|
|
||||||||
J Thorac Cardiovasc Surg 2003;125:71-78
© 2003 The American Association for Thoracic Surgery
Surgery for Congenital Heart Disease (CHD) |
From the Department of Cardiovascular Surgery, The University of Tokushima School of Medicine, Tokushima, Japan.
Received for publication Jan 24, 2002. Accepted for publication May 15, 2002. Address for reprints: Tetsuya Kitagawa, MD, Department of Cardiovascular Surgery, The University of Tokushima School of Medicine, Kuramoto, Tokushima 770-8503, Japan (E-mail: kitagawa{at}clin.med.tokushima-u.ac.jp).
Objective: We examined the influence of shunt size on regulation of the pulmonary blood flow in a canine model of a univentricular heart because specific guidelines regarding suitable shunt size in the Norwood operation remain undetermined.
Methods: Beagle dogs (n = 8) 3 to 7 months old and weighing 3.0 to 5.0 kg were used. Atrial septectomy and patch closure of the tricuspid valve were performed, and a systemic-pulmonary arterial shunt was created by interposing a 3.5- or 4.0-mm graft between the right subclavian artery and main pulmonary artery. After cardiopulmonary bypass, hemodynamic variables including pulmonary and systemic blood flow were measured consecutively according to physiologically respiratory manipulations. The ratio of shunt size to body weight ranged from 0.80 to 1.33 mm/kg (1.08 ± 0.16 mm/kg).
Results: Each dog with a ratio of shunt size to body weight of 0.8 to 1.1 showed significant negative correlation between the pulmonary/systemic blood flow ratio and arterial PCO2, but those with a ratio of shunt size to body weight of 1.1 to 1.4 did not. Consequently each dog with a ratio of shunt size to body weight of 0.8 to 1.0 got adequate systemic flow, whereas a ratio of 1.0 to 1.4 resulted in inadequate systemic flow and acidic status. Similar phenomena were shown with the grouped data on relationship between the pulmonary/systemic blood flow ratio and inspired oxygen fraction.
Conclusions: These findings imply that when the ratio of shunt size to body weight is 0.8 to 1.1, the pulmonary/systemic blood flow ratio is controllable by physiologic respiratory manipulations. Larger shunts make pulmonary blood flow excessive and uncontrollable. We recommend that a ratio of shunt size to body weight of 0.9 to 1.0 be considered a useful index for suitable systemic-pulmonary arterial shunt in the Norwood operation.
This article has been cited by other articles:
![]() |
S. Mohammadi, O. Benhameid, A. Campbell, J. Potts, J. Joza, H. Al-Habib, S. Sett, and J. Le Blanc Could we still improve early and interim outcome after prosthetic systemic-pulmonary shunt? A risk factors analysis Eur. J. Cardiothorac. Surg., September 1, 2008; 34(3): 545 - 549. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Li, G. Zhang, B. W. McCrindle, H. Holtby, T. Humpl, S. Cai, C. A. Caldarone, A. N. Redington, and G. S. Van Arsdell Profiles of hemodynamics and oxygen transport derived by using continuous measured oxygen consumption after the Norwood procedure J. Thorac. Cardiovasc. Surg., February 1, 2007; 133(2): 441 - 448. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Li, G. Zhang, H. M. Holtby, B. W. McCrindle, S. Cai, T. Humpl, C. A. Caldarone, W. G. Williams, A. N. Redington, and G. S. Van Arsdell Inclusion of oxygen consumption improves the accuracy of arterial and venous oxygen saturation interpretation after the Norwood procedure J. Thorac. Cardiovasc. Surg., May 1, 2006; 131(5): 1099 - 1107. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Karamlou, D. A. Ashburn, C. A. Caldarone, E. H. Blackstone, R. A. Jonas, M. L. Jacobs, W. G. Williams, R. M. Ungerleider, B. W. McCrindle, and for the Members of the Congenital Heart Surgeons' Matching procedure to morphology improves outcomes in neonates with tricuspid atresia J. Thorac. Cardiovasc. Surg., December 1, 2005; 130(6): 1503 - 1510. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Ricci, P. Lombardi, A. Galindo, A. Vasquez, J. Zuccarelli, and E. Rosenkranz Distribution of cardiac output and oxygen delivery in an acute animal model of single-ventricle physiology J. Thorac. Cardiovasc. Surg., October 1, 2005; 130(4): 1062 - 1070. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Ricci, P. Lombardi, A. Galindo, E. Coscarella, A. Vasquez, and E. Rosenkranz Single-Ventricle Physiology Reduces Cerebral Oxygen Delivery in a Piglet Model Ann. Thorac. Surg., August 1, 2005; 80(2): 686 - 694. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. C. De Oliveira, D. A. Ashburn, F. Khalid, H. M. Burkhart, I. T. Adatia, H. M. Holtby, W. G. Williams, and G. S. Van Arsdell Prevention of Early Sudden Circulatory Collapse After the Norwood Operation Circulation, September 14, 2004; 110(11_suppl_1): II-133 - II-138. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |