JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Yoshikatsu Saiki
Koichi Tabayashi
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Masuda, S.
Right arrow Articles by Tabayashi, K.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Masuda, S.
Right arrow Articles by Tabayashi, K.

J Thorac Cardiovasc Surg 2007;134:723-730
© 2007 The American Association for Thoracic Surgery


Evolving Technology

Trial of new vascular clips for aortic anastomosis in a canine model

Shinya Masuda, MDa,*, Yoshikatsu Saiki, MDa, Satoshi Kawatsu, MDa, Ichiro Yoshioka, MDa, Hidenori Fujiwara, MDa, Shunsuke Kawamoto, MDa, Sadahiro Sai, MDa, Atsushi Iguchi, MDa, Naoya Sakamoto, PhDb, Toshiro Ohashi, PhDb, Masaaki Sato, PhDb, Koichi Tabayashi, MDa

a Department of Cardiovascular Surgery, Tohoku University, Sendai, Japan
b School of Mechanical Engineering, Tohoku University, Sendai, Japan.

Received for publication December 6, 2006; revisions received April 18, 2007; accepted for publication April 23, 2007.

* Address for reprints: Shinya Masuda, MD, Department of Cardiovascular Surgery, Graduate School of Medicine, Tohoku University, 1-1 Seiryou-machi, Aoba-ku, Sendai, Japan 980-8574. (Email: shinyamasuda-ths{at}umin.ac.jp).

Objectives: We created a new vascular clip designed for aortic surgery. The purposes of this investigation were to examine surgical applicability in a clinically relevant aortic replacement model and to assess biomechanical strength of the clipped anastomosis and serial histologic changes in the clipped anastomotic site.

Methods: Twenty-one beagles underwent descending thoracic aortic replacement. Distal anastomosis was performed with the new clips, mimicking the cuffed anastomosis technique, and proximal anastomosis was carried out by conventional suture anastomosis. Tissue specimens of the anastomotic sites were harvested at 1, 3, 6, and 12 months postoperatively for examination.

Results: There was no significant difference in the time required to carry out clip anastomosis (12.2 ± 1.3 minutes) and suture anastomosis (13.7 ± 0.9 minutes; P = .38). Neither type of anastomotic site was disrupted by raising the intraluminal pressure to 280 mm Hg. Microscopically, the areas of aortic wall compressed by vascular clips appeared as hyalinized areas adjacent to surrounding collagen fibers, with no significant infiltration of inflammatory cells. Identical histologic changes were observed at the site of the sutured anastomosis. The media at the clipped anastomosis site was significantly thinner than that at the sutured anastomosis site at 1 month after the operation. However, there was no significant difference in the thickness of the media at 3 months.

Conclusions: The new vascular clips were effective in this clinically relevant model, with appropriate biomechanical strength, and the anastomotic sites underwent similar histologic changes to those observed after suture anastomosis.



Abbreviations and Acronyms ANOVA = analysis of variance; EM = elastica–Masson; ePTFE = expanded polytetrafluoroethylene; HE = hematoxylin–eosin