JTCS Click here to go to SJM website.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kato, J.
Right arrow Articles by Ito, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kato, J.
Right arrow Articles by Ito, T.

J Thorac Cardiovasc Surg 1996;111:630-636
© 1996 Mosby, Inc.


CARDIOPULMONARY BYPASS,
MYOCARDIAL MANAGEMENT, AND SUPPORT TECHNIQUES

CORONARY ARTERIAL PERFUSION DURING VENOARTERIAL EXTRACORPOREAL MEMBRANE OXYGENATION

Junji Kato, MD, Takahiko Seo, MD, PhD, Hisami Ando, MD, PhD, Hiroyuki Takagi, MD, PhD, Takahiro Ito, MD, PhD

Supported in part by a grant-in-Aid for Scientific Research (6348039, 2557053) from the Japanese Ministry of Education, Science, and Culture.

Received for publication March 8, 1995 Accepted for publication June 28, 1995. Address for reprints: Takahiro Ito, MD, Department of Surgery, Branch Hospital, Nagoya University School of Medicine, Daikohminami 1-1-20, Higashi-ku, Nagoya 461, Japan.

Abstract

The effects of venoarterial extracorporeal membrane oxygenation on left ventricular performance have not been studied in detail. Coronary arterial flow obtained by direct measurement with an electromagnetic flowmeter and blood gas analysis from the aortic root were tabulated during venoarterial extracorporeal membrane oxygenation in 14 puppies, and these parameters were evaluated with respect to changes in the venoarterial extracorporeal membrane oxygenation flow. Unique automatic blood pumps generating pulsatile flow were used for the venoarterial extracorporeal membrane oxygenation bypass. Coronary arterial flow decreased as the extracorporeal membrane oxygenation flow increased (106 ± 26 ml/min per 100 gm of left ventricle at 20 ml · min-1 · kg bypass flow to 71 ± 17 ml/min per 100 gm of left ventricle at 100 ml · min-1· kg bypass flow, p < 0.01). There were no significant changes in the mean or diastolic pressures in the ascending aorta despite changes in the extracorporeal membrane oxygenation flow. Arterial oxygen tension in the ascending aorta was not increased even under high-flow venoarterial extracorporeal membrane oxygenation. This result indicates that oxygenated blood from the extracorporeal membrane oxygenation circuit does not pass in a retrograde fashion into the aortic root and thus does not perfuse the coronary arteries. The diastolic aortic pressure did not correlate with the changes in extracorporeal membrane oxygenation flow. The decrease in coronary arterial flow is therefore predominantly caused by increased coronary arterial resistance. Tension-time index, an indicator of myocardial oxygen consumption, did not decrease with venoarterial extracorporeal membrane oxygenation. In conclusion, high-flow venoarterial extracorporeal membrane oxygenation causes undesirable hemodynamic effects on the left ventricle. (J THORAC CARDIOVASC SURG 1996;111:630-6)




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
B. W. Duncan
Mechanical circulatory support for infants and children with cardiac disease
Ann. Thorac. Surg., May 1, 2002; 73(5): 1670 - 1677.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1996 by The American Association for Thoracic Surgery.