J Thorac Cardiovasc Surg 2003;126:1568-1574
© 2003 The American Association for Thoracic Surgery
Evolving technology |
a Division of Thoracic and Cardiovascular Surgery, Medical School, Hannover, Germany
b Department of Cardiac Surgery, Heart Center University, Leipzig, Germany
c Department of Thoracic and Cardiovascular Surgery, JW-Goethe University, Frankfurt, Germany
Received for publication May 22, 2002; revisions received August 15, 2002; revisions received March 12, 2003; accepted for publication April 10, 2003.
* Address for reprints: Uwe Klima, MD, PhD, Department of Thoracic and Cardiovascular Surgery, Hannover Medical School, 30623 Hannover, Germany
klima{at}thg-mh.hannover.de
OBJECTIVE: The hand-sewn anastomosis is the "gold standard" for performing coronary artery bypass grafts. However, performing a hand-sewn anastomosis is more demanding and time-consuming when used in less invasive approaches such as small access, totally endoscopic or beating heart surgery. In conjunction with attempts to reduce the surgical trauma of coronary artery bypass grafts by using these less invasive approaches, alternative methods for constructing distal anastomoses should be explored. These data report on predischarge angiographic findings and 30-day clinical follow up of patients who have received a new distal anastomotic device.
METHODS: In a multicenter trial, 32 patients (mean age: 65 ± 9 years; 85% men) requiring multivessel coronary artery bypass surgery had 1 of the anastomoses performed using a novel anastomotic technology. The Magnetic Vascular Positioner System was used in 1 of the bypass grafts and the other bypasses were completed by conventional hand-sewn technique. The Magnetic Vascular Positioner System consists of 4 magnetic, gold-plated implants and 2 delivery devices that facilitate the creation of a functional end-to-side anastomosis. A predischarge angiogram was performed to evaluate graft patency.
RESULTS: There were no device-related major adverse events. The application of the Magnetic Vascular Positioner device was successful in 32 of 41 cases (78%). Nine patients were intended for treatment but did not receive the Magnetic Vascular Positioner System. In 5 of the cases the coronary artery was too small; 1 case had a posterior wall plaque in the target artery; and 3 patients had a nonhemostatic anastomosis after coupling of the port and were subsequently converted to hand-sewn anastomoses. The median total Magnetic Vascular Positioner anastomotic time was 137 seconds with a range from 65 to 370 seconds. Overall patency rate of the Magnetic Vascular Positioner anastomosis was 93.5% versus 91.7% (P = not significant) in hand-sewn grafts. One patient (3.1%) died due to low cardiac output but had patent grafts at autopsy. One myocardial infarction (3.1%) occurred the day after a percutaneous transluminal coronary angioplasty of a hand-sewn graft. One prolonged mechanical ventilation (3.1%) was required because of pneumonia and adult respiratory distress syndrome.
CONCLUSIONS: Magnetic vascular coupling in coronary surgery is safe and effective and has acceptable early patency rates. This new technique may facilitate beating heart and minimally invasive coronary artery bypass grafts.
This article has been cited by other articles:
![]() |
W. J.L. Suyker and C. Borst Coronary connector devices: analysis of 1,469 anastomoses in 1,216 patients. Ann. Thorac. Surg., May 1, 2008; 85(5): 1828 - 1836. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Klima, J. Beilner, E. Bagaev, S. Fischer, T. Kofidis, and J. Lotz MRI-Based Safety Evaluation of the Ventrica Magnetic Coronary Anastomotic System Asian Cardiovasc Thorac Ann, February 1, 2007; 15(1): 24 - 29. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Vicol, S. Eifert, M. Oberhoffer, P. Boekstegers, and B. Reichart Mid-term patency after magnetic coupling for distal bypass anastomosis in coronary surgery. Ann. Thorac. Surg., October 1, 2006; 82(4): 1452 - 1456. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. J.L. Suyker, J. P. Matonick, P. T.W. Suyker, A. Brutel de la Riviere, M. P. Buijsrogge, R. P.J. Budde, C. W.J. Verlaan, G. Pasterkamp, P. F. Grundeman, and C. Borst S2 Connector Versus Suture: Distal Coronary Anastomosis Remodeling, Patency, and Function in the Pig Circulation, July 4, 2006; 114(1_suppl): I-390 - I-395. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Klima, T. Kofidis, J. Beilner, M. Maringka, S. Kirschner, and A. Haverich Anastomotic Obstruction After Magnetic Vascular Coupling After Minimally Invasive Direct Coronary Artery Bypass Grafting Ann. Thorac. Surg., February 1, 2006; 81(2): 728 - 729. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. P.J. Budde, W. J.L. Suyker, P. T.W. Suyker, C. W.J. Verlaan, R. Meijer, C. Borst, and P. F. Grundeman Quality assessment of distal S2AS connector anastomosis by 13MHz epicardial ultrasound Eur. J. Cardiothorac. Surg., December 1, 2005; 28(6): 833 - 837. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Klima, T. Kofidis, A. Boening, and A. Haverich Long term angiographic monitoring reveals safety and efficacy of the Converge end-to-side anastomotic coupler Interactive CardioVascular and Thoracic Surgery, December 1, 2005; 4(6): 505 - 508. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Boening, F. Schoeneich, A. Lichtenberg, E. Bagaev, J. T. Cremer, and U. Klima First clinical results with a 30{degrees} end-to-side coronary anastomosis coupler Eur. J. Cardiothorac. Surg., May 1, 2005; 27(5): 876 - 881. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Vicol, S. Eifert, M. Oberhoffer, P. Boekstegers, A. Knez, F. Christ, and B. Reichart Early Clinical Results With a Magnetic Connector for Distal Coronary Artery Anastomoses Ann. Thorac. Surg., May 1, 2005; 79(5): 1738 - 1742. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. P. Kypson and W. R. Chitwood Jr INVITED COMMENTARY Ann. Thorac. Surg., May 1, 2005; 79(5): 1742 - 1743. [Full Text] [PDF] |
||||
![]() |
U. Klima, H. MacVaugh III, E. Bagaev, M. Maringka, S. Kirschner, J. Beilner, and A. Haverich Magnetic Vascular Port in Minimally Invasive Direct Coronary Artery Bypass Grafting Circulation, September 14, 2004; 110(11_suppl_1): II-55 - II-60. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Carrel, L. Englberger, D. Keller, S. Windecker, B. Meier, and F. Eckstein Clinical and angiographic results after mechanical connection for distal anastomosis in coronary surgery J. Thorac. Cardiovasc. Surg., June 1, 2004; 127(6): 1632 - 1640. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |