JTCS Tips for Better Browsing
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Luca Caprili
Dino Casarotto
Gino Gerosa
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bottio, T.
Right arrow Articles by Gerosa, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bottio, T.
Right arrow Articles by Gerosa, G.
Related Collections
Right arrow Cardiac - other

J Thorac Cardiovasc Surg 2004;128:457-462
© 2004 The American Association for Thoracic Surgery


Evolving technology

Small aortic annulus: The hydrodynamic performances of 5 commercially available bileaflet mechanical valves

Tomaso Bottio, MDa,*, Luca Caprili, MDa, Dino Casarotto, MDa, Gino Gerosa, MDa

a Department of Cardiovascular Surgery, University of Padua Medical School, Padua, Italy

Received for publication September 5, 2003; revisions received February 29, 2004; accepted for publication March 4, 2004.

* Address for reprints: Gino Gerosa, MD, Chief, Department of Cardiovascular Surgery, Via Giustiniani, 2, 35100, Padova, Italy
gino.gerosa{at}unipd.it

OBJECTIVE: Hemodynamic performances of mechanical valve prostheses in patients with aortic valve stenosis and a small aortic annulus are crucial. We analyzed the in vitro hydrodynamics of 5 currently available bileaflet mechanical prostheses that fitted a 21-mm-diameter valve holder of a Sheffield pulse duplicator.

METHODS: Three samples of 5 high-performance production-quality prostheses, including the sewing ring cuffs, were tested in the aortic chamber of a Sheffield pulse duplicator. Sizes of the prostheses fitting the 21-mm valve holder were as follows: 18-mm ATS, 19-mm SJM Regent, 19-mm Sorin Bicarbon Slimline, 19-mm On-X, and 21-mm Carbomedics Top Hat. The tests were carried out at a fixed pulse rate (70 beats/min) and at increasing cardiac outputs of 2, 4, 5, and 7 L/min. Each valve was tested 10 times for each different cardiac output. This resulted in a total of 40 tests for each valve and 120 tests for each valve model. The aortic pressure was set at 120/80 mm Hg (mean pressure, 100 mm Hg) throughout the experiment for all cardiac outputs. Forward flow pressure decrease, total regurgitant volume, closing and leakage volumes, effective orifice area, and stroke work loss were recorded while the valve operated under each cardiac output.

RESULTS: The SJM Regent valve and the Sorin Bicarbon Slimline prosthesis showed the lowest mean and peak gradients at increasing cardiac outputs. The closure volume was higher for the SJM Regent and Sorin Bicarbon Slimline prostheses, unlike with the ATS prosthesis at 7 L/min of cardiac output. The ATS and SJM Regent prostheses showed the largest regurgitant volume, whereas the Sorin Bicarbon Slimline prosthesis showed the lowest regurgitant volume. The calculated effective orifice area and stroke work loss were significantly better with the SJM Regent and Sorin Bicarbon Slimline prostheses.

CONCLUSION: Assuming that the 21-mm valve holder in which all the tested prostheses were accommodated is comparable with a defined aortic valve size, this hydrodynamic evaluation model allowed us to compare the efficiency of currently available valve prostheses, and among these, the SJM Regent and the Sorin Bicarbon Slimline exhibited the best performances.





This article has been cited by other articles:


Home page
ICVTSHome page
T. Bottio, V. Tarzia, G. Rizzoli, and G. Gerosa
The changing spectrum of bioprostheses hydrodynamic performance: considerations on in-vitro tests
Interactive CardioVascular and Thoracic Surgery, October 1, 2008; 7(5): 750 - 754.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Roedler, M. Czerny, J. Neuhauser, D. Zimpfer, R. Gottardi, D. Dunkler, E. Wolner, and M. Grimm
Mechanical Aortic Valve Prostheses in the Small Aortic Root: Top Hat Versus Standard CarboMedics Aortic Valve
Ann. Thorac. Surg., July 1, 2008; 86(1): 64 - 70.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
R. Garcia Fuster, V. Estevez, I. Rodriguez, S. Canovas, O. Gil, F. Hornero, and J. Martinez-Leon
Prosthesis patient mismatch with latest generation supra-annular prostheses. The beginning of the end?
Interactive CardioVascular and Thoracic Surgery, August 1, 2007; 6(4): 462 - 469.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. Gerosa, V. Tarzia, G. Rizzoli, and T. Bottio
Small aortic annulus: The hydrodynamic performances of 5 commercially available tissue valves
J. Thorac. Cardiovasc. Surg., May 1, 2006; 131(5): 1058 - 1064.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
Inappropriate surgical technique or prosthesis malfunctioning?
J. Thorac. Cardiovasc. Surg., March 1, 2006; 131(3): 759 - 760.



Home page
Eur. J. Cardiothorac. Surg.Home page
J. M. Bernal, J. Lorca, D. Prieto-Salceda, I. Pulitani, A. Ponton, I. Garcia, and J. M. Revuelta
Performance at 10 years of the CarboMedics 'Top-Hat' valve. Postclamping time is a predictor of mortality
Eur. J. Cardiothorac. Surg., February 1, 2006; 29(2): 144 - 149.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. H. Rahimtoola
The Year in Valvular Heart Disease
J. Am. Coll. Cardiol., January 17, 2006; 47(2): 427 - 439.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2004 by The American Association for Thoracic Surgery.