J Thorac Cardiovasc Surg 2007;134:697-701
© 2007 The American Association for Thoracic Surgery
Surgery for Acquired Cardiovascular Disease |
a Cardiac Surgery Division, Civic Hospital, Brescia, Italy
b Department of Thoracic and Cardiovascular Surgery, Villa Maria Eleonora Hospital, Palermo, Italy.
Received for publication February 2, 2007; revisions received March 19, 2007; accepted for publication April 11, 2007. * Address for reprints: Pasquale Totaro, MD, Via San Vincenzo, 38, 20123 Milan, Italy. (Email: ptotaro{at}yahoo.com).
Objective: Determining the risk of patient–prosthesis mismatch after mitral valve replacement is still controversial. In this study, we aimed to clarify incidence and clinical implications of such a complication. The accuracy of preoperative prediction of patient–prosthesis mismatch using published in vitro hemodynamic parameters was also investigated.
Methods: Ninety-two patients who underwent mitral valve replacement and received Carpentier–Edwards stented bioprosthesis (Edwards Lifesciences, LLC, Irvine Calif) were enrolled. Hemodynamic performances were evaluated at discharge, and the incidence of in vivo patient–prosthesis mismatch (indexed effective orifice area
1.2 cm2/m2) was evaluated. Correlation between in vivo patient–prosthesis mismatch and predicted patient–prosthesis mismatch, based on previously published in vitro hemodynamic parameters, was also investigated.
Results: Five patients died within 30 days of the operation (5.4% mortality). Mean prosthesis size was 29.8 ± 2. Mean postoperative effective orifice area and indexed effective orifice area (2.5 ± 0.8 cm2 and 1.5 ± 0.4 cm2/m2, respectively) compared favorably with those predicted in vitro (2.2 ± 0.7 cm2 and 1.3 ± 0.5 cm2/m2, respectively). In the subgroup of patients receiving prosthesis size of 27 or smaller, the difference reached statistical significance (2.47 ± 0.83 and 1.61 ± 0.7 for postoperative and predicted effective orifice areas, respectively; P < .001). Postoperative patient–prosthesis mismatch was recorded in 8 patients (8.6%), comparing favorably with the predicted patient–prosthesis mismatch (39% for overall population and 80% for patients receiving prosthesis size
27). No significant correlation between size of prosthesis and early hemodynamic and clinical outcomes was shown.
Conclusions: In our study, stented mitral bioprostheses showed satisfactory postoperative hemodynamic performance, even in smaller prosthesis sizes (
27 mm). Risk of in vivo postoperative patient–prosthesis mismatch seems to be less relevant than preoperative risk prediction based on in vitro data. Further studies are needed to evaluate the potential clinical impact of mitral patient–prosthesis mismatch.
This article has been cited by other articles:
![]() |
J.-L. Monin Prosthesis-patient mismatch: myth or reality? Heart, June 1, 2009; 95(11): 948 - 952. [Full Text] [PDF] |
||||
![]() |
D. Tanne, L. Kadem, R. Rieu, and P. Pibarot Hemodynamic impact of mitral prosthesis-patient mismatch on pulmonary hypertension: an in silico study J Appl Physiol, December 1, 2008; 105(6): 1916 - 1926. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Totaro and V. Argano Reply to the Editor. J. Thorac. Cardiovasc. Surg., February 1, 2008; 135(2): 465 - 466. [Full Text] [PDF] |
||||
![]() |
P. Pibarot, J. Magne, and J. G. Dumesnil Prosthesis-patient mismatch after mitral valve replacement: back to reality. J. Thorac. Cardiovasc. Surg., February 1, 2008; 135(2): 464 - 465. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |