JTCS Click here to go to SJM website.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


  Click here to read this article as a CME activity


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Daniel J. DiBardino
Doff B. McElhinney
Aditya K. Kaza
John E. Mayer, Jr.
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Google Scholar
Right arrow Articles by DiBardino, D. J.
Right arrow Articles by Mayer, J. E.
PubMed
Right arrow Articles by DiBardino, D. J.
Right arrow Articles by Mayer, J. E., Jr.
Related Collections
Right arrow Congenital - acyanotic

J Thorac Cardiovasc Surg 2009;137:1334-1341
© 2009 The American Association for Thoracic Surgery


Congenital Heart Disease

Analysis of the US Food and Drug Administration Manufacturer and User Facility Device Experience database for adverse events involving Amplatzer septal occluder devices and comparison with the Society of Thoracic Surgery congenital cardiac surgery database

Daniel J. DiBardino, MDa,*, Doff B. McElhinney, MDb, Aditya K. Kaza, MDa, John E. Mayer, Jr., MDa

a Department of Cardiac Surgery, Children' s Hospital Boston, Harvard Medical School, Boston, Mass
b Department of Cardiology, Children's Hospital Boston, Harvard Medical School, Boston, Mass

Received for publication May 25, 2008; revisions received December 26, 2008; accepted for publication February 16, 2009.

* Address for reprints: Daniel J. DiBardino, MD, Cardiac Surgery, Children' s Hospital Boston, 300 Longwood Avenue, Boston, MA 02215. (Email: ddibardino{at}partners.org).

Objective: Amplatzer (AGA Medical Corporation, Plymouth, Minn) septal and vascular occluder devices have significantly altered the care of patients with congenital heart disease. The relative frequency and consequence of complications resulting from the attempted placement of such devices, however, have not been well assessed. The purpose of this study is to use large databases to assess the frequency and severity of such complications and compare them with those of surgical atrial septal defect closure.

Methods: The US Food and Drug Administration Manufacturer and User Facility Device Experience database was quarried for all adverse events for Amplatzer septal occluder devices, which were categorized and analyzed with particular emphasis on management and outcome. The Society of Thoracic Surgery database was likewise quarried for the same data regarding atrial septal defect closures over a contemporaneous time period. By using a literature-derived denominator for total Amplatzer implant numbers, the results of the 2 therapies were compared.

Results: Since July 1, 2002, 223 adverse events in patients undergoing Amplatzer atrial septal defect closure were submitted to the Food and Drug Administration, resulting in 17 deaths (7.6%) and 152 surgical rescue operations (68.2%). Society of Thoracic Surgery data demonstrated 1537 primary operations with 2 deaths (0.13%) and 6 reoperations (0.39%). By extrapolating on published estimates of Amplatzer implantation to provide an implant denominator (n = 18,333), there was no difference between overall mortality for surgical (0.13%) and device closure (0.093%, P = .649). Rescue operation for device adverse events (0.83%) was 2.1 times more likely than reoperation for surgical closure (0.39%, P = .063). Mortality per adverse event was higher for device closure (7.6%) than for surgical closure (1.2%, P = .004), and the need for surgery per adverse event was higher for device closure (68.2%) than for surgical closure (3.6%, P < .001). The mortality for surgical management of a device adverse event (2.6%) was 20-fold higher than for primary elective atrial septal defect closure (0.13%, P < .0001).

Conclusion: Overall crude mortality for device and surgical closure atrial septal defect closure is equivalent, and the need for subsequent operation (surgical rescue) is more common in patients undergoing device closure than reoperation is in patients undergoing surgical closure. Complications from device closure tend to be serious and most often require urgent or emergency operative management, whereas the mortality for surgical management of a device complication appears higher than that of elective atrial septal defect closure. Further information is required in the form of postmarketing surveillance, such as a mandatory user registry with periodic end-user notification.



Abbreviations and Acronyms AE = adverse event; ASD = atrial septal defect; MAUDE = Manufacturer and User Facility Device Experience; PER = perforation/erosion/rupture; PFO = patent foramen ovale; STS = Society of Thoracic Surgery; USFDA = US Food and Drug Administration





This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. J. DiBardino
Clarification of statements made regarding investigation into Amplatzer device complication incidence and comparison with the Society of Thoracic Surgery database.
J. Thorac. Cardiovasc. Surg., September 1, 2009; 138(3): 784 - 785.
[Full Text] [PDF]