JTCS Tips for Better Browsing
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ellis, J. T.
Right arrow Articles by Yoganathan, A. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ellis, J. T.
Right arrow Articles by Yoganathan, A. P.

J Thorac Cardiovasc Surg 2000;119:83-093
© 2000 Mosby, Inc.


SURGERY FOR ACQUIRED CARDIOVASCULAR DISEASE

A COMPARISON OF THE HINGE AND NEAR-HINGE FLOW FIELDS OF THE ST JUDE MEDICAL HEMODYNAMIC PLUS AND REGENT BILEAFLET MECHANICAL HEART VALVES

Jeffrey T. Ellis, PhDa, Ajit P. Yoganathan, PhDb

From the School of Mechanical Engineeringa and the School of Biomedical Engineering,b Georgia Institute of Technology, Atlanta, Ga.

Supported by a research contract with St Jude Medical, Inc. Partial funding was also provided by a grant through the Georgia Affiliate of the American Heart Association.

Address for reprints: Ajit P. Yoganathan, PhD, Associate Chair, School of Biomedical Engineering, Georgia Institute of Technology, 654 Cherry St, Atlanta, GA 30332-0535.

Objective: The most widely implanted prosthetic valves are the mechanical bileaflets, most of which have good forward flow hemodynamics. However, recent clinical experiences illustrate the importance of understanding the flow structures generated within the hinge. The purpose of this study was to evaluate the hinge-flow dynamics of two new variations of a 17-mm St Jude Medical bileaflet valve: the Hemodynamic Plus and the Regent (St Jude Medical, Inc, St Paul, Minn).
Methods: Clinical quality reproductions of the valves were manufactured with clear housings. Laser Doppler velocimetry velocity and turbulent shear stress measurements were conducted within the hinge and thumbnail regions of the valves.
Results: In the 17-mm Hemodynamic Plus hinge, a rotating flow structure developed in the inflow pocket during forward flow. During systole, velocities through the hinge pocket reached 0.70 m/s, and the turbulent shear stress reached 1000 dynes/cm2. In the thumbnail, forward flow velocities ranged from 1.4 m/s to 1.7 m/s. In the 17-mm Regent hinge, a rotating flow structure partially developed in the inflow pocket during forward flow. During systole, velocities through the hinge pocket reached 0.75 m/s, and the turbulent shear stress reached 1300 dynes/cm2. In the thumbnail, forward flow velocities ranged from 1.0 m/s to 1.3 m/s.
Conclusions: The active leaflet motion through the St Jude Medical hinge creates a washout pattern that restricts the persistence of stagnation zones and thus may be a contributing factor to its successful clinical performance. The hinge and thumbnail flow dynamics of the 17-mm Regent valve are at least equivalent to, and possibly superior to, those of the 17-mm Hemodynamic Plus valve.




This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. L. Thompson, C. E. Hamner, D. D. Potter, M. Lewin, T. M. Sundt, and H. V. Schaff
Melagatran for thromboprophylaxis after mechanical valve implantation: Results in a heterotopic porcine model
J. Thorac. Cardiovasc. Surg., August 1, 2007; 134(2): 359 - 365.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
C. Amarelli, A. Della Corte, G. Romano, G. Iasevoli, G. Dialetto, L. S. De Santo, M. De Feo, M. Torella, M. Scardone, and M. Cotrufo
Left ventricular mass regression after aortic valve replacement with 17-mm St Jude Medical mechanical prostheses in isolated aortic stenosis
J. Thorac. Cardiovasc. Surg., March 1, 2005; 129(3): 512 - 517.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. Saxena, J. Lemmon, J. Ellis, and A. Yoganathan
An in vitro assessment by means of laser Doppler velocimetry of the medtronic advantage bileaflet mechanical heart valve hinge flow
J. Thorac. Cardiovasc. Surg., July 1, 2003; 126(1): 90 - 98.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
H.-L. Leo, Z. He, J. T. Ellis, and A. P. Yoganathan
Microflow fields in the hinge region of the CarboMedics bileaflet mechanical heart valve design
J. Thorac. Cardiovasc. Surg., September 1, 2002; 124(3): 561 - 574.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Gelsomino, G. Morocutti, P. Da Col, R. Frassani, R. Carella, G. Minen, and U. Livi
Preliminary experience with the St. Jude Medical Regent mechanical heart valve in the aortic position: early in vivo hemodynamic results
Ann. Thorac. Surg., June 1, 2002; 73(6): 1830 - 1836.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2000 by The American Association for Thoracic Surgery.