JTCS Click here to go to SJM website.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Thierry Carrel
Friedrich Eckstein
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Carrel, T.
Right arrow Articles by Eckstein, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Carrel, T.
Right arrow Articles by Eckstein, F.
Related Collections
Right arrow Minimally invasive surgery

J Thorac Cardiovasc Surg 2004;127:1632-1640
© 2004 The American Association for Thoracic Surgery


Surgery for acquired cardiovascular disease

Clinical and angiographic results after mechanical connection for distal anastomosis in coronary surgery

Thierry Carrel, MDa,*, Lars Englberger, MDa, Dorothee Keller, RNa, Stephan Windecker, MDb, Bernhard Meier, MDb, Friedrich Eckstein, MDa

a Clinic for Cardiovascular Surgery, University Hospital Berne, Berne, Switzerland
b Division for Cardiology, University Hospital Berne, Berne, Switzerland

Read at the Twenty-ninth Annual Meeting of The Western Thoracic Surgical Association, Carlsbad, Calif, June 18-21, 2003.

Received for publication June 10, 2003; revisions received October 7, 2003; accepted for publication November 4, 2003.

* Address for reprints: Thierry Carrel, MD, Clinic for Cardiovascular Surgery, University Hospital, CH-3010 Berne, Switzerland
thierry.carrel{at}insel.ch

BACKGROUND: Sutureless anastomotic devices are of increasing interest in cardiovascular surgery. We investigated the stainless steel clip system of St Jude Medical/Anastomotic Technology Group (Maple Grove, Minn) to connect saphenous vein grafts with coronary arteries.

METHODS: Forty-five patients were enrolled in this feasibility study performed on patients who had on-pump coronary artery bypass grafting, but 32 patients only received 1 distal anastomosis with this investigational device (2.5 mm [n = 14] and 2.0 mm [n = 18]). Thirteen were excluded because target vessels were too small, calcified, or tortuous. The system consists of an expandable clip mounted on a balloon catheter; delivery is obtained during balloon inflation. The main differences between the 2.5-mm and 2.0-mm devices are different loading and deployment in smaller coronary arteries for the 2.0-mm device.

RESULTS: A connecting device was deployed on the right coronary artery in 14 patients, the posterior descending branch in 12 patients, the obtuse marginal in 5 patients, and the posterolateral branch in 1 patient. Perfect hemostasis of the sutureless connector anastomosis was obtained in 28 patients. Three connectors were removed because of minor leakage at the connection site, and 1 connector was removed because of mismanipulation after successful deployment. Hand-sewn anastomosis was performed at the same arteriotomy site. Intraoperative flow was assessed by the transit time method and averaged 71 ± 24 mL/min. One patient died of neurologic injury; the connector was patent at autopsy. One patient had a perioperative myocardial infarction. There was no adverse cardiac event in the remaining patients. All patients underwent clinical follow-up after 6 and 12 months and 35 angiograms were available in 21 patients: after 3 and 6 months, 17 anastomoses were patent and the saphenous vein graft was occluded in 4 patients.

CONCLUSIONS: The coronary connector system from St Jude Medical/Anastomotic Technology Group allows consistently uniform sutureless connection between the saphenous vein graft and coronary artery. Loading and deployment require careful training. This technology is under constant development and may give a significant boost to less invasive coronary revascularization techniques.





This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. D. Puskas, M. E. Halkos, H. Balkhy, M. Caskey, M. Connolly, J. Crouch, A. Diegeler, J. Gummert, W. Harringer, V. Subramanian, et al.
Evaluation of the PAS-Port Proximal Anastomosis System in coronary artery bypass surgery (the EPIC trial)
J. Thorac. Cardiovasc. Surg., July 1, 2009; 138(1): 125 - 132.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
W. J.L. Suyker and C. Borst
Coronary Connector Devices: Analysis of 1,469 Anastomoses in 1,216 Patients
Ann. Thorac. Surg., May 1, 2008; 85(5): 1828 - 1836.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Vicol, S. Eifert, M. Oberhoffer, P. Boekstegers, and B. Reichart
Mid-term patency after magnetic coupling for distal bypass anastomosis in coronary surgery.
Ann. Thorac. Surg., October 1, 2006; 82(4): 1452 - 1456.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
W. J.L. Suyker, J. P. Matonick, P. T.W. Suyker, A. Brutel de la Riviere, M. P. Buijsrogge, R. P.J. Budde, C. W.J. Verlaan, G. Pasterkamp, P. F. Grundeman, and C. Borst
S2 Connector Versus Suture: Distal Coronary Anastomosis Remodeling, Patency, and Function in the Pig
Circulation, July 4, 2006; 114(1_suppl): I-390 - I-395.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
R. P.J. Budde, W. J.L. Suyker, P. T.W. Suyker, C. W.J. Verlaan, R. Meijer, C. Borst, and P. F. Grundeman
Quality assessment of distal S2AS connector anastomosis by 13MHz epicardial ultrasound
Eur. J. Cardiothorac. Surg., December 1, 2005; 28(6): 833 - 837.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
U. Klima, T. Kofidis, A. Boening, and A. Haverich
Long term angiographic monitoring reveals safety and efficacy of the Converge end-to-side anastomotic coupler
Interactive CardioVascular and Thoracic Surgery, December 1, 2005; 4(6): 505 - 508.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. Boening, F. Schoeneich, A. Lichtenberg, E. Bagaev, J. T. Cremer, and U. Klima
First clinical results with a 30{degrees} end-to-side coronary anastomosis coupler
Eur. J. Cardiothorac. Surg., May 1, 2005; 27(5): 876 - 881.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2004 by The American Association for Thoracic Surgery.