JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Martin J. Elliott
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chow, G.
Right arrow Articles by Kirkham, F. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chow, G.
Right arrow Articles by Kirkham, F. J.

J Thorac Cardiovasc Surg 1997;114:568-577
© 1997 Mosby, Inc.


SURGERY FOR CONGENITAL HEART DISEASE

THE RELATION BETWEEN PUMP FLOW RATE AND PULSATILITY ON CEREBRAL HEMODYNAMICS DURING PEDIATRIC CARDIOPULMONARY BYPASS

Gabriel Chow , MRCPIa, Idris G. Roberts , BSca e, A. David Edwards , FRCPe, Adrian Lloyd-Thomas , FRCAb, Angie Wade , MScc, Martin J. Elliott , FRCSd, Fenella J. Kirkham , FRCPa

This work was funded by the British Heart Foundation. F.J.K. is funded by the Wellcome Trust.

Received for publication Sept. 23, 1996 revisions requested Nov. 19, 1997; revisions received April 30, 1997 accepted for publication May 2, 1997. Address for reprints: Fenella J. Kirkham, FRCP, Neurosciences Unit, Institute of Child Health (UCL), Mecklenburgh Square, London WC1N 2AP, United Kingdom.

Abstract

Objectives: Neurologic impairment, at least partly ischemic in origin, has been reported in up to 25% of infants undergoing cardiopulmonary bypass, with or without circulatory arrest. Controversy continues about the effect of pump flow, pulsatile or nonpulsatile, on the brain and in particular on cerebral blood flow. This study examines the relationship between pump flow rate and cerebral hemodynamics during pulsatile and nonpulsatile cardiopulmonary bypass. Method: Near-infrared spectroscopy was used to determine cerebral blood flow and cerebral blood volume (measured as concentration change) in a randomized crossover study. Pulsatile and nonpulsatile flow were used for six 5-minute intervals at each of three different pump flow rates (0.6, 1.2, and 2.4 L · m2 · min–1) in 40 patients, median age 2 months (range 2 weeks to 20 years 5 months). The relations between pulsatile flow, pump flow rate, cerebral blood flow, hemoglobin concentration change (cerebral blood volume), mean arterial pressure, arterial carbon dioxide tension, and hematocrit value were prospectively examined by means of multivariate analysis. Results: Cerebral blood flow decreased 36% per L · m–2 · min–1 decrease in pump flow rate and was associated with changes in mean arterial pressure but did not differ according to pulsatility. Change in hemoglobin concentration was unrelated to changes in pulsatility of pump flow. Conclusion: Cerebral blood flow is related to pump flow rate. Pulsatile flow delivered with a Stöckert pump does not increase cerebral blood flow or alter hemoglobin concentration during cardiopulmonary bypass in children.




This article has been cited by other articles:


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
D. D. Doblar
Intraoperative Transcranial Ultrasonic Monitoring for Cardiac and Vascular Surgery
Seminars in Cardiothoracic and Vascular Anesthesia, June 1, 2004; 8(2): 127 - 145.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
E. R. Stephenson Jr and J. L. Myers
Pediatric cardiopulmonary bypass
Ann. Thorac. Surg., December 1, 2001; 72(6): 2176 - 2177.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. H. Hovels-Gurich, M.-C. Seghaye, M. Sigler, F. Kotlarek, A. Bartl, J. Neuser, R. Minkenberg, B. J. Messmer, and G. von Bernuth
Neurodevelopmental outcome related to cerebral risk factors in children after neonatal arterial switch operation
Ann. Thorac. Surg., March 1, 2001; 71(3): 881 - 888.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Undar, T. Masai, S.-Q. Yang, J. Goddard-Finegold, O.H. Frazier, and C. D. Fraser Jr
Effects of perfusion mode on regional and global organ blood flow in a neonatal piglet model
Ann. Thorac. Surg., October 1, 1999; 68(4): 1336 - 1342.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
M. J Elliott
Recent advances in paediatric cardiopulmonary bypass
Perfusion, July 1, 1999; 14(4): 237 - 246.
[PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. Undar and C. D. Fraser Jr.
The relation between pump flow rate and pulsatility on cerebral hemodynamics during pediatric cardiopulmonary bypass
J. Thorac. Cardiovasc. Surg., September 1, 1998; 116(3): 530 - 531.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1997 by The American Association for Thoracic Surgery.