Jude, and S. Belisle Antithrombotic therapy in cardiac surgery: [Traitement antithrombotique en chirurgie cardiaque]. Can J Anesth, June 1, 2006; 53(6_suppl): S89 - S102. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y P. Bosch, Y M Ganushchak, and D S de Jong Comparison of ACT point-of-care measurements: repeatability and agreement Perfusion, January 1, 2006; 21(1): 27 - 31. [Abstract] [PDF] |
||||
![]() |
M. T. Ganter, S. Dalbert, K. Graves, R. Klaghofer, A. Zollinger, and C. K. Hofer Monitoring Activated Clotting Time for Combined Heparin and Aprotinin Application: An In Vitro Evaluation of a New Aprotinin-Insensitive Test Using SONOCLOT Anesth. Analg., August 1, 2005; 101(2): 308 - 314. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. A Spinler, A. K Wittkowsky, E. A Nutescu, and M. A Smythe Anticoagulation Monitoring Part 2: Unfractionated Heparin and Low-Molecular-Weight Heparin Ann. Pharmacother., July 1, 2005; 39(7): 1275 - 1285. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Smythe and A. Caffee Anticoagulation Monitoring Journal of Pharmacy Practice, October 1, 2004; 17(5): 317 - 326. [Abstract] [PDF] |
||||
![]() |
P. K. Neema, P. K. Sinha, and R. C. Rathod Activated Clotting Time During Cardiopulmonary Bypass: Is Repetition Necessary During Open Heart Surgery? Asian Cardiovasc Thorac Ann, March 1, 2004; 12(1): 47 - 52. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. J. Santrach Devices for Monitoring Heparin and Protamine in the Operating Room Seminars in Cardiothoracic and Vascular Anesthesia, December 1, 2003; 7(4): 379 - 385. [Abstract] [PDF] |
||||
![]() |
W. C. Oliver Jr Overview of Heparin and Protamine Management and Dosing Regimens in Pediatric Cardiac Surgical Patients Seminars in Cardiothoracic and Vascular Anesthesia, December 1, 2003; 7(4): 387 - 410. [Abstract] [PDF] |
||||
![]() |
P D Raymond, M J Ray, S N Callen, and N A Marsh Heparin monitoring during cardiac surgery. Part 1: validation of whole-blood heparin concentration and activated clotting time Perfusion, September 1, 2003; 18(5): 269 - 276. [Abstract] [PDF] |
||||
![]() |
P D Raymond, M J Ray, S N Callen, and N A Marsh Heparin monitoring during cardiac surgery. Part 2: calculating the overestimation of heparin by the activated clotting time Perfusion, September 1, 2003; 18(5): 277 - 281. [Abstract] [PDF] |
||||
![]() |
T. W. Stief and J. Fareed Point of Care: Diagnostics in Hemostasisthe Wrong Direction? Clinical and Applied Thrombosis/Hemostasis, July 1, 2003; 9(3): 191 - 195. [Abstract] [PDF] |
||||
![]() |
J. D. Marmur, S. X. Anand, R. S. Bagga, J. Fareed, C.-M. Pan, S. K. Sharma, and M. F. Richard The activated clotting time can be used to monitor the low molecular weight heparin dalteparin after intravenous administration J. Am. Coll. Cardiol., February 5, 2003; 41(3): 394 - 402. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Bailey, K. A. Tanaka, and J. H. Levy Cardiac Surgical Pharmacology Card. Surg. Adult, January 1, 2003; 2(2003): 85 - 118. [Full Text] |
||||
![]() |
L. H. Edmunds Jr. and R. W. Colman Extracorporeal Circulation: Thrombosis and Bleeding Card. Surg. Adult, January 1, 2003; 2(2003): 338 - 348. [Full Text] |
||||
![]() |
D. Giavarina, M. Carta, A. Fabbri, J. Manfredi, E. Gasparotto, and G. Soffiati Monitoring high-dose heparin levels by ACT and HMT during extracorporeal circulation: diagnostic accuracy of three compact monitors Perfusion, January 1, 2002; 17(1): 23 - 26. [Abstract] [PDF] |
||||
![]() |
J. H. Levy Pharmacologic preservation of the hemostatic system during cardiac surgery Ann. Thorac. Surg., November 1, 2001; 72(5): S1814 - 1820. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. J. Despotis, M. S. Avidan, and C. W. Hogue Jr Mechanisms and attenuation of hemostatic activation during extracorporeal circulation Ann. Thorac. Surg., November 1, 2001; 72(5): S1821 - 1831. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Shore-Lesserson Monitoring the Hematologic Complications of Cardiopulmonary Bypass Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2001; 5(3): 207 - 216. [Abstract] [PDF] |
||||
![]() |
G. J. Despotis, C. W. Hogue, R. Saleem, M. Bigham, N. Skubas, I. Apostolidou, A. Qayum, and J. H. Joist The Relationship Between Hirudin and Activated Clotting Time: Implications for Patients with Heparin-Induced Thrombocytopenia Undergoing Cardiac Surgery Anesth. Analg., July 1, 2001; 93(1): 28 - 32. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. M. Ambrose, C. A. Parvin, E. Mendeloff, and L. Luchtman-Jones Evaluation of the TAS Analyzer and the Low-Range Heparin Management Test in Patients Undergoing Extracorporeal Membrane Oxygenation Clin. Chem., May 1, 2001; 47(5): 858 - 866. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Codispoti, C. A. Ludlam, D. Simpson, and P. S. Mankad Individualized heparin and protamine management in infants and children undergoing cardiac operations Ann. Thorac. Surg., March 1, 2001; 71(3): 922 - 927. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Leyvi, L. Shore-Lesserson, D. Harrington, F. Vela-Cantos, and S. Hossain An Investigation of a New Activated Clotting Time ""MAX-ACT"" in Patients Undergoing Extracorporeal Circulation Anesth. Analg., March 1, 2001; 92(3): 578 - 583. [Abstract] [Full Text] [PDF] |
||||
![]() |
C Gruenwald, V de Souza, A K. Chan, and M Andrew Whole blood heparin concentrations do not correlate with plasma antifactor Xa heparin concentrations in pediatric patients undergoing cardiopulmonary bypass Perfusion, May 1, 2000; 15(3): 203 - 209. [Abstract] [PDF] |
||||
![]() |
L. Shore-Lesserson, H. E. Manspeizer, M. Bolastig, D. Harrington, F. Vela-Cantos, and M. DePerio Anticoagulation for Cardiac Surgery in Patients Receiving Preoperative Heparin: Use of the High-Dose Thrombin Time Anesth. Analg., April 1, 2000; 90(4): 813 - 818. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. I. Flom-Halvorsen, E. Ovrum, M. Abdelnoor, S. Bjornsen, and F. Brosstad Assessment of heparin anticoagulation: comparison of two commercially available methods Ann. Thorac. Surg., April 1, 1999; 67(4): 1012 - 1016. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. P. Bidstrup Ann. Thorac. Surg., April 1, 1999; 67(4): 1016 - 1017. [Full Text] [PDF] |
||||
![]() |
N. Ramamurthy, N. Baliga, J. A. Wahr, U. Schaller, V. C. Yang, and M. E. Meyerhoff Improved protamine-sensitive membrane electrode for monitoring heparin concentrations in whole blood via protamine titration§ Clin. Chem., March 1, 1998; 44(3): 606 - 613. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. J. Despotis, J. H. Joist, and L. T. Goodnough Monitoring of hemostasis in cardiac surgical patients: impact of point-of-care testing on blood loss and transfusion outcomes Clin. Chem., September 1, 1997; 43(9): 1684 - 1696. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. J. Despotis, J. H. Joist, L. T. Goodnough, S. A. Santoro, and E. Spitznagel WHOLE BLOOD HEPARIN CONCENTRATION MEASUREMENTS BY AUTOMATED PROTAMINE TITRATION AGREE WITH PLASMA ANTI-XA MEASUREMENTS J. Thorac. Cardiovasc. Surg., March 1, 1997; 113(3): 611 - 613. [Full Text] |
||||
![]() |
J.-F. Hardy, S. Belisle, D. Robitaille, J. Perrault, M. Roy, and L. Gagnon MEASUREMENT OF HEPARIN CONCENTRATION IN WHOLE BLOOD WITH THE HEPCON/HMS DEVICE DOES NOT AGREE WITH LABORATORY DETERMINATION OF PLASMA HEPARIN CONCENTRATION USING A CHROMOGENIC SUBSTRATE FOR ACTIVATED FACTOR X J. Thorac. Cardiovasc. Surg., July 1, 1996; 112(1): 154 - 161. [Abstract] [Full Text] |
||||
![]() |
G. J. Despotis, J. H. Joist, C. W. Hogue Jr., A. Alsoufiev, K. Kater, L. T. Goodnough, S. A. Santoro, E. Spitznagel, M. Rosenblum, and D. G. Lappas The impact of heparin concentration and activated clotting time monitoring on blood conservation: A prospective, randomized evaluation in patients undergoing cardiac operation J. Thorac. Cardiovasc. Surg., July 1, 1995; 110(1): 46 - 54. [Abstract] [Full Text] |
||||
![]() |
G. J. Despotis, J. H. Joist, D. Joiner-Maier, A. L. Alsoufiev, A. N. Triantafillou, L. T. Goodnough, S. A. Santoro, and D. G. Lappas Effect of Aprotinin on Activated Clotting Time, Whole Blood and Plasma Heparin Measurements Ann. Thorac. Surg., January 1, 1995; 59(1): 106 - 111. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |