JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Christopher Lincoln
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chaturvedi, R. R.
Right arrow Articles by Shore, D. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chaturvedi, R. R.
Right arrow Articles by Shore, D. F.

J Thorac Cardiovasc Surg 1998;115:77-83
© 1998 Mosby, Inc.


SURGERY FOR CONGENITAL HEART DISEASE

Left ventricular dysfunction after open repair of simple congenital heart defects in infants and children: Quantitation with the use of a conductance catheter immediately after bypass

Rajiv R. Chaturvedi, MRCPa, Christopher Lincoln, FRCSb, John W. W. Gothard, FRCAc, Michael H. Scallan, FRCAc, Paul A. White, MSca, Andrew N. Redington, MD, FRCPa, Darryl F. Shore, FRCSb


From the Departments of Paediatric Cardiology,a Cardiac Surgery,b and Anaesthesia,c Royal Brompton Hospital, Imperial College of Science, Technology, and Medicine, London, United Kingdom.

This research was funded by the Scott Rhodes Research Fund and the Royal Brompton Hospital Clinical Research Committee.

Received for publication Oct. 23, 1996; revisions requested March 3, 1997; revisions received May 5, 1997; accepted for publication June 12, 1997. Address for reprints: Andrew N. Redington, MD, FRCP, Royal Brompton Hospital, Sydney Street, Chelsea, London SW3 6NP, United Kingdom.

Objective: Quantification of myocardial injury after the simplest pediatric operations by load-independent indices of left ventricular function, using conductance and Mikro-Tip pressure catheters (Millar Instruments, Inc., Houston, Tex.) inserted through the left ventricular apex.
Methods: Sixteen infants and children with intact ventricular septum undergoing cardiac operations had left ventricular function measured, immediately before and after bypass. Real-time pressure-volume loops were generated by conductance and Mikro-Tip pressure catheters placed in the long-axis via the left ventricular apex, and preload was varied by transient snaring of the inferior vena cava.
Results: Good quality pressure-volume loops were generated in 13 patients (atrial septal defects, n = 11; double-chambered right ventricle, n = 1; supravalvular aortic stenosis, n = 1; age 0.25 to 14.4 years, weight 3.1 to 46.4 kg). Their mean bypass time was 41 ± 14 minutes and mean aortic crossclamp time 27 ± 11 minutes. End-systolic elastance decreased by 40.7% from 0.34 ± 0.17 to 0.21 ± 0.15 mm Hg-1·ml-1·kg-1 (p < 0.001). There were no significant changes in the slope of the stroke work–end-diastolic volume relationship, end-diastolic elastance, time constant of isovolumic relaxation, and normalized values of the maxima and minima of the first derivative of developed left ventricular pressure.
Conclusion: Load-independent indices of left ventricular function can be derived from left ventricular pressure-volume loops generated by conductance and Mikro-Tip pressure catheters during the perioperative period in infants and children undergoing cardiac operations. Incomplete myocardial protection was demonstrated by a deterioration in systolic function after even short bypass and crossclamp times.

Ignorance of the cause of postoperative myocardial dysfunction in the immature heart is compounded by the incomplete myocardial protection afforded by current cardioplegic strategies. 1,5 Investigations of the mechanisms and treatment of postoperative ventricular dysfunction are hampered by use of nonspecific clinical end points as indirect estimates of ventricular function, for example, requirement for inotropic agents, duration of ventilation, intensive care unit stay, and mortality. These clinical indices are relatively insensitive to changes in ventricular function and necessitate large cohorts of patients to detect even major differences in outcome from differing myocardial protective strategies.

To measure left ventricular function optimally during the perioperative period, with its dramatic changes in loading conditions, necessitates the use of load-independent indices of systolic and diastolic function. In infants and children with an intact ventricular septum undergoing cardiac operations (mainly atrial septal defect closure), we report the changes in left ventricular function assessed from the pressure-volume plane with the use of a conductance catheter and Mikro-Tip pressure catheter (Millar Instruments, Inc., Houston, Tex). In animal and human studies the conductance catheter is placed in the long axis of the left ventricle, most commonly through the aortic valve, with the use of retrograde arterial cannulation or aortotomy. 6-11 This is clearly impractical in children undergoing bypass procedures, and in this study we report the first clinical use of custom-built miniature catheters placed in the same long axis, but via the left ventricular apex.




This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
M. M.H. Cheung, R. K. Kharbanda, I. E. Konstantinov, M. Shimizu, H. Frndova, J. Li, H. M. Holtby, P. N. Cox, J. F. Smallhorn, G. S. Van Arsdell, et al.
Randomized Controlled Trial of the Effects of Remote Ischemic Preconditioning on Children Undergoing Cardiac Surgery: First Clinical Application in Humans
J. Am. Coll. Cardiol., June 6, 2006; 47(11): 2277 - 2282.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S P Schoen, T Kittner, S Bohl, M U Braun, G Simonis, A Schmeisser, and R H Strasser
Transcatheter closure of atrial septal defects improves right ventricular volume, mass, function, pulmonary pressure, and functional class: a magnetic resonance imaging study
Heart, June 1, 2006; 92(6): 821 - 826.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
E. Eroglu, L. Herbots, J. Van Cleemput, W. Droogne, P. Claus, J. D'hooge, B. Bijnens, J. Vanhaecke, and G. R. Sutherland
Ultrasonic strain/strain rate imaging--a new clinical tool to evaluate the transplanted heart
Eur J Echocardiogr, June 1, 2005; 6(3): 186 - 195.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
B. S. Allen
Pediatric myocardial protection: Where do we stand?
J. Thorac. Cardiovasc. Surg., July 1, 2004; 128(1): 11 - 13.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Vogel, G. Derrick, P. A. White, S. Cullen, H. Aichner, J. Deanfield, and A. N. Redington
Systemic ventricular function in patients with transposition of the great arteries after atrial repair: a tissue Doppler and conductance catheter study
J. Am. Coll. Cardiol., January 7, 2004; 43(1): 100 - 106.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
V. A. Schroeder, J. M. Pearl, S. M. Schwartz, T. P. Shanley, P. B. Manning, and D. P. Nelson
Combined Steroid Treatment for Congenital Heart Surgery Improves Oxygen Delivery and Reduces Postbypass Inflammatory Mediator Expression
Circulation, June 10, 2003; 107(22): 2823 - 2828.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Caputo, P. Modi, H. Imura, A. Pawade, A. J. Parry, M-S. Suleiman, and G. D. Angelini
Cold blood versus cold crystalloid cardioplegia for repair of ventricular septal defects in pediatric heart surgery: a randomized controlled trial
Ann. Thorac. Surg., August 1, 2002; 74(2): 530 - 535.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. Tonkovic-Capin, G. J. Gross, Z. J. Bosnjak, J. S. Tweddell, C. M. Fitzpatrick, and J. E. Baker
Delayed cardioprotection by isoflurane: role of KATP channels
Am J Physiol Heart Circ Physiol, July 1, 2002; 283(1): H61 - H68.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
R Dhillon, M Josen, M Henein, and A Redington
Transcatheter closure of atrial septal defect preserves right ventricular function
Heart, May 1, 2002; 87(5): 461 - 465.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. Tatebe, M. J. Davies, V. T. Tsang, and M. J. Elliott
Perioperative monitoring of left ventricular contractility
J. Thorac. Cardiovasc. Surg., November 1, 2001; 122(5): 1036 - 1038.
[Full Text] [PDF]


Home page
CirculationHome page
H. Imura, M. Caputo, A. Parry, A. Pawade, G. D. Angelini, and M.-S. Suleiman
Age-Dependent and Hypoxia-Related Differences in Myocardial Protection During Pediatric Open Heart Surgery
Circulation, March 20, 2001; 103(11): 1551 - 1556.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. A. White, C. I. O. Brookes, H. Ravn, V. Hjortdal, R. R. Chaturvedi, and A. N. Redington
Validation and utility of novel volume reduction technique for determination of parallel conductance
Am J Physiol Heart Circ Physiol, January 1, 2001; 280(1): H475 - H482.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. T. Kronon, B. S. Allen, S. Rahman, T. Wang, N. A. Tayyab, K. S. Bolling, and M. N. Ilbawi
Reducing postischemic reperfusion damage in neonates using a terminal warm substrate-enriched blood cardioplegic reperfusate
Ann. Thorac. Surg., September 1, 2000; 70(3): 765 - 770.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
R R Chaturvedi, V E Hjortdal, E V Stenbog, H B Ravn, P White, T D Christensen, A B Thomsen, J Pedersen, K E Sorensen, and A N Redington
Inhibition of nitric oxide synthesis improves left ventricular contractility in neonatal pigs late after cardiopulmonary bypass
Heart, December 1, 1999; 82(6): 740 - 744.
[Abstract] [Full Text]


Home page
Eur. J. Cardiothorac. Surg.Home page
R. R. Chaturvedi, D. F. Shore, P. A. White, M. H. Scallan, J. W.W. Gothard, A. N. Redington, and C. Lincoln
Modified ultrafiltration improves global left ventricular systolic function after open-heart surgery in infants and children
Eur. J. Cardiothorac. Surg., June 1, 1999; 15(6): 742 - 746.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1998 by The American Association for Thoracic Surgery.