JTCS Click here to go to SJM website.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Pasquale Totaro
Vincenzo Argano
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Totaro, P.
Right arrow Articles by Argano, V.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Totaro, P.
Right arrow Articles by Argano, V.

J Thorac Cardiovasc Surg 2007;134:697-701
© 2007 The American Association for Thoracic Surgery


Surgery for Acquired Cardiovascular Disease

Patient–prosthesis mismatch after mitral valve replacement: Myth or reality?

Pasquale Totaro, MDa,*, Vincenzo Argano, MDb

a Cardiac Surgery Division, Civic Hospital, Brescia, Italy
b Department of Thoracic and Cardiovascular Surgery, Villa Maria Eleonora Hospital, Palermo, Italy.

Received for publication February 2, 2007; revisions received March 19, 2007; accepted for publication April 11, 2007.

* Address for reprints: Pasquale Totaro, MD, Via San Vincenzo, 38, 20123 Milan, Italy. (Email: ptotaro{at}yahoo.com).

Objective: Determining the risk of patient–prosthesis mismatch after mitral valve replacement is still controversial. In this study, we aimed to clarify incidence and clinical implications of such a complication. The accuracy of preoperative prediction of patient–prosthesis mismatch using published in vitro hemodynamic parameters was also investigated.

Methods: Ninety-two patients who underwent mitral valve replacement and received Carpentier–Edwards stented bioprosthesis (Edwards Lifesciences, LLC, Irvine Calif) were enrolled. Hemodynamic performances were evaluated at discharge, and the incidence of in vivo patient–prosthesis mismatch (indexed effective orifice area ≤1.2 cm2/m2) was evaluated. Correlation between in vivo patient–prosthesis mismatch and predicted patient–prosthesis mismatch, based on previously published in vitro hemodynamic parameters, was also investigated.

Results: Five patients died within 30 days of the operation (5.4% mortality). Mean prosthesis size was 29.8 ± 2. Mean postoperative effective orifice area and indexed effective orifice area (2.5 ± 0.8 cm2 and 1.5 ± 0.4 cm2/m2, respectively) compared favorably with those predicted in vitro (2.2 ± 0.7 cm2 and 1.3 ± 0.5 cm2/m2, respectively). In the subgroup of patients receiving prosthesis size of 27 or smaller, the difference reached statistical significance (2.47 ± 0.83 and 1.61 ± 0.7 for postoperative and predicted effective orifice areas, respectively; P < .001). Postoperative patient–prosthesis mismatch was recorded in 8 patients (8.6%), comparing favorably with the predicted patient–prosthesis mismatch (39% for overall population and 80% for patients receiving prosthesis size ≤ 27). No significant correlation between size of prosthesis and early hemodynamic and clinical outcomes was shown.

Conclusions: In our study, stented mitral bioprostheses showed satisfactory postoperative hemodynamic performance, even in smaller prosthesis sizes (≤27 mm). Risk of in vivo postoperative patient–prosthesis mismatch seems to be less relevant than preoperative risk prediction based on in vitro data. Further studies are needed to evaluate the potential clinical impact of mitral patient–prosthesis mismatch.



Abbreviations and Acronyms EOA = effective orifice area; MEOA = mitral effective orifice area; MEOAI = indexed mitral effective orifice area; MVR = mitral valve replacement; PPM = patient–prosthesis mismatch





This article has been cited by other articles:


Home page
HeartHome page
J.-L. Monin
Prosthesis-patient mismatch: myth or reality?
Heart, June 1, 2009; 95(11): 948 - 952.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. Tanne, L. Kadem, R. Rieu, and P. Pibarot
Hemodynamic impact of mitral prosthesis-patient mismatch on pulmonary hypertension: an in silico study
J Appl Physiol, December 1, 2008; 105(6): 1916 - 1926.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. Totaro and V. Argano
Reply to the Editor.
J. Thorac. Cardiovasc. Surg., February 1, 2008; 135(2): 465 - 466.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. Pibarot, J. Magne, and J. G. Dumesnil
Prosthesis-patient mismatch after mitral valve replacement: back to reality.
J. Thorac. Cardiovasc. Surg., February 1, 2008; 135(2): 464 - 465.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2007 by The American Association for Thoracic Surgery.