JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sethia, B.
Right arrow Articles by Bain, W. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sethia, B.
Right arrow Articles by Bain, W. H.

The Journal of Thoracic and Cardiovascular Surgery, Vol 91, 350-361, Copyright © 1986 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Fourteen years' experience with the Bjork-Shiley tilting disc prosthesis

B Sethia, MA Turner, S Lewis, RA Rodger and WH Bain

Between 1970 and 1984, 1,574 Bjork-Shiley valve prostheses have been implanted in 1,171 patients in Glasgow. Between 1970 and 1980, 1,023 standard disc prostheses were implanted in 729 patients: 184 had aortic valve replacement, 323 mitral, and 222 multiple valve replacement. Between 1980 and 1984, 551 convexo-concave valves were implanted in 442 patients: 125 had aortic, 228 mitral, and 89 multiple valve replacement. Concomitant coronary artery bypass grafting was performed in 9.2% of the latter group as compared with 2.7% of the earlier group. The overall hospital (30 day) mortality for the group with the standard disc prosthesis was 10.4% and for patients with the convexo-concave prosthesis, 7.0%. Cumulative follow-up extends to 4,125 patient-years-- standard disc group 3,378 patients-years, range 4 to 14 years (mean 5.2 years); convexo-concave group 747 patient-years, range 1.5 to 5.3 years (mean 1.9 years). The late mortality is 3.8% per patient-year--standard disc group 2.9% per patient-year and convexo-concave group 4.3% per patient year (no significant difference). Actuarial survival rate at 12 years for the whole group, excluding operative deaths, is 69.4% +/- 6.3%. The freedom from all valve-related complications at 12 years is 65.9% +/- 6.5%. there is no significant difference in the incidence of most major complications between the standard disc and convexo-concave prostheses apart from the occurrence of mitral valve thrombosis (p less than 0.05) in the standard disc group and outlet strut fracture (p less than 0.005) in the convexo-concave group. These results confirm the excellent long-term performance of the Bjork-Shiley tilting disc prosthesis.


This article has been cited by other articles:


Home page
ChestHome page
D. N. Salem, P. T. O'Gara, C. Madias, and S. G. Pauker
Valvular and Structural Heart Disease: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines (8th Edition)
Chest, June 1, 2008; 133(6_suppl): 593S - 629S.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
Q.-Q. Han, Z.-Y. Xu, B.-R. Zhang, L.-J. Zou, J.-H. Hao, and S.-D. Huang
Primary triple valve surgery for advanced rheumatic heart disease in Mainland China: a single-center experience with 871 clinical cases
Eur. J. Cardiothorac. Surg., May 1, 2007; 31(5): 845 - 850.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. N. Salem, P. D. Stein, A. Al-Ahmad, H. I. Bussey, D. Horstkotte, N. Miller, and S. G. Pauker
Antithrombotic Therapy in Valvular Heart Disease--Native and Prosthetic: The Seventh ACCP Conference on Antithrombotic and Thrombolytic Therapy
Chest, September 1, 2004; 126(3_suppl): 457S - 482S.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. Vink, R. A. Kraaijenhagen, B. A. Hutten, R. B. A. van den Brink, B. A. de Mol, H. R. Buller, and M. Levi
The optimal intensity of vitamin k antagonists in patients with mechanical heart valves: A meta-analysis
J. Am. Coll. Cardiol., December 17, 2003; 42(12): 2042 - 2048.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
P. D. Stein, J. S. Alpert, H. I. Bussey, J. E. Dalen, and A. G.G. Turpie
Antithrombotic Therapy in Patients With Mechanical and Biological Prosthetic Heart Valves
Chest, January 1, 2001; 119 (2009): 220S - 227S.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. John, E. Ravikumar, C. N. John, and V. V. Bashi
25-year experience with 456 combined mitral and aortic valve replacement for rheumatic heart disease
Ann. Thorac. Surg., April 1, 2000; 69(4): 1167 - 1172.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
K. D. Hopper, I. C. Gilchrist, J. R. Landis, A. H. Abolfathi, A. Russell Localio, R. P. Wilson, W. E. Pae Jr., A. R. Kunselman, D. W. Wieting, J. W. Griffith, et al.
In Vivo Accuracy Of Two Radiographic Systems In The Detection Of Bjork-Shiley Convexo-Concave Heart Valve Outlet Strut Single Leg Separations
J. Thorac. Cardiovasc. Surg., March 1, 1998; 115(3): 582 - 586.
[Abstract] [Full Text]


Home page
NEJMHome page
W. W. O'Neill, J. G. Chandler, R. E. Gordon, D. M. Bakalyar, A. H. Abolfathi, M. D. Castellani, J. L. Hirsch, D. W. Wieting, J. S. Bassett, K. C. Beatty, et al.
Radiographic Detection of Strut Separations in Bjork-Shiley Convexo-Concave Mitral Valves
N. Engl. J. Med., August 17, 1995; 333(7): 414 - 420.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
M. H. Eckman, H. J. Levine, and S. G. Pauker
Effect of Laboratory Variation in the Prothrombin-Time Ratio on the Results of Oral Anticoagulant Therapy
N. Engl. J. Med., September 2, 1993; 329(10): 696 - 702.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1986 by The American Association for Thoracic Surgery.