JTCS Click here to go to SJM website.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
David T. Lai
D. Craig Miller
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Timek, T. A.
Right arrow Articles by Miller, D. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Timek, T. A.
Right arrow Articles by Miller, D. C.
Related Collections
Right arrow Valve disease

J Thorac Cardiovasc Surg 2002;124:541-552
© 2002 The American Association for Thoracic Surgery


Surgery for Acquired Cardiovascular Disease (ACD)

Hemodynamic performance of an unstented xenograft mitral valve substitute

Tomasz A. Timek, MDa, David T. Lai, FRACSa, Frederick A. Tibayan, MDa, Paul Dagum, MD, PhDa, George T. Daughters, MSa,b, David Liang, MD, PhDc, Neil B. Ingels, Jr, PhDa,b, D. Craig Miller, MDa

From the Department of Cardiovascular and Thoracic Surgerya and the Division of Cardiovascular Medicine,c Stanford University School of Medicine, Stanford, Calif, and the Laboratory of Cardiovascular Physiology and Biophysics,b Research Institute of the Palo Alto Medical Foundation, Palo Alto, Calif.

Supported by grants HL-29589 and HL-67025 from the National Heart, Lung, and Blood Institute and a contract from Medtronic Heart Valve Division, Minneapolis, Minn. Drs Timek, Tibayan, Dagum, and Lai are Carl and Leah McConnell Cardiovascular Surgical Research Fellows. Drs Timek and Dagum were supported by NHLBI Individual Research Service Awards HL-10452 and HL-10000. Dr Timek is also a recipient of the Thoracic Surgery Foundation Research Fellowship Award. Dr Lai was supported by a fellowship from the American Heart Association, Western States Affiliate.

Read at the Twenty-seventh Annual Meeting of The Western Thoracic Surgical Association, San Diego, Calif, June 20-23, 2001.

Received for publication June 28, 2001. Revisions requested Sept 19, 2001; revisions received Jan 4, 2002. Accepted for publication Feb 18, 2002. Address for reprints: D. Craig Miller, MD, Department of Cardiovascular Surgery, Falk Cardiovascular Research Center, Stanford University School of Medicine, Stanford, CA 94305-5247 (E-mail: dcm{at}stanford.edu).

Objective: Stentless mitral xenografts offer potential clinical benefits because they mimic the normal bileaflet mitral valve. How best to implant them and their hemodynamic performance and durability, however, remain unknown.
Methods: A stentless porcine mitral xenograft valve (Medtronic physiologic mitral valve) was implanted in 7 sheep with papillary muscle sewing tubes attached with transmural left ventricular sutures. Radiopaque markers were inserted on the leaflets, annular cuff, papillary tips, and left ventricle. After 10 ± 5 days, the animals were studied with biplane videofluoroscopy to determine 3-dimensional marker coordinates at baseline and during dobutamine infusion. Transesophageal echocardiography assessed mitral regurgitation and valvular gradients. Mitral annular area was calculated from the annular markers. Physiologic mitral valve leaflet and annular dynamics were compared with 8 native sheep valves.
Results: Average mitral regurgitation grade at baseline was 1.2 ± 1.0 (range, 0-4), and the mean transvalvular pressure gradients were 3.6 ± 1.3 and 6.2 ± 2.2 mm Hg during baseline and dobutamine infusion, respectively. Xenograft mitral annular area contraction throughout the cardiac cycle was reduced (6% ± 6% vs 13% ± 4% for physiologic mitral valve and control valve, respectively; P = .03). Physiologic mitral valve leaflet geometry during closure differed from the native valve, with the anterior leaflet being convex to the atrium and with little motion of the posterior leaflet. Three animals survived more than 3 months; good healing of the annular cuff and papillary muscle tubes was demonstrated.
Conclusion: This stentless xenograft mitral valve substitute had low gradients at baseline and during stress conditions early postoperatively, with mild mitral regurgitation. Preliminary analysis of healing characteristics appeared favorable at 3 months. Additional studies are needed to determine long-term xenograft mitral valve performance and resistance to calcification.




This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. W.M. Frater
Stentless mitral valves
J. Thorac. Cardiovasc. Surg., April 1, 2007; 133(4): 861 - 864.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. L. Navia, K. Doi, F. A. Atik, K. Fukamachi, M. W. Kopcak Jr, R. Dessoffy, P. Ruda-Vega, M. Garcia, P. L. Houghtaling, M. Martin, et al.
Acute in vivo evaluation of a new stentless mitral valve
J. Thorac. Cardiovasc. Surg., April 1, 2007; 133(4): 986 - 994.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 by The American Association for Thoracic Surgery.