JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by O'Neill, M. J.
Right arrow Articles by Waldhausen, J. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by O'Neill, M. J., Jr
Right arrow Articles by Waldhausen, J. A.

The Journal of Thoracic and Cardiovascular Surgery, Vol 81, 686-690, Copyright © 1981 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

A rationale for the use of sequential coronary artery bypass grafts

MJ O'Neill Jr, PD Wolf, TK O'Neill, RM Montesano and JA Waldhausen

The use of sequential coronary artery bypass grafts has been advocated because of improved graft runoff and increased blood flow through the graft with this technique. To examine the influence of runoff, quantitated in terms of coronary vascular resistance, on the velocity of blood flow through coronary artery bypass grafts, we made two sets of simultaneous pressure and flow measurements in 106 single grafts and in 35 double sequential grafts. The first set of measurements was obtained following the aortic anastomosis and the second set of measurements was made following completion of the coronary anastomosis. Resistance of the coronary bed was calculated from the two sets of measurements. The velocity of blood flow through the grafts was calculated from vein graft diameter and the second flow measurement. No significant difference was found between the diameter of single vein grafts (4.0 +/- 0.05 mm.) and sequential vein grafts (4.1 +/- 0.09 nm.). Coronary vascular resistance in the sequential grafts (100.0 +/- 15.6 RU) was lower than that in single grafts (174.6 +/- 14.6 RU, p = 0.001). Velocity of blood flow through the proximal segment of the sequential grafts (11.1 +/- 1.1 cm/sec) was higher than that through single grafts (7.5 +/- 0.6 cm/sec, p = 0.003). The proximal segment of the sequential bypass graft has a higher velocity of blood flow than that seen in a single bypass graft. To obtain maximum hemodynamic advantage with the possibility of improving long-term patency rates, it is advisable to use the smaller coronary artery for the proximal sequential anastomosis.


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. Dion, D. Glineur, D. Derouck, R. Verhelst, P. Noirhomme, G. El Khoury, E. Degrave, and C. Hanet
Complementary saphenous grafting: Long-term follow-up
J. Thorac. Cardiovasc. Surg., August 1, 2001; 122(2): 296 - 304.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
K. M. Vural, E. Sener, and O. Tasdemir
Long-term patency of sequential and individual saphenous vein coronary bypass grafts
Eur. J. Cardiothorac. Surg., February 1, 2001; 19(2): 140 - 144.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
B. L. van Brussel, H. W. M. Plokker, A. A. Voors, J. M. P. G. Ernst, J. C. Kelder, P. J. Knaepen, and F. E. E. Vermeulen
DIFFERENT CLINICAL OUTCOME IN CORONARY ARTERY BYPASS WITH SINGLE AND SEQUENTIAL VEIN GRAFTS: A FIFTEEN-YEAR FOLLOW-UP STUDY
J. Thorac. Cardiovasc. Surg., July 1, 1996; 112(1): 69 - 78.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1981 by The American Association for Thoracic Surgery.