JTCS Click here to go to SJM website.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Benjamin Sun
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Raman, S. V.
Right arrow Articles by Sun, B.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Raman, S. V.
Right arrow Articles by Sun, B.
Related Collections
Right arrow Mechanical Circulatory Assistance

J Thorac Cardiovasc Surg 2009;137:1213-1217
© 2009 The American Association for Thoracic Surgery


Cardiopulmonary Support

Dynamic computed tomography to determine cardiac output in patients with left ventricular assist devices

Subha V. Raman, MD, MSEE*, Tam Tran, BS, Orlando P. Simonetti, PhD, Benjamin Sun, MD

The Ohio State University, Columbus, Ohio

Received for publication July 30, 2008; revisions received October 1, 2008; accepted for publication October 9, 2008.

* Address for reprints: Subha V. Raman, MD, MSEE, The Ohio State University Davis Heart and Lung Research Institute, 473 West 12th Ave, Suite 200, Columbus, OH 43210. (Email: raman.1{at}osu.edu).

Objective: The purpose of this study was to develop and test a novel, noninvasive means of estimating cardiac output in patients with continuous-flow left ventricular assist devices.

Methods: Based on the indicator dilution principle, we estimated cardiac output from signal intensity versus time recordings during first-pass imaging with contrast-enhanced computed tomography. To account for recirculation, a gamma variate function was modified to model the indicator concentration curve. A proportionality constant for 64-slice computed tomography data acquisition was derived relating computed tomography Hounsfield units to indicator concentration. Validity of the equation was tested in ambulatory patients with continuous-flow left ventricular assist devices who underwent simultaneous computed tomography and Swan-Ganz catheter thermodilution-based measurement of cardiac output at various left ventricular assist device rpm settings. Agreement between measurements was testing using kappa statistic.

Results: Pairwise comparison of calculated output using the dynamic computed tomography test bolus technique versus thermodilution output measurements yielded good agreement (P = .03). The output calculated using dynamic computed tomography underestimated the thermodilution output measurement by 0.54 ± 0.37 L/min (95% confidence interval, 0.66–0.94).

Conclusions: Noninvasive estimation of cardiac output from left ventricular assist devices is feasible using first-pass dynamic computed tomography. By affording simultaneous good visualization of the device in situ, computed tomography may be useful for noninvasive assessment of location and function of ambulatory patients with left ventricular assist devices.



Abbreviations and Acronyms CT = computed tomography; VAD = ventricular assist device