The Journal of Thoracic and Cardiovascular Surgery, Vol 74, 651-652, Copyright © 1977 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association
Median sternotomy closure with running wire: a simplified method
PA Rubio, GA Guinn, K Bahadorzadeh and AC Sandoval
A method of median sternotomy closure which utilizes running wire is
described here. We believe this method shortens the surgical time involved
in closing the chest and also that it is a safe method which provides
significant saving of wire material so that it can be accomplished
generally with one No. 20 stainless steel wire.