JTCS Sign the Guestbook
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gonzalez, A. C.
Right arrow Articles by Fisk, R. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gonzalez, A. C.
Right arrow Articles by Fisk, R. L.

The Journal of Thoracic and Cardiovascular Surgery, Vol 89, 386-399, Copyright © 1985 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Acute right ventricular failure is caused by inadequate right ventricular hypothermia

AC Gonzalez, TA Brandon, RL Fortune, SF Casano, M Martin, DL Benneson, EJ Guilbeau and RL Fisk

The hypothesis of this study was that inadequate right ventricular hypothermia contributes to the right ventricular dysfunction occasionally observed after cardiac operations. Dogs were placed on cardiopulmonary bypass, and 60 minute periods of hypothermic myocardial ischemia were imposed. Left ventricular temperature was always maintained at 15 degrees C and right ventricular temperatures were maintained at 15 degrees C (Group I, n = 8), 25 degrees C (Group II, n = 8), and 35 degrees C (Group III, n = 8). These temperatures were produced by infusion of hypothermic crystalloid cardioplegic solution and appropriate topical cooling and heating of the left and right ventricles, respectively. Multiple indices of ventricular function were obtained 15, 30, 45, and 60 minutes after bypass and compared to prebypass control values. In all Group I animals (left ventricular temperature = 15 degrees C, right ventricular temperature = 15 degrees C), postischemic indices of right ventricular function were not different from control values (p = NS). In Group II (left ventricular temperature = 15 degrees C, right ventricular temperature = 25 degrees C), two animals died 30 and 45 minutes after bypass, respectively, of right ventricular failure. In the other six animals in Group II, all indices of right ventricular function were significantly reduced (p less than 0.05) except for right ventricular systolic pressure. In Group III (left ventricular temperature = 15 degrees C, right ventricular temperature = 35 degrees C), two animals could not be weaned from cardiopulmonary bypass because of right ventricular akinesia. Six animals were weaned from bypass, but two died 15 minutes, one died 30 minutes, and one 45 minutes after bypass. Two animals lived 60 minutes, but all indices of right ventricular function were decreased. Failure to maintain right ventricular temperatures below 25 degrees C during 1 hour of cardiac ischemia in the dog can result in fatal right ventricular failure.


This article has been cited by other articles:


Home page
ICVTSHome page
S. Osaki, N. M. Edwards, M. R. Johnson, and T. Kohmoto
A novel use of the implantable ventricular assist device for isolated right heart failure
Interactive CardioVascular and Thoracic Surgery, August 1, 2008; 7(4): 651 - 653.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
R Dhillon, M Josen, M Henein, and A Redington
Transcatheter closure of atrial septal defect preserves right ventricular function
Heart, May 1, 2002; 87(5): 461 - 465.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
N. Ad, E. Birk, J. Barak, S. Diamant, E. Snir, and B. A. Vidne
A ONE-WAY VALVED ATRIAL SEPTAL PATCH: A NEW SURGICAL TECHNIQUE AND ITS CLINICAL APPLICATION
J. Thorac. Cardiovasc. Surg., April 1, 1996; 111(4): 841 - 848.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
C. O. Murphy, Pan-Chih, J. P. Gott, and R. A. Guyton
Microvascular Reactivity After Crystalloid, Cold Blood, and Warm Blood Cardioplegic Arrest
Ann. Thorac. Surg., October 1, 1995; 60(4): 1021 - 1027.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
V. G. Davila-Roman, A. D. Waggoner, W. E. Hopkins, and B. Barzilai
Right Ventricular Dysfunction in Low Output Syndrome After Cardiac Operations: Assessment by Transesophageal Echocardiography
Ann. Thorac. Surg., October 1, 1995; 60(4): 1081 - 1086.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
N. Ad, J. Barak, E. Birk, S. Diamant, and B. A. Vidne
A one-way, valved, atrial septal patch in the management of postoperative right heart failure:An animal study
J. Thorac. Cardiovasc. Surg., July 1, 1994; 108(1): 134 - 139.
[Abstract] [Full Text]


Home page
PerfusionHome page
J. B Riley, S. B Hardin, B. A Winn, and M. B Hurdle
In vitro comparison of cavoatrial (dual stage) cannulae for use during cardiopulmonary bypass
Perfusion, July 1, 1986; 1(3): 197 - 204.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1985 by The American Association for Thoracic Surgery.