|
|
||||||||
J Thorac Cardiovasc Surg 2003;126:783-793
© 2003 The American Association for Thoracic Surgery
Surgery for acquired cardiovascular disease |
a Department of Thoracic and Cardiovascular Surgery, The Cleveland Clinic Foundation, Cleveland, Ohio, USA,
b Department of Biostatistics and Epidemiology, The Cleveland Clinic Foundation, Cleveland, OhioUSA
c The University of British Columbia, Vancouver, British Columbia, Canada
d Dartmouth Medical School, Dartmouth-Hitchcock Medical Center, Lebanon, NHUSA
e Northwest Surgical Associates, Portland, OreUSA
f Stanford University, Stanford, CalifUSA
g University Hospital, Cardiff, United Kingdom
h Instituto Chirurgia Cardiovascolare, University of Padova, Padova, Italy
i Harefield Hospital, London, United Kingdom
j Edwards Lifesciences Corporation, Irvine, CalifUSA
Read at the Eightieth Annual Meeting of The American Association for Thoracic Surgery, Toronto, Ontario, Canada, April 30May 3, 2000.
Received for publication April 28, 2000; revisions received November 27, 2002; accepted for publication February 26, 2003.
* Address for reprints: Eugene H. Blackstone, MD, The Cleveland Clinic Foundation, 9500 Euclid Ave, Desk F25, Cleveland, OH 44195, USA
blackse{at}ccf.org
OBJECTIVE: This study was undertaken to quantify the relationship between prosthesis size adjusted for patient size (prosthesis-patient size) and long-term survival after aortic valve replacement.
METHODS: Data from nine representative sources on 13,258 aortic valve replacements provided 69,780 patient-years of follow-up (mean 5.3 ± 4.7 years), with reliable survival estimates to 15 years. Prostheses included 5757 stented porcine xenografts, 3198 stented bovine pericardial xenografts, 3583 mechanical valves, and 720 allografts. Manufacturers labeled prosthesis size was 19 mm or smaller in 1109 patients. Expressions of prosthesis-patient size assessed were indexed internal prosthesis orifice area (in centimeters squared per square meter of body surface area) and standardized internal prosthesis orifice size (Z, the number of SDs from mean normal native aortic valve size). Multivariable hazard domain analysis with balancing score and risk factor adjustment quantified the association of prosthesis-patient size with survival.
RESULTS: Prosthesis-patient size down to at least 1.1 cm2/m2 or -3 Z did not adversely affect intermediate- or long-term survival (P > .2). However, 30-day mortality increased 1% to 2% when indexed orifice area fell below 1.2 cm2/m2 (P = .002) or standardized orifice size fell below -2.5 Z (P = .0003). The increased early risk affected fewer than 1% of patients receiving bioprostheses but about 25% of those receiving mechanical devices.
CONCLUSIONS: Aortic prosthesis-patient size down to 1.1 cm2/m2 or -3 Z did not reduce intermediate- or long-term survival after aortic valve replacement. However, patient-prosthesis size under 1.2 cm2/m2 or -2.5 Z was associated with a 1% to 2% increase in 30-day mortality. Prosthesis-patient sizes this small or smaller were rarely implanted in patients receiving bioprostheses.
This article has been cited by other articles:
![]() |
V. A. Mannacio, V. De Amicis, L. Di Tommaso, F. Iorio, and C. Vosa Influence of prosthesis-patient mismatch on exercise-induced arrhythmias: a further aspect after aortic valve replacement. J. Thorac. Cardiovasc. Surg., September 1, 2009; 138(3): 632 - 638. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Urso, R. Sadaba, and G. Aldamiz-Echevarria Is patient-prosthesis mismatch an independent risk factor for early and mid-term overall mortality in adult patients undergoing aortic valve replacement? Interactive CardioVascular and Thoracic Surgery, September 1, 2009; 9(3): 510 - 518. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-L. Monin Prosthesis-patient mismatch: myth or reality? Heart, June 1, 2009; 95(11): 948 - 952. [Full Text] [PDF] |
||||
![]() |
M. R. Moon, J. S. Lawton, N. Moazami, N. A. Munfakh, M. K. Pasque, and R. J. Damiano Jr. POINT: Prosthesis-patient mismatch does not affect survival for patients greater than 70 years of age undergoing bioprosthetic aortic valve replacement. J. Thorac. Cardiovasc. Surg., February 1, 2009; 137(2): 278 - 283. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Mohty, J. G. Dumesnil, N. Echahidi, P. Mathieu, F. Dagenais, P. Voisine, and P. Pibarot Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: influence of age, obesity, and left ventricular dysfunction. J. Am. Coll. Cardiol., January 6, 2009; 53(1): 39 - 47. [Abstract] [Full Text] [PDF] |
||||
![]() |
J Mascherbauer, R Rosenhek, C Fuchs, E Pernicka, U Klaar, C Scholten, M Heger, G Wollenek, G Maurer, and H Baumgartner Moderate patient-prosthesis mismatch after valve replacement for severe aortic stenosis has no impact on short-term and long-term mortality Heart, December 1, 2008; 94(12): 1639 - 1645. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. R. Nowicki, G. B. Pettersson, N. G. Smedira, E. E. Roselli, E. H. Blackstone, and B. W. Lytle Aortic Allograft Valve Reoperation: Surgical Challenges and Patient Risks Ann. Thorac. Surg., September 1, 2008; 86(3): 761 - 768. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. G. Svensson, T. Dewey, S. Kapadia, E. E. Roselli, A. Stewart, M. Williams, W. N. Anderson, D. Brown, M. Leon, B. Lytle, et al. United States Feasibility Study of Transcatheter Insertion of a Stented Aortic Valve by the Left Ventricular Apex Ann. Thorac. Surg., July 1, 2008; 86(1): 46 - 55. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. C. Waisbren, L.-M. Stevens, E. G. Avery, M. H. Picard, G. J. Vlahakes, and A. K. Agnihotri Changes in Mitral Regurgitation After Replacement of the Stenotic Aortic Valve Ann. Thorac. Surg., July 1, 2008; 86(1): 56 - 62. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Walther, V. Falk, J. Kempfert, M. A. Borger, J. Fassl, M. W.A. Chu, G. Schuler, and F. W. Mohr Transapical minimally invasive aortic valve implantation; the initial 50 patients Eur. J. Cardiothorac. Surg., June 1, 2008; 33(6): 983 - 988. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. I. Duncan, B. S. Lowe, M. J. Garcia, M. Xu, A. M. Gillinov, T. Mihaljevic, and C. G. Koch Influence of Concentric Left Ventricular Remodeling on Early Mortality After Aortic Valve Replacement Ann. Thorac. Surg., June 1, 2008; 85(6): 2030 - 2039. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Mihaljevic, E. R. Nowicki, J. Rajeswaran, E. H. Blackstone, L. Lagazzi, J. Thomas, B. W. Lytle, and D. M. Cosgrove Survival after valve replacement for aortic stenosis: Implications for decision making. J. Thorac. Cardiovasc. Surg., June 1, 2008; 135(6): 1270 - 1279.e12. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Kohsaka, S. Mohan, S. Virani, V.-V. Lee, A. Contreras, G. J. Reul, and S. A. Coulter Prosthesis-patient mismatch affects long-term survival after mechanical valve replacement. J. Thorac. Cardiovasc. Surg., May 1, 2008; 135(5): 1076 - 1080. [Abstract] [Full Text] [PDF] |
||||
![]() |
S Bleiziffer, W B Eichinger, I Hettich, D Ruzicka, M Wottke, R Bauernschmitt, and R Lange Impact of patient-prosthesis mismatch on exercise capacity in patients after bioprosthetic aortic valve replacement Heart, May 1, 2008; 94(5): 637 - 641. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Yoshikawa, S. Fukunaga, K. Arinaga, H. Hori, E. Nakamura, T. Ueda, E. Tayama, and S. Aoyagi Long-Term Results of Aortic Valve Replacement With a Small St. Jude Medical Valve in Japanese Patients Ann. Thorac. Surg., April 1, 2008; 85(4): 1303 - 1308. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Emery, A. M. Emery, A. Knutsen, and G. V. Raikar Aortic Valve Replacement with a Mechanical Cardiac Valve Prosthesis Card. Surg. Adult, January 1, 2008; 3(2008): 841 - 856. [Full Text] |
||||
![]() |
N. D. Desai and G. T. Christakis Bioprosthetic Aortic Valve Replacement: Stented Pericardial and Porcine Valves Card. Surg. Adult, January 1, 2008; 3(2008): 857 - 894. [Full Text] |
||||
![]() |
J.-L. Monin, M. Monchi, M. E.W. Kirsch, H. Petit-Eisenmann, S. Baleynaud, C. Chauvel, D. Metz, C. Adams, J.-P. Quere, P. Gueret, et al. Low-gradient aortic stenosis: impact of prosthesis-patient mismatch on survival Eur. Heart J., November 1, 2007; 28(21): 2620 - 2626. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Dhareshwar, T. M. Sundt III, J. A. Dearani, H. V. Schaff, D. J. Cook, and T. A. Orszulak Aortic root enlargement: What are the operative risks? J. Thorac. Cardiovasc. Surg., October 1, 2007; 134(4): 916 - 924. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Walther, P. Simon, T. Dewey, G. Wimmer-Greinecker, V. Falk, M. T. Kasimir, M. Doss, M. A. Borger, G. Schuler, D. Glogar, et al. Transapical Minimally Invasive Aortic Valve Implantation: Multicenter Experience Circulation, September 11, 2007; 116(11_suppl): I-240 - I-245. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. B. Vanky, E. Hakanson, and R. Svedjeholm Long-Term Consequences of Postoperative Heart Failure After Surgery for Aortic Stenosis Compared With Coronary Surgery Ann. Thorac. Surg., June 1, 2007; 83(6): 2036 - 2043. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. D. Peterson, M. A. Borger, C. M. Feindel, and T. E. David Aortic Annular Enlargement During Aortic Valve Replacement: Improving Results With Time Ann. Thorac. Surg., June 1, 2007; 83(6): 2044 - 2049. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Pibarot and J. G. Dumesnil Prosthesis-patient mismatch in the mitral position: Old concept, new evidences J. Thorac. Cardiovasc. Surg., June 1, 2007; 133(6): 1405 - 1408. [Full Text] [PDF] |
||||
![]() |
I. M. Wagner, W. B. Eichinger, S. Bleiziffer, F. Botzenhardt, I. Gebauer, R. Guenzinger, R. Bauernschmitt, and R. Lange Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus J. Thorac. Cardiovasc. Surg., May 1, 2007; 133(5): 1234 - 1241. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Pibarot and J. G Dumesnil Prevention of valve prosthesis--patient mismatch before aortic valve replacement: does it matter and is it feasible? Heart, May 1, 2007; 93(5): 549 - 551. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Bleiziffer, W. B Eichinger, I. Hettich, R. Guenzinger, D. Ruzicka, R. Bauernschmitt, and R. Lange Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method? Heart, May 1, 2007; 93(5): 615 - 620. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. R. Bridges, S. M. O'Brien, J. C. Cleveland, E. B. Savage, J. S. Gammie, F. H. Edwards, E. D. Peterson, and F. L. Grover Association between indices of prosthesis internal orifice size and operative mortality after isolated aortic valve replacement J. Thorac. Cardiovasc. Surg., April 1, 2007; 133(4): 1012 - 1021. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. Bolman III Survival After Mitral Valve Replacement: Does the Valve Type and/or Size Make a Difference? Circulation, March 20, 2007; 115(11): 1336 - 1338. [Full Text] [PDF] |
||||
![]() |
J. Magne, P. Mathieu, J. G. Dumesnil, D. Tanne, F. Dagenais, D. Doyle, and P. Pibarot Impact of Prosthesis-Patient Mismatch on Survival After Mitral Valve Replacement Circulation, March 20, 2007; 115(11): 1417 - 1425. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Bakhtiary, M. Schiemann, O. Dzemali, S. Dogan, V. Schachinger, H. Ackermann, A. Moritz, and P. Kleine Impact of Patient-Prosthesis Mismatch and Aortic Valve Design on Coronary Flow Reserve After Aortic Valve Replacement J. Am. Coll. Cardiol., February 20, 2007; 49(7): 790 - 796. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Bleiziffer, W. B. Eichinger, and R. Lange Letter by Bleiziffer et al Regarding Article, "Long-Term Outcomes After Valve Replacement for Low-Gradient Aortic Stenosis: Impact of Prosthesis-Patient Mismatch" Circulation, December 5, 2006; 114(23): e627 - e627. [Full Text] [PDF] |
||||
![]() |
T. Bove, Y. Van Belleghem, K. Francois, F. Caes, H. Van Overbeke, and G. Van Nooten Stentless and stented aortic valve replacement in elderly patients: factors affecting midterm clinical and hemodynamical outcome Eur. J. Cardiothorac. Surg., November 1, 2006; 30(5): 706 - 713. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Kunihara, K. Schmidt, P. Glombitza, V. Dzindzibadze, H. Lausberg, and H.-J. Schafers Root replacement using stentless valves in the small aortic root: a propensity score analysis. Ann. Thorac. Surg., October 1, 2006; 82(4): 1379 - 1384. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. I. Duncan, J. Lin, C. G. Koch, A. M. Gillinov, M. Xu, and N. J. Starr The Impact of Gender on In-Hospital Mortality and Morbidity After Isolated Aortic Valve Replacement Anesth. Analg., October 1, 2006; 103(4): 800 - 808. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Rizzoli, S. Mirone, P. Ius, E. Polesel, T. Bottio, L. Salvador, C. Zussa, G. Gerosa, and C. Valfre Fifteen-year results with the Hancock II valve: A multicenter experience. J. Thorac. Cardiovasc. Surg., September 1, 2006; 132(3): 602 - 609.e4. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Flameng, B. Meuris, P. Herijgers, and M.-C. Herregods Prosthesis-Patient Mismatch is Not Clinically Relevant in Aortic Valve Replacement Using the Carpentier-Edwards Perimount Valve Ann. Thorac. Surg., August 1, 2006; 82(2): 530 - 536. [Abstract] [Full Text] [PDF] |
||||
![]() |
P Pibarot and J G Dumesnil Prosthesis-patient mismatch: definition, clinical impact, and prevention Heart, August 1, 2006; 92(8): 1022 - 1029. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. J. Howell, B. E. Keogh, V. Barnet, R. S. Bonser, T. R. Graham, S. J. Rooney, I. C. Wilson, and D. Pagano Patient-prosthesis mismatch does not affect survival following aortic valve replacement. Eur. J. Cardiothorac. Surg., July 1, 2006; 30(1): 10 - 14. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Walther, A. Rastan, V. Falk, S. Lehmann, J. Garbade, A. K. Funkat, F. W. Mohr, and J. F. Gummert Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement. Eur. J. Cardiothorac. Surg., July 1, 2006; 30(1): 15 - 19. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Lund and M. Bland Risk-corrected impact of mechanical versus bioprosthetic valves on long-term mortality after aortic valve replacement J. Thorac. Cardiovasc. Surg., July 1, 2006; 132(1): 20 - 26. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. G. Dumesnil and P. Pibarot Prosthesis-patient mismatch and clinical outcomes: The evidence continues to accumulate J. Thorac. Cardiovasc. Surg., May 1, 2006; 131(5): 952 - 955. [Full Text] [PDF] |
||||
![]() |
F. B. Vanky, E. Hakanson, E. Tamas, and R. Svedjeholm Risk Factors for Postoperative Heart Failure in Patients Operated on for Aortic Stenosis Ann. Thorac. Surg., April 1, 2006; 81(4): 1297 - 1304. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. P. Taggart Prosthesis patient mismatch in aortic valve replacement: possible but pertinent? Eur. Heart J., March 2, 2006; 27(6): 644 - 646. [Full Text] [PDF] |
||||
![]() |
M. R. Moon, M. K. Pasque, N. A. Munfakh, S. J. Melby, J. S. Lawton, N. Moazami, J. E. Codd, T. D. Crabtree, H. B. Barner, and R. J. Damiano Jr Prosthesis-Patient Mismatch After Aortic Valve Replacement: Impact of Age and Body Size on Late Survival Ann. Thorac. Surg., February 1, 2006; 81(2): 481 - 489. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Bernal, J. Lorca, D. Prieto-Salceda, I. Pulitani, A. Ponton, I. Garcia, and J. M. Revuelta Performance at 10 years of the CarboMedics 'Top-Hat' valve. Postclamping time is a predictor of mortality Eur. J. Cardiothorac. Surg., February 1, 2006; 29(2): 144 - 149. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Tasca, Z. Mhagna, S. Perotti, P. B. Centurini, T. Sabatini, A. Amaducci, F. Brunelli, M. Cirillo, M. D. Tomba, E. Quiani, et al. Impact of Prosthesis-Patient Mismatch on Cardiac Events and Midterm Mortality After Aortic Valve Replacement in Patients With Pure Aortic Stenosis Circulation, January 31, 2006; 113(4): 570 - 576. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Mohty-Echahidi, J. F. Malouf, S. E. Girard, H. V. Schaff, D. E. Grill, M. E. Enriquez-Sarano, and F. A. Miller Jr Impact of Prosthesis-Patient Mismatch on Long-Term Survival in Patients With Small St Jude Medical Mechanical Prostheses in the Aortic Position Circulation, January 24, 2006; 113(3): 420 - 426. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Pibarot, J. G. Dumesnil, G. Tasca, C. G. Koch, F. Khandwala, F. G. Estafanous, F. D. Loop, and E. H. Blackstone Letter Regarding Article by Koch et al, "Impact of Prothesis-Patient Size on Functional Recovery After Aortic Valve Replacement" * Response Circulation, November 22, 2005; 112(21): e333 - e333. [Full Text] [PDF] |
||||
![]() |
T. E. David Is Prosthesis-Patient Mismatch a Clinically Relevant Entity? Circulation, June 21, 2005; 111(24): 3186 - 3187. [Full Text] [PDF] |
||||
![]() |
C. G. Koch, F. Khandwala, F. G. Estafanous, F. D. Loop, and E. H. Blackstone Impact of Prosthesis-Patient Size on Functional Recovery After Aortic Valve Replacement Circulation, June 21, 2005; 111(24): 3221 - 3229. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Penta de Peppo, J. Zeitani, P. Nardi, G. Iaci, P. Polisca, R. De Paulis, and L. Chiariello Small "Functional" Size after Mechanical Aortic Valve Replacement: No Risk in Young to Middle-Age Patients Ann. Thorac. Surg., June 1, 2005; 79(6): 1915 - 1920. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. H. Cohn Use of Heart Valves in Older Patients Circulation, May 3, 2005; 111(17): 2152 - 2153. [Full Text] [PDF] |
||||
![]() |
H.-H. Sievers Prosthetic aortic valve replacement J. Thorac. Cardiovasc. Surg., May 1, 2005; 129(5): 961 - 965. [Full Text] [PDF] |
||||
![]() |
F. A. Crawford Jr Residual pulmonary artery hypertension after mitral valve replacement: Size matters! J. Am. Coll. Cardiol., April 5, 2005; 45(7): 1041 - 1042. [Full Text] [PDF] |
||||
![]() |
R. G. Fuster, J. A. M. Argudo, O. G. Albarova, F. H. Sos, S. C. Lopez, M. B. Codoner, J. A. B. Minano, and I. R. Albarran Patient-prosthesis mismatch in aortic valve replacement: really tolerable? Eur. J. Cardiothorac. Surg., March 1, 2005; 27(3): 441 - 449. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Amarelli, A. Della Corte, G. Romano, G. Iasevoli, G. Dialetto, L. S. De Santo, M. De Feo, M. Torella, M. Scardone, and M. Cotrufo Left ventricular mass regression after aortic valve replacement with 17-mm St Jude Medical mechanical prostheses in isolated aortic stenosis J. Thorac. Cardiovasc. Surg., March 1, 2005; 129(3): 512 - 517. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Gaudino, F. Alessandrini, F. Glieca, N. Luciani, C. Cellini, C. Pragliola, M. Morelli, C. Canosa, G. Nasso, and G. Possati Survival after aortic valve replacement for aortic stenosis: does left ventricular mass regression have a clinical correlate? Eur. Heart J., January 1, 2005; 26(1): 51 - 57. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. G. Dumesnil and P. Pibarot Prosthesis size and prosthesis-patient size are unrelated to prosthesis-patient mismatch J. Thorac. Cardiovasc. Surg., June 1, 2004; 127(6): 1852 - 1852. [Full Text] [PDF] |
||||
![]() |
E. H. Blackstone, A. M. Gillinov, and D. M. Cosgrove Reply to the Editor J. Thorac. Cardiovasc. Surg., June 1, 2004; 127(6): 1852 - 1854. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |