JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kawahara, F.
Right arrow Articles by Fujita, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kawahara, F.
Right arrow Articles by Fujita, N.

J Thorac Cardiovasc Surg 1999;118:361-366
© 1999 Mosby, Inc.


CARDIOPULMONARY SUPPORT AND PHYSIOLOGY

BALLOON PUMP–INDUCED PULSATILE PERFUSION DURING CARDIOPULMONARY BYPASS DOES NOT IMPROVE BRAIN OXYGENATION

Fuminori Kawahara, MDa, Yuji Kadoi, MDa, Shigeru Saito, MDa, Daisuke Yoshikawa, MDa, Fumio Goto, MDa, Nao Fujita, MDb

From the Department of Anesthesiology and Reanimatology,a Gunma University, School of Medicine, Gunma, Japan, and the Department of Anesthesiology,b Saitama Cardiovascular and Pulmonary Center, Saitama, Japan.

Address for reprints: Yuji Kadoi, MD, Department of Anesthesiology and Reanimatology, Gunma University, School of Medicine, 3-39-22, Showa-machi, Maebashi, Gunma 371-8511, Japan.

Background: Whether pulsatile flow offers substantial advantages for brain protection during cardiopulmonary bypass is controversial. The purpose of this study is to determine whether differences exist between pulsatile and nonpulsatile bypass concerning the effects on internal jugular venous saturation and on the state of regional cerebral oxygenation during normothermia.
Methods: Twenty-two patients undergoing elective coronary artery bypass grafting were randomly divided into 2 groups: group 1 (n = 11) received nonpulsatile perfusion during cardiopulmonary bypass and group 2 (n = 11) received pulsatile perfusion during bypass. We used an intra-aortic balloon pump to generate pulsatility. A spectrophotometric probe (INVOS 3100R, Somanetics, Troy, Mich) was used to assess the state of regional cerebral oxygenation. A 4F fiberoptic oximetry oxygen saturation catheter was inserted into the right jugular bulb to monitor jugular venous oxygen saturation. Hemodynamic variables, arterial and jugular venous blood gases, and regional cerebral oxygenation were measured at 7 times points.
Results: In both groups, jugular venous oxygen saturation decreased at the early stage of the cardiopulmonary bypass (P = .03). Five patients in group 1 and 6 in group 2 had a jugular venous oxygen saturation of less than 50%. In both groups, the regional cerebral oxygenation value decreased during cardiopulmonary bypass (P = .04).
Conclusions: The present results showed that pulsatility generated through the use of intra-aortic balloon pumping did not produce any beneficial effects on jugular venous oxygen saturation and regional cerebral oxygenation at normothermia.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
C. W. Hogue Jr, C. A. Palin, and J. E. Arrowsmith
Cardiopulmonary bypass management and neurologic outcomes: an evidence-based appraisal of current practices.
Anesth. Analg., July 1, 2006; 103(1): 21 - 37.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
D. D. Doblar
Intraoperative Transcranial Ultrasonic Monitoring for Cardiac and Vascular Surgery
Seminars in Cardiothoracic and Vascular Anesthesia, June 1, 2004; 8(2): 127 - 145.
[Abstract] [PDF]


Home page
Anesth. Analg.Home page
Y. Kadoi, S. Saito, F. Goto, and N. Fujita
Slow Rewarming Has No Effects on the Decrease in Jugular Venous Oxygen Hemoglobin Saturation and Long-Term Cognitive Outcome in Diabetic Patients
Anesth. Analg., June 1, 2002; 94(6): 1395 - 1401.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. Undar and C. D. Fraser Jr
Balloon pump-induced pulsatile perfusion during cardiopulmonary bypass does not improve brain oxygenation
J. Thorac. Cardiovasc. Surg., January 1, 2000; 119(1): 189 - 189.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1999 by The American Association for Thoracic Surgery.