JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
J. Ernesto Molina
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Molina, J. E.
Right arrow Articles by Adler, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Molina, J. E.
Right arrow Articles by Adler, S.

J Thorac Cardiovasc Surg 1995;110:258-264
© 1995 Mosby, Inc.


SURGERY FOR ACQUIRED HEART DISEASE

Crinkling of epicardial defibrillator patchesA common and serious problem

J. Ernesto Molina, MD, PhD, David G. Benditt, MD, Stuart Adler, MD


Minneapolis, Minn.

From the Departments of Surgery and Cardiology, University of Minnesota, Minneapolis, Minn.

Received for publication June 15, 1994. Accepted for publication Nov. 15, 1994. Address for reprints: J. Ernesto Molina, MD, University of Minnesota, Box 182, 420 Delaware St., S.E., Minneapolis, MN 55455.

Abstract

The durability and reliability of the implantable cardioverter-defibrillator epicardial patch systems have not been reported. In 128 consecutive patients such systems manufactured by Cardiac Pacemakers, Inc. (St. Paul, Minn.) or Medtronic, Inc. (Minneapolis, Minn.) were implanted with 100% follow-up to investigate the rate of patch crinkling and its consequences. A total of 122 patients survived the operation (operative mortality, 6 patients; 4.7%). Ninety-four patients received Cardiac Pacemakers, Inc. AICD patches and 28 received Medtronic PCD patches. Patients had chest x-ray studies every 3 to 6 months and function of the defibrillator was checked every 3 months. Late mortality occurred in 17 patients (13%) leaving a total of 105 long-term survivors (82%) to the present. Among 122 survivors, severe crinkling of the patches occurred in 48 patients—33 in the Cardiac Pacemakers, Inc. AICD group (36%) and 15 in the PCD group (54%)—within 2 years of the implant. Crinkling of patches caused not only malfunction of the system, but also cardiac pain in three patients. Crinkling occurred as early as 2 months after implant and progressed throughout the period of observation. Fourteen patients later required implant of an additional transvenous defibrillator because of failure of the epicardial system. The percentage of transvenous implantable cardioverter-defibrillator systems needed was higher for the Medtronic group (28%) than for the Cardiac Pacemakers, Inc. AICD group (6.3%). Both systems have shown an unacceptably high rate of patch crinkling that occurs in a relatively short time. There is no difference whether a thoracotomy or midline sternotomy is used or whether the patches are implanted intrapericardially or extrapericardially. The quest should continue for a better patch system design. (J THORAC CARDIOVASC SURG1995;110:258-64)




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
T.-Y. Hsia, S. M. Bradley, M. J. LaPage, S. Whelan, J. P. Saul, J. M. Ringewald, and J. H. Reed
Novel Minimally Invasive, Intrapericardial Implantable Cardioverter Defibrillator Coil System: A Useful Approach to Arrhythmia Therapy in Children
Ann. Thorac. Surg., April 1, 2009; 87(4): 1234 - 1239.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Suzuki, H. Watanabe, S. Yoshii, S. Kaga, Y. Honda, N. Ishikawa, and M. Matsumoto
Alternative Technique for Implanting an Implantable Cardioverter Defibrillator in Infants
Ann. Thorac. Surg., November 1, 2008; 86(5): 1701 - 1703.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Watanabe, J.-i. Hayashi, M. Haga, M. Saito, H. Suzuki, and S. Sato
Successful implantation of a cardioverter defibrillator in an infant
Ann. Thorac. Surg., December 1, 2001; 72(6): 2125 - 2127.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Mehmanesh, R. Bauernschmitt, and R. Lange
Pectoral implantation of single-lead implantable cardioverter-defibrillators in patients without transvenous access
Ann. Thorac. Surg., October 1, 1999; 68(4): 1426 - 1427.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
U. Wolfhard and F. H. Splittgerber
Intramural migration of implantable cardioverter-defibrillator patch
J. Thorac. Cardiovasc. Surg., March 1, 1996; 111(3): 681 - 681.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1995 by The American Association for Thoracic Surgery.