JTCS Tips for Better Browsing
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Hikaru Matsuda
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mizuta, T.
Right arrow Articles by Matsuda, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mizuta, T.
Right arrow Articles by Matsuda, H.

J Thorac Cardiovasc Surg 1997;113:830-835
© 1997 Mosby, Inc.


CARDIAC AND PULMONARY REPLACEMENT

INCREASED NITRIC OXIDE LEVELS IN EXHALED AIR OF RAT LUNG ALLOGRAFTS

Takatoshi Mizuta, MDa, Yoshitaka Fujii, MDa, Masato Minami, MDa, Satonori Tanaka, MDa, Tomoki Utsumi, MDa, Hiroaki Kosaka, MDb, Ryouta Shirakura, MDc, Hikaru Matsuda, MDa

Received for publication August 1, 1996 revisions requested Oct. 14, 1996; revisions received Nov. 13, 1996; accepted for publication Dec. 27, 1996. Address for reprints: Takatoshi Mizuta, MD, First Department of Surgery, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka, 565, Japan.

Abstract

In organ transplantation nitric oxide has been reported to be involved in allograft rejection. We examined in a rat lung transplantation model whether nitric oxide is overproduced in acute rejection and can be detected in exhaled air. Thirteen rat right lung transplants were separated into three groups: group 1 (n = 5), untreated allografts (Brown-Norway [RT1n] to Lewis [RT1l]); group 2 (n = 4), cyclosporine-treated allografts; and group 3 (n = 4), isografts (Lewis to Lewis). We examined exhaled nitric oxide levels with a chemiluminescence analyzer and chest roentgenograms on days 2 through 5. Histologic samples were obtained on days 3 and 5. On day 5, the recipients were killed and we measured exhaled nitric oxide from the right and left lungs separately. Blood samples were also obtained for measurement of serum nitrite/nitrate. The exhaled nitric oxide level in untreated allografts increased significantly from day 5 (63.9 ± 39.2 ppb, p = 0.0095) and was significantly higher than that in treated allografts (9.1 ± l.6 ppb) (p = 0.0085) and isografts (6.9 ± 0.5 ppb) (p = 0.0068). The nitric oxide level in untreated allografts (826.5 ± 416.1 ppb) was 75 times as high as that from the contralateral normal left lungs (11.2 ± 2.6 ppb) (p = 0.0118). The level of exhaled nitric oxide correlated significantly with the histologic rejection grade (p = 0.0001). There was no significant difference in the serum nitrite/nitrate levels between allografts and isografts. These data suggest that increased exhaled nitric oxide levels might reflect acute rejection in lung transplants.




This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
K. Ohmori, S.-i. Takeda, S. Miyoshi, M. Minami, S. Nakane, M. Ohta, Y. Sawa, and H. Matsuda
Attenuation of lung injury in allograft rejection using NF-{kappa}B decoy transfection--novel strategy for use in lung transplantation
Eur. J. Cardiothorac. Surg., January 1, 2005; 27(1): 23 - 27.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Hayashi, Y. Sawa, N. Fukuyama, H. Nakazawa, and H. Matsuda
Inducible nitric oxide production is an adaptation to cardiopulmonary bypass-induced inflammatory response
Ann. Thorac. Surg., July 1, 2001; 72(1): 149 - 155.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Itano, W. Zhang, J. H. Ritter, T. J. McCarthy, N. S. Yew, T. Mohanakumar, and G. A. Patterson
Endobronchial transfection of naked viral interleukin-10 gene in rat lung allotransplantation
Ann. Thorac. Surg., April 1, 2001; 71(4): 1126 - 1133.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
Y. Hayashi, Y. Sawa, M. Nishimura, S. J. Tojo, N. Fukuyama, H. Nakazawa, and H. Matsuda
P-selectin participates in cardiopulmonary bypass-induced inflammatory response in association with nitric oxide and peroxynitrite production
J. Thorac. Cardiovasc. Surg., September 1, 2000; 120(3): 558 - 565.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. J. Swanson, S. J. Mentzer, J. J. Reilly, R. Bueno, J. M. Lukanich, M. T. Jaklitsch, L. Kobzik, E. P. Ingenito, A. Fuhlbrigge, C. Donovan, et al.
SURVEILLANCE TRANSBRONCHIAL LUNG BIOPSIES: IMPLICATION FOR SURVIVAL AFTER LUNG TRANSPLANTATION
J. Thorac. Cardiovasc. Surg., January 1, 2000; 119(1): 27 - 38.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
B. N. Mora, C. H.R. Boasquevisque, G. Uy, T. J. McCarthy, M. J. Welch, M. Boglione, and G. A. Patterson
Exhaled nitric oxide correlates with experimental lung transplant rejection
Ann. Thorac. Surg., January 1, 2000; 69(1): 210 - 215.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1997 by The American Association for Thoracic Surgery.