JTCS Sign the Guestbook
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Farhad Bakhtiary
Omer Dzemali
Anton Moritz
Peter Kleine
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bakhtiary, F.
Right arrow Articles by Kleine, P.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Bakhtiary, F.
Right arrow Articles by Kleine, P.

J Thorac Cardiovasc Surg 2007;134:657-662
© 2007 The American Association for Thoracic Surgery


Surgery for Acquired Cardiovascular Disease

Opening and closing kinematics of fresh and calcified aortic valve prostheses: An in vitro study

Farhad Bakhtiary, MDa,*, Omer Dzemali, MDa, Ulrich Steinseiffer, PhDb, Christof Schmitz, PhDb, Birgit Glasmacher, PhDb, Anton Moritz, MD, PhDa, Peter Kleine, MD, PhDa

a Department of Thoracic and Cardiovascular Surgery of Johann Wolfgang Goethe University Hospital
b Frankfurt/Main, Germany; and Cardiovascular Engineering Group, Helmholtz Institute Aachen, Germany

Received for publication November 16, 2006; revisions received February 18, 2007; accepted for publication February 23, 2007.

* Address for reprints: Farhad Bakhtiary, MD, Department of Thoracic and Cardiovascular Surgery, Johann Wolfgang Geothe University Hospital, Theodor-Stern-Kai 7, 60596 Frankfurt/Main, Germany (Email: farhad{at}bakhtiary.de).

Objectives: In vitro testing of biologic valves has been performed using only fresh but treated valves suitable for patient implantation. The present study investigates changes in hemodynamic performance and leaflet kinematics in progressively calcified porcine and pericardial aortic valve prostheses.

Methods: Edwards Perimount Magna (Edwards Lifesciences, Irvine, Calif) (n = 5) and Medtronic Mosaic Ultra (Medtronic Inc, Minneapolis, Minn) (n = 5) heart valves (23 mm) were investigated in an artificial circulation system (70 beats/min, cardiac output 5 L/min). Leaflet kinematics were visualized with a high-speed camera (3000 frames/sec). Valves were then exposed to a calcium-phosphate solution at a constant pulse rate of 300 beats/min for a total of 6 weeks. Repeated testing was performed after 1, 2, 3, 4, and 6 weeks of calcification. The calcification process might not be similar to in vivo performance.

Results: Initially, the Perimount Magna valves demonstrated lower pressure gradients compared with the Mosaic Ultra valves (9.7 ± 0.36 mm Hg vs 14.0 ± 1.16 mm Hg), but they showed higher closing volume and leakage flow. Total energy loss was equivalent after 1 week of calcification. Perimount Magna valves calcified significantly faster and more severely, leading to an increase in gradients and closure volume. Leaflet kinematics showed progressively longer opening and closing times for the pericardial valves (closing time Perimount Magna 135 ± 11 msec vs Mosaic Ultra 85 ± 9 msec after 6 weeks).

Conclusions: On the basis of visual inspection, despite the new ThermaFix (Edwards Lifesciences) tissue treatment, the Perimount Magna pericardial valves calcified in vitro faster and more severely than did the Mosaic Ultra porcine valves, which demonstrated a more constant performance throughout the calcification process. Leaflet kinematics showed a progressive prolongation of opening and closing times for pericardial valves, leading to higher closing volume.



Abbreviations and Acronyms EOA = effective orifice area; LV = left ventricle





This article has been cited by other articles:


Home page
CirculationHome page
D. J. Ruzicka, I. Hettich, A. Hutter, S. Bleiziffer, C. C. Badiu, R. Bauernschmitt, R. Lange, and W. B. Eichinger
The Complete Supraannular Concept: In Vivo Hemodynamics of Bovine and Porcine Aortic Bioprostheses
Circulation, September 15, 2009; 120(11_suppl_1): S139 - S145.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
F. Bakhtiary, O. Dzemali, U. Steinseiffer, C. Schmitz, B. Glasmacher, A. Moritz, and P. Kleine
Hydrodynamic comparison of biological prostheses during progressive valve calcification in a simulated exercise situation. An in vitro study
Eur. J. Cardiothorac. Surg., November 1, 2008; 34(5): 960 - 963.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
T. Bottio, V. Tarzia, G. Rizzoli, and G. Gerosa
The changing spectrum of bioprostheses hydrodynamic performance: considerations on in-vitro tests
Interactive CardioVascular and Thoracic Surgery, October 1, 2008; 7(5): 750 - 754.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. El Oakley, P. Kleine, and D. S. Bach
Choice of Prosthetic Heart Valve in Today's Practice
Circulation, January 15, 2008; 117(2): 253 - 256.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2007 by The American Association for Thoracic Surgery.