JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Filsoufi, F.
Right arrow Articles by Adams, D. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Filsoufi, F.
Right arrow Articles by Adams, D. H.
Related Collections
Right arrow Minimally invasive surgery

J Thorac Cardiovasc Surg 2004;127:185-192
© 2004 The American Association for Thoracic Surgery


Evolving technology

Automated distal coronary bypass with a novel magnetic coupler (MVP system)

F. Filsoufi, MDa, R. S. Farivar, MDa, L. Aklog, MDa, C. A. Anderson, MDa, R. H. Chen, MDa, S. Lichtenstein, MDb, J. Zhang, MDb, D. H. Adams, MDa,*

a Brigham and Women's Hospital and Harvard Medical School, Boston, Mass, USA
b Cardiovascular and Thoracic Surgery, University of British Columbia, Vancouver, British Columbia, Canada

Read at the Eighty-second Annual Meeting of The American Association for Thoracic Surgery, Washington, DC, May 5-8, 2002.

Received for publication July 10, 2002; revisions received November 12, 2002; accepted for publication April 16, 2003.

* Address for reprints: David H. Adams, MD, Department of Cardiothoracic Surgery, Mount Sinai Medical Center, 1190 Fifth Ave, New York, NY 10029, USA
david.adams{at}mountsinai.org

OBJECTIVE: We sought to assess the feasibility of performing sutureless distal coronary artery bypass anastomoses with a novel magnetic coupling device.

METHODS: From May 2000 to April 2001, single-vessel side-to-side coronary artery bypass grafting on a beating heart was performed in 39 domestic white pigs (35-60 kg) without the use of mechanical stabilization, shunts, or perfusion bridges. Animals were divided into 2 groups. Seventeen pigs underwent right internal thoracic artery to right coronary artery bypass grafting through a median sternotomy (group 1) with a novel magnetic vascular positioning system (MVP system; Ventrica, Inc, Fremont, Calif). Twenty-two pigs underwent left internal thoracic artery to left anterior descending artery grafting with the MVP anastomotic device through a left anterior minithoracotomy (group 2). This system consists of 2 pairs of elliptical magnetic implants and a deployment device. One pair of magnets forms the anastomotic docking port within the graft; the other pair forms an identical anastomotic docking port within the target vessel. The anastomosis is created when the 2 docking ports magnetically couple. Anastomotic patency was evaluated by means of angiography during the first postoperative week and at 1 month. Histologic studies were performed at different time points as late as 6 months.

RESULTS: Right internal thoracic artery to right coronary artery anastomoses and left internal thoracic artery to left anterior descending artery anastomoses were successfully performed with the system in all animals. The self-adherent and self-aligning properties of the implants allowed for immediate and secure approximation of the arteries (total anastomotic time between 2-3 minutes). Anastomoses were constructed without a stabilization platform. Five nondevice-related deaths occurred postoperatively. One-week angiography, performed in 35 surviving animals, showed a patent graft and anastomosis in all cases. The patency rate at 1 month was 97% (33/34). Histologic studies as late as 6 months demonstrated neointimal coverage of the magnets without any significant luminal obstruction. Histology also confirmed the presence of viable tissue between magnets.

CONCLUSION: The MVP anastomotic system uses magnetic force to create rapid and secure distal coronary artery anastomoses, which might facilitate minimally invasive and totally endoscopic coronary artery bypass surgery.





This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
K. E. Matschke, J. F. Gummert, S. Demertzis, U. Kappert, M. B. Anssar, F. Siclari, V. Falk, E. L. Alderman, C. Detter, H. Reichenspurner, et al.
The Cardica C-Port System: Clinical and angiographic evaluation of a new device for automated, compliant distal anastomoses in coronary artery bypass grafting surgery--A multicenter prospective clinical trial
J. Thorac. Cardiovasc. Surg., December 1, 2005; 130(6): 1645 - 1652.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
U. Klima, H. MacVaugh III, E. Bagaev, M. Maringka, S. Kirschner, J. Beilner, and A. Haverich
Magnetic Vascular Port in Minimally Invasive Direct Coronary Artery Bypass Grafting
Circulation, September 14, 2004; 110(11_suppl_1): II-55 - II-60.