J Thorac Cardiovasc Surg 2002;124:387-391
© 2002 The American Association for Thoracic Surgery
Cardiopulmonary Support and Physiology (CSP) |
From the Department for Thoracic and Cardiovascular Surgery, University Hospital J. W. Goethe, Frankfurt am Main, Germany.
Received for publication Nov 29, 2001. Revisions requested Dec 26, 2001; revisions received Jan 23, 2002. Accepted for publication Feb 3, 2002. Address for reprints: Sven Martens, MD, Klinikum der J. W. Goethe-Universität, Klinik für Thorax- Herz und thorakale Gefäßchirurgie, Theodor Stern Kai 7, D-60529 Frankfurt am Main, Germany (E-mail: martens.herz{at}gmx.de).
Background: Cardiac surgery is associated with an important risk of central or peripheral organ damage, attributed in part to air embolism from incompletely deaired cardiac chambers. Insufflation of carbon dioxide into the thoracic cavity is widely used for organ protection in cardiac surgery.
Methods: In patients operated on through a sternotomy, the gas was insufflated through a standard cardioplegia line (group I, n = 10) or a Jackson-Pratt drain (group II, n = 10), with flow rates of 2, 4, and 6 L/min. In patients undergoing mitral valve surgery through a right anterolateral minithoracotomy, application through a gas port (group III, n = 10) was compared with application through a Veress needle (group IV, n = 10). In groups I and IV measurements were repeated with a gauze sponge to divert the gas stream.
Results: At a flow of 2 L/min, carbon dioxide levels in the thoracic cavity reached 52% ± 30% in group I and increased to 81% ± 27% when a gauze sponge was used. In group II a level of 91% ± 5% was achieved. In minimally invasive procedures carbon dioxide levels reached 92% ± 6% in group III and 60% ± 25% in group IV without a gauze sponge and 97% ± 2% in group IV with a gauze sponge. Increasing flow rates from 2 to 6 L/min decreased carbon dioxide levels in the thoracic cavity. Arterial blood gas analysis did not reveal critical levels of partial pressure of carbon dioxide at any time.
Conclusions: For optimized carbon dioxide concentrations during cardiac procedures, jet effects in the thoracic cavity have to be avoided. The highest levels were achieved with infusion lines covered by a gauze sponge or a perforated drain for conventional operations and a sponge-covered Veress needle or a gas port for minimally invasive approaches.
This article has been cited by other articles:
![]() |
S. Martens, K. Neumann, C. Sodemann, H. Deschka, G. Wimmer-Greinecker, and A. Moritz Carbon Dioxide Field Flooding Reduces Neurologic Impairment After Open Heart Surgery Ann. Thorac. Surg., February 1, 2008; 85(2): 543 - 547. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Ak, T. Aybek, G. Wimmer-Greinecker, F. Ozaslan, F. Bakhtiary, A. Moritz, and S. Dogan Evolution of surgical techniques for atrial septal defect repair in adults: A 10-year single-institution experience J. Thorac. Cardiovasc. Surg., September 1, 2007; 134(3): 757 - 764. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. A. Murphy, J. S. Miller, D. A. Langford, and A. B. Snyder Endoscopic robotic mitral valve surgery J. Thorac. Cardiovasc. Surg., October 1, 2006; 132(4): 776 - 781. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Aybek, S. Dogan, P. S. Risteski, A. Zierer, T. Wittlinger, G. Wimmer-Greinecker, and A. Moritz Two hundred forty minimally invasive mitral operations through right minithoracotomy. Ann. Thorac. Surg., May 1, 2006; 81(5): 1618 - 1624. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Barnard and D. Speake In open heart surgery is there a role for the use of carbon dioxide field flooding techniques to reduce the level of post-operative gaseous emboli? Interactive CardioVascular and Thoracic Surgery, December 1, 2004; 3(4): 599 - 602. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Martens, A. Theisen, J. O. Balzer, M. Dietrich, K. Graubitz, M. Scherer, C. Schmitz, M. Doss, and A. Moritz Improved cerebral protection through replacement of residual intracavital air by carbon dioxide: A porcine model using diffusion-weighted magnetic resonance imaging J. Thorac. Cardiovasc. Surg., January 1, 2004; 127(1): 51 - 56. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. van der Linden and M. Persson A gauze sponge cannot act as a gas diffuser in cardiac surgery when it gets wet J. Thorac. Cardiovasc. Surg., May 1, 2003; 125(5): 1178 - 1179. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |