JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Xavier M. Mueller
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mueller, X. M.
Right arrow Articles by von Segesser, L. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mueller, X. M.
Right arrow Articles by von Segesser, L. K.
Related Collections
Right arrow Valve disease

J Thorac Cardiovasc Surg 2003;125:1405-1411
© 2003 The American Association for Thoracic Surgery


Surgery for Acquired Cardiovascular Disease

A new equine pericardial stentless valve

Xavier M. Mueller, MDa, Ludwig K. von Segesser, MDb

From the Department of Cardio-vascular Surgery, Centre Hospitalier Universitaire de Sherbrooke, Sherbrooke, Quebec, Canada,a and the Department of Cardio-vascular Surgery, Centre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland.b

Received for publication May 30, 2002. Revisions requested Aug 26, 2002; revisions received Sept 9, 2002. Accepted for publication Oct 25, 2002. Address for reprints: Xavier Mueller, MD, Department of Cardio-vascular Surgery, Centre Hospitalier Universitaire de Sherbrooke, 3001, 12e Avenue Nord, Sherbrooke, Quebec, Canada J1H 5N4 (E-mail: xavier.mueller{at}usherbrooke.ca).

Objective: Small aortic valve replacement remains a challenging hemodynamic problem. A new bioprosthesis (3F Therapeutics, Lake Forest, Calif) was designed to further improve the hemodynamic performance currently achieved with stentless bioprostheses. This valve consists of a tubular structure assembled from 3 equal sections of equine pericardial material, with virtually no foreign material except for a thin polyester ring. Its hemodynamic performance was compared with that of a commercially available stentless prosthesis in a bovine model.
Patients and Methods: Twelve calves (55 ± 2.8 kg) received a 19-mm 3F valve (3F group, n = 6) or a 19-mm stentless control valve (control group, n = 6). The animals were fully equipped for hemodynamic monitoring and transvalvular gradient measurements. After implantation, dopamine was infused in increasing doses, and the hemodynamic values were recorded at each step of 100-µg/min increase. Linear regression analysis was applied for group comparison of each variable.
Results: The mean transvalvular gradient at 4.5 L/min was 3.48 ± 0.14 mm Hg (95% confidence interval) in the 3F group and 5.72 ± 0.28 mm Hg in the control group (P < .0001) and at 6.5 L/min, 7.4 ± 1.55 mm Hg, and 11.13 ± 0.18 mm Hg, respectively (P < .0001). The effective orifice area at 4.5 L/min was 2.4 ± 0.03 cm2 in the 3F group and 1.86 ± 0.02 cm2 in the control group (P < .0001) and at 6.5 L/min, 2.41 ± 0.04 cm2, and 1.96 ± 0.02 cm2, respectively (P < .0001).
Conclusions: This new bioprosthesis without a stent and without a supporting wall that has its commissures fixed directly to the aorta outperforms in vivo standard stentless prostheses in the immediate postimplant period.




This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
D. Wendt, M. Thielmann, T. Buck, R.-A. Janosi, T. Bossert, N. Pizanis, M. Kamler, and H. Jakob
First clinical experience and 1-year follow-up with the sutureless 3F-Enable aortic valve prosthesis
Eur. J. Cardiothorac. Surg., April 1, 2008; 33(4): 542 - 547.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
W. A. Goetz, T. E. Tan, K. H. Lim, S. L. H. Salgues, N. Grousson, F. Xiong, Y. L. Chua, and J. H. Yeo
Truly stentless molded autologous pericardial aortic valve prosthesis with single point attached commissures in a sheep model
Eur. J. Cardiothorac. Surg., April 1, 2008; 33(4): 548 - 553.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
W. A. Goetz, K. H. Lim, R. Ibled, N. Grousson, S. L. H. Salgues, and J. H. Yeo
Forces at single point attached commissures (SPAC) in pericardial aortic valve prosthesis
Eur. J. Cardiothorac. Surg., February 1, 2006; 29(2): 150 - 155.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. L. Cox, N. Ad, K. Myers, M. Gharib, and R.C. Quijano
Tubular heart valves: A new tissue prosthesis design--Preclinical evaluation of the 3F aortic bioprosthesis
J. Thorac. Cardiovasc. Surg., August 1, 2005; 130(2): 520 - 527.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2003 by The American Association for Thoracic Surgery.