|
|
||||||||
J Thorac Cardiovasc Surg 1996;112:33-37
© 1996 Mosby, Inc.
SURGERY FOR CONGENITAL HEART DISEASE |
From The Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada.
Received for publication Oct. 9, 1995 revisions requested Dec. 4, 1995; revisions received Jan. 4, 1995 Accepted for publication Jan. 9, 1995. Address for reprints: Christine Boutin, MD, Division of Cardiology, The Hospital for Sick Children, 555 University Ave., Toronto, Ontario, Canada M5G 1X8.
Abstract
In the surgical repair of tetralogy of Fallot, monocuspid valves are sometimes inserted within a transannular patch to prevent pulmonary insufficiency. To determine whether this monocuspid valve prevents short-term postoperative pulmonary insufficiency and improves clinical outcome, we reviewed clinical data and preoperative and postoperative echocardiographic variables from 61 patients who underwent one of three different procedures for repair of tetralogy of Fallot between August 1992 and March 1994. We compared features from 24 patients who had undergone transannular patch repair with a monocuspid valve (patch-valve) with those from 17 patients who had undergone patch repair without a monocuspid valve (patch) and 20 patients who had undergone repair without a transannular patch (no patch). We used the ratio of pulmonary valve insufficiency jet width to pulmonary artery diameter, as measured by color-flow Doppler flowmetry, as an index of severity of pulmonary insufficiency. Moderate to severe pulmonary insufficiency was arbitrarily defined as a ratio of at least 0.50. We found no significant differences in ratios among the patch-valve group (0.73 ± 0.25, mean ± standard deviation), the patch group (0.79 ± 0.20), and the no patch group (0.59 ± 0.23). The percentages of patients with moderate to severe pulmonary insufficiency did not differ among the three groups (patch-valve 80%, patch 90%, no patch 64%). Clinical data (including mortality, number of reoperations, intensive care unit and hospital lengths of stay, and postoperative hemodynamics) were similar in the three groups. We conclude that insertion of a monocuspid valve in repair of tetralogy of Fallot does not prevent short-term postoperative pulmonary insufficiency and does not improve immediate postoperative outcome for these patients. (J THORAC CARDIOVASC SURG 1996;112:33-7)
This article has been cited by other articles:
![]() |
G. R. Nunn, J. Bennetts, and E. Onikul Durability of hand-sewn valves in the right ventricular outlet. J. Thorac. Cardiovasc. Surg., August 1, 2008; 136(2): 290 - 296. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Anagnostopoulos, A. Azakie, S. Natarajan, N. Alphonso, M. M. Brook, and T. R. Karl Pulmonary valve cusp augmentation with autologous pericardium may improve early outcome for tetralogy of Fallot J. Thorac. Cardiovasc. Surg., March 1, 2007; 133(3): 640 - 647. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Khambadkone, L. Coats, A. Taylor, Y. Boudjemline, G. Derrick, V. Tsang, J. Cooper, V. Muthurangu, S. R. Hegde, R. S. Razavi, et al. Percutaneous Pulmonary Valve Implantation in Humans: Results in 59 Consecutive Patients Circulation, August 23, 2005; 112(8): 1189 - 1197. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.F. M. Bechtel, P. E. Lange, and H. H. Sievers Optimal Size of a Monocusp Patch for Reconstruction of a Hypoplastic Pulmonary Root: An Experimental Study in Pigs Ann. Thorac. Surg., June 1, 2005; 79(6): 2103 - 2108. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. A Vricella, S. R Gundry, H. Izutani, M. A Kuhn, N. Mulla, and L. L Bailey Fate of Polytetrafluoroethylene Monocusp Pulmonary Valves in an Animal Model Asian Cardiovasc Thorac Ann, December 1, 2003; 11(4): 280 - 284. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. C. Sung, S. Kim, J. S. Woo, and Y. S. Lee Pulmonic valve annular enlargement with valve repair in tetralogy of Fallot Ann. Thorac. Surg., January 1, 2003; 75(1): 303 - 305. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. T. Yilmaz, E. Ozal, C. Gunay, and H. Tatar Simultaneous enlargement of the pulmonaryannulus and the pulmonary cusp with atransannular patch J. Thorac. Cardiovasc. Surg., January 1, 2003; 125(1): 206 - 208. [Full Text] [PDF] |
||||
![]() |
M. W. Turrentine, R. P. McCarthy, P. Vijay, A. C. Fiore, and J. W. Brown Polytetrafluoroethylene monocusp valve technique for right ventricular outflow tract reconstruction Ann. Thorac. Surg., December 1, 2002; 74(6): 2202 - 2205. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. W. Turrentine, R. P. McCarthy, P. Vijay, K. W. McConnell, and J. W. Brown PTFE monocusp valve reconstruction of the right ventricular outflow tract Ann. Thorac. Surg., March 1, 2002; 73(3): 871 - 880. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. J. Kim, J.-J. Park, J. R. Lee, J. R. Rho, Y. S. Yun, J. Y. Choi, and C. I. Noh Modified Lecompte procedure for the anomalies of ventriculoarterial connection Ann. Thorac. Surg., July 1, 2001; 72(1): 176 - 180. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Rao, J. Ivanov, R. D. Weisel, G. Cohen, M. A. Borger, and D. A.G. Mickle Lactate release during reperfusion predicts low cardiac output syndrome after coronary bypass surgery Ann. Thorac. Surg., June 1, 2001; 71(6): 1925 - 1930. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Iemura, H. Oku, M. Otaki, and H. Kitayama Expanded polytetrafluoroethylene monocuspid valve for right ventricular outflow tract reconstruction Ann. Thorac. Surg., November 1, 2000; 70(5): 1511 - 1514. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Rao, M. Kadletz, L. K. Hornberger, R. M. Freedom, and M. D. Black Preservation of the pulmonary valve complex in tetralogy of Fallot: how small is too small? Ann. Thorac. Surg., January 1, 2000; 69(1): 176 - 179. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. K. Najm, G. S. Van Arsdell, S. Watzka, L. Hornberger, J. G. Coles, and W. G. Williams PRIMARY REPAIR IS SUPERIOR TO INITIAL PALLIATION IN CHILDREN WITH ATRIOVENTRICULAR SEPTAL DEFECT AND TETRALOGY OF FALLOT J. Thorac. Cardiovasc. Surg., December 1, 1998; 116(6): 905 - 913. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. R. Vogt, M. Genoni, A. Kunzli, and M. I. Turina Cryopreserved homograft monocusp valves for reconstruction of the right ventricular outflow tract J. Thorac. Cardiovasc. Surg., February 1, 1997; 113(2): 423 - 423. [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |