JTCS Sign the Guestbook
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Christie, G. W.
Right arrow Articles by Barratt-Boyes, B. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Christie, G. W.
Right arrow Articles by Barratt-Boyes, B. G.

The Journal of Thoracic and Cardiovascular Surgery, Vol 90, 901-906, Copyright © 1985 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Graft detachment, a cause of incompetence in stent-mounted aortic valve allografts

GW Christie, JB Gavin and BG Barratt-Boyes

The detachment of allograft tissue from supporting stent posts has been a common mode of failure of stent-mounted aortic allografts. In an effort to reduce the localized stress loading on the tissue at the top of the stent posts, two changes were introduced to the previous fabrication protocol followed by Green Lane Hospital. Specifically, they were the use of a flexible acetyl-copolymer stent and covering of the peripheral attachment sutures with a bias strip of Dacron cloth. This study showed that these changes did not reduce the incidence of allograft failure caused by graft detachment. Unexpectedly, covering antibiotic-treated allograft tissue with a bias strip actually increased the likelihood of failure of the valve, by accelerating the biological degradation of the underlying graft aortic wall. The weakened aortic wall tissue was consequently less able to resist the high stress loadings at the top of the stent posts where detachment first occurred.


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
B. G. Barratt-Boyes, W. M. Jaffe, and R. M. Whitlock
THE MEDTRONIC INTACT* PORCINE VALVE: TEN-YEAR CLINICAL REVIEW
J. Thorac. Cardiovasc. Surg., December 1, 1998; 116(6): 1005 - 1014.