|
|
||||||||
J Thorac Cardiovasc Surg 1995;110:111-118
© 1995 Mosby, Inc.
CARDIOPULMONARY BYPASS, |
Boston, Mass.
Supported by National Institutes of Health Trauma Center Grant No. 5P50-36428.
Received for publication May 30, 1994. Accepted for publication Dec. 8, 1994. Address for reprints: Douglas W. Wilmore, MD, Brigham and Women's Hospital, Surgical Metabolism and Nutrition, Thorn Research Building, 14th Floor, 20 Shattuck St., Boston, MA 02115.
Abstract
Excessive fluid accumulation is associated with increased morbidity and prolonged convalescence after cardiopulmonary bypass. However, water fluctuations are difficult to assess solely on the basis of changes in body weight and fluid balance. Bioelectric impedance analysis is a simple, rapid, noninvasive bedside technique that measures the resistance of the body to a weak alternating current (50 kHz). The change in resistance is inversely proportional to the change in total body water. To investigate the relationship between body weight, fluid balance, and resistance, 18 patients who had cardiopulmonary bypass (9 men, 9 women, aged 61 ± 3 years, weighing 80 ± 4 kg, with ejection fraction 54% ± 3% and bypass time 113 ± 8 minutes [mean plus or minus standard error of the mean]) were followed up for 7 postoperative days. Body weight, fluid balance, and whole body and regional resistance were determined at 24-hour intervals. In the immediate postoperative period, fluid retention was accurately detected by simultaneous measurements of weight gain and decreased resistance (p < 0.001). Both measurements detected the initiation of diuresis by postoperative day 2 (p < 0.01). Whole body resistance returned to baseline values by day 7 (p > 0.05), and body weight returned to baseline on day 4 (p > 0.05). Change in weight and change in whole body resistance were highly correlated with cumulative fluid balance (r = 0.84, p < 0.001, andr = -0.81, p < 0.001, respectively), and these two measures were also related to each other throughout the study (r = -0.89, p < 0.001). The initial change in resistance was the best measurement associated with postoperative outcome (p 0.01). The data suggest that the measurement of electric resistance across the body can accurately detect acute changes in total body water and in fluid redistribution through the body. However, determining the relative day-to-day change in whole body resistance seems more appropriate than calculating absolute fluid changes over time. Bioelectric impedance offers a simple, rapid, noninvasive method to monitor serial changes in total body water. This technique can be useful in situations in which rapid alterations in water compartments occur, and it may be useful in predicting outcome after cardiopulmonary bypass. (J THORACCARDIOVASCSURG1995;110:111-8)
This article has been cited by other articles:
![]() |
Y. Hamada, K. Kawachi, N. Tsunooka, Y. Nakamura, S. Takano, and H. Imagawa Capillary Leakage in Cardiac Surgery with Cardiopulmonary Bypass Asian Cardiovasc Thorac Ann, September 1, 2004; 12(3): 193 - 197. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. L. Ackland, D. Singh-Ranger, S. Fox, B. McClaskey, J. F. Down, D. Farrar, M. Sivaloganathan, and M. G. Mythen Assessment of preoperative fluid depletion using bioimpedance analysis Br. J. Anaesth., January 1, 2004; 92(1): 134 - 136. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Shum-Tim, C. I. Tchervenkov, E. Laliberte, A.-M. Jamal, T. Nimeh, C.-Y. Luo, B. Bittira, and A. Philip Timing of steroid treatment is important for cerebral protection during cardiopulmonary bypass and circulatory arrest: minimal protection of pump prime methylprednisolone Eur. J. Cardiothorac. Surg., July 1, 2003; 24(1): 125 - 132. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. A. DiMaria-Ghalili Changes in Nutritional Status and Postoperative Outcomes in Elderly CABG Patients Biol Res Nurs, October 1, 2002; 4(2): 73 - 84. [Abstract] [PDF] |
||||
![]() |
N. Ad, J. P. Suyderhoud, Y. D. Kim, M. A. Makary, K. W. DeGroot, H. C. Lue, E. A. Pirovic, W. Z. Duvall, and J. L. Cox Benefits of prophylactic continuous infusion of furosemide after the maze procedure for atrial fibrillation J. Thorac. Cardiovasc. Surg., February 1, 2002; 123(2): 232 - 236. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Simonardottir, B. Torfason, and J. Magnusson Is compartment pressure related to plasma colloid osmotic pressure, in patients during and after cardiac surgery? Perfusion, March 1, 2001; 16(2): 137 - 145. [Abstract] [PDF] |
||||
![]() |
T. Shin'oka, D. Shum-Tim, P. C. Laussen, S. M. Zinkovsky, H. G. W. Lidov, A. d. Plessis, and R. A. Jonas Effects of Oncotic Pressure and Hematocrit on Outcome After Hypothermic Circulatory Arrest Ann. Thorac. Surg., January 1, 1998; 65(1): 155 - 164. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. FCPS, A. Samenesco, D. Royston, and A. Rees Cardiopulmonary effects of 7.2% saline solution compared with gelatin infusion in the early postoperative period after coronary artery bypass grafting J. Thorac. Cardiovasc. Surg., January 1, 1998; 115(1): 178 - 189. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. O. Jacobs Bioelectrical Impedance Analysis: Implications for Clinical Practice Nutr Clin Pract, October 1, 1997; 12(5): 204 - 210. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |