JTCS Medtronic Endurant
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Hiroyuki Tsukui
Robert L. Kormos
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsukui, H.
Right arrow Articles by Kormos, R. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsukui, H.
Right arrow Articles by Kormos, R. L.
Related Collections
Right arrow Mechanical Circulatory Assistance

J Thorac Cardiovasc Surg 2007;134:114-123
© 2007 The American Association for Thoracic Surgery


Cardiopulmonary Support and Physiology

Cerebrovascular accidents in patients with a ventricular assist device

Hiroyuki Tsukui, MD, PhDa,*, Adib Abla, MSa, Jeffrey J. Teuteberg, MDb, Dennis M. McNamara, MDb, Michael A. Mathier, MDb, Linda M. Cadaret, MDb, Robert L. Kormos, MDa

a Division of Cardiothoracic Surgery, Heart, Lung, and Esophageal Institute, University of Pittsburgh Medical Center, Pittsburgh Pa.
b Division of Cardiology, University of Pittsburgh Medical Center, Pittsburgh Pa.

Poster Presentation at the Twenty-sixth Annual Meeting of the Western Thoracic Surgical Association, Sun Valley, Idaho, June 21–24, 2006.

Received for publication June 19, 2006; revisions received December 2, 2006; accepted for publication February 14, 2007.

* Address for reprints: Hiroyuki Tsukui, MD, PhD, Division of Cardiothoracic Surgery, Heart, Lung, and Esophageal Institute, University of Pittsburgh Medical Center, Suite C-700, 200 Lothrop St, Pittsburgh PA, 15213. (Email: tsukuih{at}upmc.edu).

Objective: A cerebrovascular accident is a devastating adverse event in a patient with a ventricular assist device. The goal was to clarify the risk factors for cerebrovascular accident.

Methods: Prospectively collected data, including medical history, ventricular assist device type, white blood cell count, thrombelastogram, and infection, were reviewed retrospectively in 124 patients.

Results: Thirty-one patients (25%) had 48 cerebrovascular accidents. The mean ventricular assist device support period was 228 and 89 days in patients with and without cerebrovascular accidents, respectively (P < .0001). Sixty-six percent of cerebrovascular accidents occurred within 4 months after implantation. Actuarial freedom from cerebrovascular accident at 6 months was 75%, 64%, 63%, and 33% with the HeartMate device (Thoratec Corp, Pleasanton, Calif), Thoratec biventricular ventricular assist device (Thoratec Corp), Thoratec left ventricular assist device (Thoratec), and Novacor device (WorldHeart, Oakland, Calif), respectively. Twenty cerebrovascular accidents (42%) occurred in patients with infections. The mean white blood cell count at the cerebrovascular accident was greater than the normal range in patients with infection (12,900/mm3) and without infection (9500/mm3). The mean maximum amplitude of the thrombelastogram in the presence of infection (63.6 mm) was higher than that in the absence of infection (60.7 mm) (P = .0309).

Conclusions: The risk of cerebrovascular accident increases with a longer ventricular assist device support period. Infection may activate platelet function and predispose the patient to a cerebrovascular accident. An elevation of the white blood cell count may also exacerbate the risk of cerebrovascular accident even in patients without infection. Selection of device type, prevention of infection, and meticulous control of anticoagulation are key to preventing cerebrovascular accident.



Abbreviations and Acronyms CVA = cerebrovascular accident; HIT = heparin-induced thrombocytopenia; INR = international normalized ratio; LVAD = left ventricular assist device; MA = maximum amplitude; POD = postoperative day; PTT = prothrombin time; TEG = thromboelastogram; TIA = transient ischemic attack; VAD = ventricular assist device





This article has been cited by other articles:


Home page
World Journal for Pediatric and Congenital Heart SurgeryHome page
D. A. Hehir, R. A. Niebler, C. C. Brabant, J. S. Tweddell, and N. S. Ghanayem
Intensive Care of the Pediatric Ventricular Assist Device Patient
World Journal for Pediatric and Congenital Heart Surgery, January 1, 2012; 3(1): 58 - 66.
[Abstract] [Full Text] [PDF]


Home page
The Annals of PharmacotherapyHome page
C. R. Ensor, C. A. Paciullo, W. D. Cahoon Jr, and P. E. Nolan Jr
Pharmacotherapy for Mechanical Circulatory Support: A Comprehensive Review
Ann. Pharmacother., January 1, 2011; 45(1): 60 - 77.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. R. Wilson, M. M. Givertz, G. C. Stewart, and G. H. Mudge Jr
Ventricular Assist Devices: The Challenges of Outpatient Management
J. Am. Coll. Cardiol., October 27, 2009; 54(18): 1647 - 1659.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
E. A. Genovese, M. A. Dew, J. J. Teuteberg, M. A. Simon, J. Kay, M. P. Siegenthaler, J. K. Bhama, C. A. Bermudez, K. L. Lockard, S. Winowich, et al.
Incidence and Patterns of Adverse Event Onset During the First 60 Days After Ventricular Assist Device Implantation
Ann. Thorac. Surg., October 1, 2009; 88(4): 1162 - 1170.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. E. Sandner, D. Zimpfer, P. Zrunek, A. Rajek, H. Schima, D. Dunkler, M. Grimm, E. Wolner, and G. M. Wieselthaler
Renal Function and Outcome After Continuous Flow Left Ventricular Assist Device Implantation
Ann. Thorac. Surg., April 1, 2009; 87(4): 1072 - 1078.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
W. T. Mahle, G. Ianucci, R. N. Vincent, and K. R. Kanter
Costs Associated With Ventricular Assist Device Use in Children
Ann. Thorac. Surg., November 1, 2008; 86(5): 1592 - 1597.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2007 by The American Association for Thoracic Surgery.