J Thorac Cardiovasc Surg 2005;130:99-106
© 2005 The American Association for Thoracic Surgery
Cardiopulmonary Support and Physiology |
Division of Cardiovascular Surgery, Department of Surgery, Toronto General Research Institute, Toronto General Hospital, University of Toronto, Toronto, Ontario, Canada.
Received for publication April 21, 2004; revisions received September 20, 2004; accepted for publication October 1, 2004. * Address for reprints: Ren-Ke Li, MD, PhD, Toronto General Hospital, NU 1-115A, 200 Elizabeth St, Toronto, Ontario M5 2C4, Canada (Email: renkeli{at}uhnres.utoronto.ca).
OBJECTIVES: Left ventricular assist devices are proposed as a bridge to recovery, but recurrent ventricular deterioration has limited this approach. We describe a new animal model that simulates the effects of left ventricular assist device unloading and then reloading after device removal. The model might facilitate the evaluation of interventions intended to prevent recurrent ventricular dysfunction.
METHODS: The hearts and lungs of Lewis rats were removed and transplanted into the abdomen of recipient rats by anastomosing the donors ascending aorta to the recipients abdominal aorta. The transplanted hearts were maintained unloaded for 2 weeks in 49 animals. Eighteen transplanted hearts were removed after 2 weeks of unloading. In 17 animals the donors right pulmonary artery was anastomosed to the recipients abdominal aorta to reload the heart for an additional 2 weeks. In 14 animals the hearts were maintained unloaded for 4 weeks (an additional 2 weeks). The unloaded and reloaded hearts were compared with normal rat hearts (n = 18).
RESULTS: In the unloaded hearts the left ventricular end-diastolic pressures remained low. The left ventricular systolic pressures were lower than the aortic pressures. The left ventricular weights (n = 8) and volumes (n = 4) remained significantly lower (P < .01) than in the normal hearts. Two weeks after reloading, the left ventricular end-diastolic pressure (n = 8) increased (P < .01), and the ventricle ejected. The left ventricular systolic pressures exceeded the aortic pressures. The left ventricular weights and volumes increased (P < .01) and approached those of normal hearts. Matrix metalloproteinase 9 (n = 6/group) levels decreased in the unloaded state (P = .02) and increased back to normal values after reloading.
CONCLUSIONS: This surgical model simulated left ventricular assist device unloading of the left ventricle. The second operation reloaded the left ventricle, which then enlarged. This model will permit the evaluation of adjunctive interventions, such as cell transplantation, intended to facilitate successful left ventricular assist device removal and prevent recurrent dilatation.
This article has been cited by other articles:
![]() |
J. Wang, M. Tsukashita, T. Nishina, A. Marui, E. Yoshikawa, H. Muranaka, S. Matsuoka, and T. Ikeda Chronic partial unloading restores beta-adrenergic responsiveness and reverses receptor downregulation in failing rat hearts. J. Thorac. Cardiovasc. Surg., February 1, 2009; 137(2): 465 - 470. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Wang, A. Marui, T. Ikeda, and M. Komeda Partial left ventricular unloading reverses contractile dysfunction and helps recover gene expressions in failing rat hearts Interactive CardioVascular and Thoracic Surgery, February 1, 2008; 7(1): 27 - 31. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |