Received for publication July 10, 2002. Revisions requested Aug 19, 2002; revisions received Oct 7, 2002. Accepted for publication Oct 18, 2002. Address for reprints: Robert J. Cerfolio, MD, Associate Professor of Surgery, Division of Cardiothoracic Surgery, University of Alabama at Birmingham, 1900 University Blvd, THT 712, Birmingham, AL 35294 (E-mail: Robert.cerfolio{at}ccc.uab.edu).
Objectives: Surgical resection after preoperative chemotherapy in patients with non-small cell lung cancer might only be best for patients who are responders. We compared positron emission tomographic scanning with 2-fluoro-2-deoxy-D-glucose (FDP-PET scanning) with computed tomographic scanning to evaluate their ability to predict this response for the primary tumor, N1 and N2 lymph nodes.
Methods: All patients with non-small cell lung cancer who had an initial FDP-PET scan staging with tissue biopsy, neoadjuvant chemotherapy, repeat FDP-PET scanning, and repeat biopsies were prospectively studied.
Results: There were 34 patients (24 men; median age, 64 years). Eleven patients had N2 disease, and 7 had N1 disease. Twenty-seven patients received chemotherapy, and 7 patients received chemotherapy and radiation. All but 9 patients underwent resection. Statistical analysis showed FDP-PET scanning to be more specific (P < .0001), to have a higher positive predictive value (P = .0018), and to have a higher negative predictive value (P < .0001) than computed tomographic scanning for predicting residual tumor at the primary site. FDP-PET scanning was more sensitive (P < .0001) and more accurate (P < .0001), had a higher positive predictive value (P < .0001), and had a higher negative predictive value (P = .0002) than computed tomographic scanning for paratracheal nodes (number 2 and 4 lymph nodes). FDP-PET scanning had a higher positive predictive value (P < .0001) than computed tomographic scanning for the other N2 (numbers 5, 6, 7, 8, and 9) lymph nodes.
Conclusions: Repeat FDP-PET scanning is more specific and has a higher positive predictive value and negative predictive value than computed tomographic scanning for detecting residual tumor in the lung in patients with non-small cell lung cancer who have received preoperative chemotherapy. It is more sensitive and accurate for paratracheal N2 nodes as well. However, there is no significant difference in its detection of N1 lymph nodes.
This article has been cited by other articles:
![]() |
F. J.F. Herth, J. T. Annema, R. Eberhardt, K. Yasufuku, A. Ernst, M. Krasnik, and R. C. Rintoul Endobronchial Ultrasound With Transbronchial Needle Aspiration for Restaging the Mediastinum in Lung Cancer J. Clin. Oncol., July 10, 2008; 26(20): 3346 - 3350. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Cerfolio and A. S. Bryant When is it Best to Repeat a 2-Fluoro-2-Deoxy-D-Glucose Positron Emission Tomography/Computed Tomography Scan on Patients with Non-Small Cell Lung Cancer Who Have Received Neoadjuvant Chemoradiotherapy? Ann. Thorac. Surg., October 1, 2007; 84(4): 1092 - 1097. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. De Leyn, D. Lardinois, P. E. Van Schil, R. Rami-Porta, B. Passlick, M. Zielinski, D. A. Waller, T. Lerut, and W. Weder ESTS guidelines for preoperative lymph node staging for non-small cell lung cancer Eur. J. Cardiothorac. Surg., July 1, 2007; 32(1): 1 - 8. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. De Leyn, S. Stroobants, W. De Wever, T. Lerut, W. Coosemans, G. Decker, P. Nafteux, D. Van Raemdonck, L. Mortelmans, K. Nackaerts, et al. Prospective Comparative Study of Integrated Positron Emission Tomography-Computed Tomography Scan Compared With Remediastinoscopy in the Assessment of Residual Mediastinal Lymph Node Disease After Induction Chemotherapy for Mediastinoscopy-Proven Stage IIIA-N2 Non-Small-Cell Lung Cancer: A Leuven Lung Cancer Group Study J. Clin. Oncol., July 20, 2006; 24(21): 3333 - 3339. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Cerfolio, A. S. Bryant, and B. Ojha Restaging patients with N2 (stage IIIa) non-small cell lung cancer after neoadjuvant chemoradiotherapy: A prospective study J. Thorac. Cardiovasc. Surg., June 1, 2006; 131(6): 1229 - 1235. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Mawlawi, J. J. Erasmus, T. Pan, D. D. Cody, R. Campbell, A. H. Lonn, S. Kohlmyer, H. A. Macapinlac, and D. A. Podoloff Truncation Artifact on PET/CT: Impact on Measurements of Activity Concentration and Assessment of a Correction Algorithm. Am. J. Roentgenol., May 1, 2006; 186(5): 1458 - 1467. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Bunyaviroch and R. E. Coleman PET Evaluation of Lung Cancer J. Nucl. Med., March 1, 2006; 47(3): 451 - 469. [Full Text] [PDF] |
||||
![]() |
C. Pottgen, S. Levegrun, D. Theegarten, S. Marnitz, S. Grehl, R. Pink, W. Eberhardt, G. Stamatis, T. Gauler, G. Antoch, et al. Value of 18F-Fluoro-2-Deoxy-D-Glucose-Positron Emission Tomography/Computed Tomography in Non-Small-Cell Lung Cancer for Prediction of Pathologic Response and Times to Relapse after Neoadjuvant Chemoradiotherapy Clin. Cancer Res., January 1, 2006; 12(1): 97 - 106. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. J. Hoekstra, S. G. Stroobants, E. F. Smit, J. Vansteenkiste, H. van Tinteren, P. E. Postmus, R. P. Golding, B. Biesma, F. J.H.M. Schramel, N. van Zandwijk, et al. Prognostic Relevance of Response Evaluation Using [18F]-2-Fluoro-2-Deoxy-D-Glucose Positron Emission Tomography in Patients With Locally Advanced Non-Small-Cell Lung Cancer J. Clin. Oncol., November 20, 2005; 23(33): 8362 - 8370. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Milleron, V. Westeel, E. Quoix, D. Moro-Sibilot, D. Braun, B. Lebeau, A. Depierre, and for the French Thoracic Cooperative Group Complete Response Following Preoperative Chemotherapy for Resectable Non-Small Cell Lung Cancer: Accuracy of Clinical Assessment Using the French Trial Database Chest, September 1, 2005; 128(3): 1442 - 1447. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. K. Shankar and D. C. Sullivan Functional Imaging in Lung Cancer J. Clin. Oncol., May 10, 2005; 23(14): 3203 - 3211. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Ohtsuka, H. Nomori, K. Watanabe, T. Naruke, H. Orikasa, K. Yamazaki, K. Suemasu, and K. Uno False-positive Findings on [18F]FDG-PET Caused by Non-neoplastic Cellular Elements After Neoadjuvant Chemoradiotherapy for Non-small Cell Lung Cancer Jpn. J. Clin. Oncol., May 1, 2005; 35(5): 271 - 273. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Birim, A. P. Kappetein, T. Stijnen, and A. J.J.C. Bogers Meta-Analysis of Positron Emission Tomographic and Computed Tomographic Imaging in Detecting Mediastinal Lymph Node Metastases in Nonsmall Cell Lung Cancer Ann. Thorac. Surg., January 1, 2005; 79(1): 375 - 382. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Hellwig, T. P. Graeter, D. Ukena, T. Georg, C.-M. Kirsch, and H.-J. Schafers Value of F-18-fluorodeoxyglucose positron emission tomography after induction therapy of locally advanced bronchogenic carcinoma J. Thorac. Cardiovasc. Surg., December 1, 2004; 128(6): 892 - 899. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Cerfolio, A. S. Bryant, T. S. Winokur, B. Ohja, and A. A. Bartolucci Repeat FDG-PET After Neoadjuvant Therapy is a Predictor of Pathologic Response in Patients With Non-Small Cell Lung Cancer Ann. Thorac. Surg., December 1, 2004; 78(6): 1903 - 1909. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. C. Detterbeck, J. F. Vansteenkiste, D. E. Morris, C. A. Dooms, A. H. Khandani, and M. A. Socinski Seeking a Home for a PET, Part 3: Emerging Applications of Positron Emission Tomography Imaging in the Management of Patients With Lung Cancer Chest, November 1, 2004; 126(5): 1656 - 1666. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. De Santis, A. Becherer, C. Bokemeyer, F. Stoiber, K. Oechsle, F. Sellner, A. Lang, K. Kletter, B. M. Dohmen, C. Dittrich, et al. 2-18fluoro-deoxy-D-glucose Positron Emission Tomography Is a Reliable Predictor for Viable Tumor in Postchemotherapy Seminoma: An Update of the Prospective Multicentric SEMPET Trial J. Clin. Oncol., March 15, 2004; 22(6): 1034 - 1039. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Cerfolio, B. Ojha, A. S. Bryant, C. S. Bass, A. A. Bartalucci, and J. M. Mountz The role of FDG-PET scan in staging patients with nonsmall cell carcinoma Ann. Thorac. Surg., September 1, 2003; 76(3): 861 - 866. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |