J Thorac Cardiovasc Surg 2003;126:66-74
© 2003 The American Association for Thoracic Surgery
Surgery for acquired cardiovascular disease |
a Department of Cardiovascular SurgeryUniversity of Padua, Medical School of Padua, Padua, Italy
b Department of Cardiovascular Pathology, University of Padua Medical School, Padua, Italy
Received for publication June 5, 2002 Received for publication August 30, 2002; revisions received October 16, 2002; accepted for publication October 21, 2002.
* Address for reprints: Giulio Rizzoli, MD, Institute of Cardiovascular Surgery, University of Padua, Via Giustiniani, 2, Padua 35100, Italy
giulio.rizzoli{at}unipd.it
BACKGROUND: Survival and prosthetic complications of patients receiving the Hancock II second-generation bioprosthesis (Medtronic, Inc, Minneapolis, Minn) in the aortic, mitral, mitral-aortic, and tricuspid positions were analyzed at 15 years follow-up.
METHODS: Between May 1983 and December 1993, 212 patients (104 men and 108 women; mean age, 63 ± 9 years; age range, 29-81 years) received 66 aortic, 114 mitral, 26 mitral-aortic, and 6 tricuspid Hancock II valves. Thirty-one percent of patients had previous valve operations, 15% had concomitant cardiac procedures, and 87% were in New York Heart Association class III or IV. Follow-up included 1704 patient-years and was 98% complete, with a median of 9 patient-years (range, 0.013-17.4 years). Forty-six patients were at risk at 14 to 15 years, and 30 were at risk after 15 years.
RESULTS: One hundred twenty-two (57%) of 212 patients died, 20 of them perioperatively. Fifteen-year actuarial Kaplan-Meier survival was 35.2% ± 3.8%, and freedom from valve-related mortality was 84% ± 3.5%, with no difference on the basis of position or age (<65 or
65 years). Percentages for freedom from thromboembolism, anticoagulant-related hemorrhage, endocarditis, and paravalvular leak were, respectively, 78.2% ± 4%, 83.5% ± 3.6%, 95.7% ± 2%, and 97.3% ± 1.4%, with no significant difference between the aortic and mitral positions. Freedom from structural valve deterioration was 71.8% ± 5.6%: 88.9% ± 6.2% in the aortic position versus 59.5% ± 3.9% in the mitral position (P = .01) and 64.3% ± 3% in the mitral-aortic position. In patients younger than 65 years, actual freedom from structural valve deterioration was less than that seen in older patients (84.5% ± 3.5% vs 95% ± 3.0%) and was better in the aortic versus the mitral position (92% ± 4.5% vs 82% ± 4.2%).
CONCLUSION: The Hancock II porcine valve showed excellent 15-year durability. We recommend its use in patients 65 years of age, as well as in younger patients undergoing aortic replacement.
This article has been cited by other articles:
![]() |
E. Pettenazzo, M. Valente, and G. Thiene Octanediol treatment of glutaraldehyde fixed bovine pericardium: evidence of anticalcification efficacy in the subcutaneous rat model Eur. J. Cardiothorac. Surg., August 1, 2008; 34(2): 418 - 422. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Gudbjartsson, T. Absi, and S. Aranki Mitral Valve Replacement Card. Surg. Adult, January 1, 2008; 3(2008): 1031 - 1068. [Full Text] |
||||
![]() |
T. Bottio, M. Valente, G. Rizzoli, V. Tarzia, G. Bisleri, E. Pettenazzo, G. Gerosa, and G. Thiene Commissural dehiscence: a rare and peculiar cause of porcine valve structural deterioration. J. Thorac. Cardiovasc. Surg., November 1, 2006; 132(5): 1017 - 1022. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kulik, P. Bedard, B-K. Lam, F. D. Rubens, P. J. Hendry, R. G. Masters, T. G. Mesana, and M. Ruel Mechanical versus bioprosthetic valve replacement in middle-aged patients. Eur. J. Cardiothorac. Surg., September 1, 2006; 30(3): 485 - 491. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. E. Jamieson, E. Germann, M. R Aupart, P. H Neville, M. A Marchand, and G. J Fradet 15-Year Comparison of Supra-Annular Porcine and PERIMOUNT Aortic Bioprostheses Asian Cardiovasc Thorac Ann, June 1, 2006; 14(3): 200 - 205. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M. Davierwala, M. A. Borger, T. E. David, V. Rao, M. Maganti, and T. M. Yau Reoperation is not an independent predictor of mortality during aortic valve surgery J. Thorac. Cardiovasc. Surg., February 1, 2006; 131(2): 329 - 335. [Abstract] [Full Text] [PDF] |
||||
![]() |
W.R. E. Jamieson, L. H. Burr, R. T. Miyagishima, E. Germann, J. S. MacNab, E. Stanford, F. Chan, M. T. Janusz, and H. Ling Carpentier-Edwards supra-annular aortic porcine bioprosthesis: Clinical performance over 20 years J. Thorac. Cardiovasc. Surg., October 1, 2005; 130(4): 994 - 1000. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. S. Bach, N. D. Kon, J. G. Dumesnil, C. F. Sintek, and D. B. Doty Ten-Year Outcome After Aortic Valve Replacement with the Freestyle Stentless Bioprosthesis Ann. Thorac. Surg., August 1, 2005; 80(2): 480 - 487. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Polvani, F. Barili, L. Dainese, M. Muratori, M. Porqueddu, A. Sala, and P. Biglioli Long-Term Results After Aortic Valve Replacement With the Bravo 400 Stentless Xenograft Ann. Thorac. Surg., August 1, 2005; 80(2): 495 - 501. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Rizzoli, T. Bottio, V. Vida, G. Nesseris, L. Caprili, G. Thiene, and G. Gerosa Intermediate results of isolated mitral valve replacement with a Biocor porcine valve J. Thorac. Cardiovasc. Surg., February 1, 2005; 129(2): 322 - 329. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. D. Desai, O. Merin, G. N. Cohen, J. Herman, S. Mobilos, J. Y. Sever, S. E. Fremes, B. S. Goldman, and G. T. Christakis Long-Term Results of Aortic Valve Replacement With the St. Jude Toronto Stentless Porcine Valve Ann. Thorac. Surg., December 1, 2004; 78(6): 2076 - 2083. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. DiGregorio, K. J. Zehr, T. A. Orszulak, C. J. Mullany, R. C. Daly, J. A. Dearani, and H. V. Schaff Results of mitral surgery in octogenarians with isolated nonrheumatic mitral regurgitation Ann. Thorac. Surg., September 1, 2004; 78(3): 807 - 813. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. G. Masters, M. Haddad, A. L. Pipe, J. P. Veinot, and T. Mesana Clinical outcomes with the Hancock II bioprosthetic valve Ann. Thorac. Surg., September 1, 2004; 78(3): 832 - 836. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Bottio, G. Rizzoli, G. Thiene, G. Nesseris, D. Casarotto, and G. Gerosa Hemodynamic and clinical outcomes with the Biocor valve in the aortic position: An 8-year experience J. Thorac. Cardiovasc. Surg., June 1, 2004; 127(6): 1616 - 1623. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |