JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Yasuharu Imai
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Beppu, T.
Right arrow Articles by Fukui, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Beppu, T.
Right arrow Articles by Fukui, Y.

J Thorac Cardiovasc Surg 1995;109:428-438
© 1995 Mosby, Inc.


CARDIOPULMONARY BYPASS,
MYOCARDIAL MANAGEMENT, AND SUPPORT TECHNIQUES

A computerized control system for cardiopulmonary bypass

Toshiyuki Beppu, MEa, Yasuharu Imai, MDa, Yasuhiro Fukui, PhDb


Tokyo, Japan

Supported in part by Grant-in-Aid for Scientific Research from the Ministry of Education, Science, and Culture of Japan.

Received for publication Dec. 23, 1993. Accepted for publication June 16, 1994. Address for reprints: Toshiyuki Beppu, ME, The Heart Institute of Japan, Tokyo Women's Medical College, 8-1 Kawadacho Shinjuku-ku, Tokyo 162, Japan.

Abstract

A pump control system using a microcomputer for cardiopulmonary bypass has been developed. The parameters monitored by the computer are central venous pressure, aortic pressure, blood volume in a reservoir, and collapsing of a small vinyl bag in a venous withdrawal tube. Both pumps in the arterial infusion and the venous withdrawal lines are automatically controlled through an interface unit throughout cardiopulmonary bypass. The system regulates central venous pressure with a proportional-integral control algorithm to maintain intravascular volume constant. A screening algorithm is devised to remove artifacts introduced to the pressure measurement. During the weaning period, a perfusionist can select either the central venous pressure control or a reservoir blood volume control. Computerized pump perfusion was applied on 15 children during cardiac operations. Perfusion flow and central venous pressure were controlled satisfactorily with stable operation. Compared with conventional manually controlled pump perfusion, no significant difference was noted in mean aortic pressure, central venous pressure, net fluid balance, total urination, blood chemistry, and urinalysis. This system is useful and is expected to improve the safety of pump perfusion. (J THORAC CARDIOVASC SURG1995; 109: 428-38)




This article has been cited by other articles:


Home page
Card Surg AdultHome page
J. W. Hammon
Extracorporeal Circulation: Perfusion System
Card. Surg. Adult, January 1, 2008; 3(2008): 350 - 370.
[Full Text]


Home page
Card Surg AdultHome page
E. A. Hessel II and L. H. Edmunds Jr.
Extracorporeal Circulation: Perfusion Systems
Card. Surg. Adult, January 1, 2003; 2(2003): 317 - 338.
[Full Text]


Home page
PerfusionHome page
M. Kurusz, B. D Butler, J. Katz, and V. R Conti
Air embolism during cardiopulmonary bypass
Perfusion, November 1, 1995; 10(6): 361 - 391.
[PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1995 by The American Association for Thoracic Surgery.