JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Joseph LoCicero, III
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sasaki, S.
Right arrow Articles by LoCicero, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sasaki, S.
Right arrow Articles by LoCicero, J., III

J Thorac Cardiovasc Surg 1995;109:1090-1096
© 1995 Mosby, Inc.


CARDIAC AND PULMONARY REPLACEMENT

Impact of initial flush potassium concentration on the adequacy of lung preservation

Shigeyuki Sasaki, MD, PhD (by invitation), James D. McCully, PhD (by invitation), Francesca Alessandrini, BS (by invitation), Joseph LoCicero, III, MD, FACS


Boston, Mass.

From the Division of Cardiothoracic Surgery, New England Deaconess Hospital, Harvard Medical School, Boston, Mass.

Address for reprints: Joseph LoCicero III, MD, Chief, Division of General Thoracic Surgery, New England Deaconess Hospital, Harvard Medical School, 110 Francis St., No. 2C, Boston, MA 02215.

Abstract

The effects of initial lung flushing with intracellular and extracellular fluid type solutions were studied in lungs stored with the University of Wisconsin solution. Excised Sprague-Dawley rat lungs (n = 39) were flushed first with one of the following solutions: (1) the University of Wisconsin solution (K+ = 140 mmol/L), (2) modified (low potassium) University of Wisconsin solution (K+ = 20 mmol/L), (3) phosphate buffered saline solution (K+ = 3.9 mmol/L), (4) modified low-potassium phosphate-buffered saline solution (K+ = 20 mmol/L), (5) modified high-potassium phosphate-buffered saline solution (K+ = 40 mmol/L), and (6) Euro-Collins solution (K+ = 115 mmol/L) followed by secondary flush with storage solution and cold (4° C) storage in University of Wisconsin solution for 24 hours. The lungs were then reperfused in the isolated, pulsatile, blood-perfused working lung system for 2 hours or until lung failure. Blood gas analysis and shunt fraction, aerodynamic parameters (airway resistance, lung compliance, elastic work, and flow resistive work), and total pulmonary vascular resistance were measured throughout the perfusion period. The mean oxygen tensions (in millimeters of mercury) at 30 minutes after the onset of reperfusion for University of Wisconsin solution, modified University of Wisconsin solution, phosphate-buffered saline solution, modified phosphate-buffered saline solutions (20 and 40 mmol/L), and Euro-Collins solution were 56.1 ± 4.2, 72.7 ± 9.1, 87.7 ± 6.9 (p < 0.01 versus University of Wisconsin solution; p < 0.01 versus Euro-Collins solution), 86.0 ± 9.6 (p < 0.01 versus University of Wisconsin solution; p < 0.01 versus Euro-Collins solution), 87.9 ± 7.7 (p < 0.01 versus University of Wisconsin solution; p < 0.01 versus Euro-Collins solution), and 53.5 ± 6.0, respectively. All aerodynamic parameters in the lungs flushed with extracellular fluid type solutions were superior to those flushed with intracellular fluid type solutions. We conclude that the efficacy of initial flushing was essential for successful lung preservation and that extracellular fluid type solutions were superior to intracellular fluid type solutions, at least for flushing the lung before storage with University of Wisconsin solution. Potassium concentration in flushing solution should be 20 mmol/L or less to obtain appropriate flushing and subsequent adequate distribution of the storage solution. (J THORAC CARDIOVASC SURG 1995;109:1090-6)




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
R. C. King, O. A. R. Binns, R. C. Kanithanon, P. E. Parrino, T. B. Reece, J. D. Maliszewskyj, K. S. Shockey, C. G. Tribble, and I. L. Kron
Acellular Low-Potassium Dextran Preserves Pulmonary Function After 48 Hours of Ischemia
Ann. Thorac. Surg., September 1, 1997; 64(3): 795 - 800.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1995 by The American Association for Thoracic Surgery.