JTCS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yipintsoi, T.
Right arrow Articles by Veith, F. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yipintsoi, T.
Right arrow Articles by Veith, F. J.

The Journal of Thoracic and Cardiovascular Surgery, Vol 78, 39-43, Copyright © 1979 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Differential lung blood flows in experimental unilateral emphysema: nonvalidity of perfusion scans

T Yipintsoi, L Cioffiro, K Pinsker, C Montefusco, P Bardfeld and FJ Veith

As part of an evaluation of the effects of left lung transplantation in dogs with papain emphysema of the right lung, differential lung blood flows were estimated by in vivo scintiscan of 99Mc-macroaggregated albumin (99mTc-MAA) and, after sacrifice, by direct counting of isotopically labeled carbonized microspheres. In six dogs, percentage flow to the right lung was calculated at the following four times: before and after induction of papain emphysema and 2 and 6 weeks after left lung autotransplantation. After the induction of right lung emphysema, the right lung in four of six animals continued to receive more than 50 percent of the total pulmonary blood flow. No correlation could be established between right lung blood flow determined by carbonized microsphere distribution (true right lung blood flow) and the flow determined by anterior and posterior scintiscans (apparent right lung blood flow). This discrepancy was caused by gross distortion of the right, emphysematous lungs, which had herniated into the left hemithoraces. This herniation was demonstrated by coronal slices taken through the thoraces of two additional dogs with right lung emphysema that were given radiolabeled carbonized microspheres and 99Tc-MAA and frozen after sacrifice. These results indicate that external scintiscans for which the particulate distribution technique are used are invalid in circumstances of altered lung geometry.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
K. W. Marck, D. A. Piers, and C. R. H. Wildevuur
Lung Transplantation in the Rat: II. Lung Perfusion Scintigraphy in Normal and Left Lung-Transplanted Rats
Ann. Thorac. Surg., July 1, 1982; 34(1): 81 - 88.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1979 by The American Association for Thoracic Surgery.