JTCS KCI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Walley, V. M.
Right arrow Articles by Keon, W. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Walley, V. M.
Right arrow Articles by Keon, W. J.

The Journal of Thoracic and Cardiovascular Surgery, Vol 93, 925-933, Copyright © 1987 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Patterns of failure in Ionescu-Shiley bovine pericardial bioprosthetic valves

VM Walley and WJ Keon

The experience of the University of Ottawa Heart Institute with valvular replacement by Ionescu-Shiley bovine pericardial bioprostheses has been recently reviewed. The focus of the present study is to examine the patterns of valve failure in a subgroup of these prostheses, those that required explanation for valve failure caused specifically by cusp wear and tears. A total of 22 aortic and six mitral standard-profile valves failed in this way. Twenty-five of these valves were reassessed and are the subject of this paper. Twenty-eight holes and 56 cusp tears occurred in these valves in locations which, along with coexistent pathologic findings, suggested that the cusp commissural suture/alignment stitch was the point of their origin. The importance of this observation and postulation about the genesis of these cases of valve failure lies in the potential for improvement of this valve's performance by modifications of its manufacture.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
R. S. McClure, N. Narayanasamy, E. Wiegerinck, S. Lipsitz, A. Maloney, J. G. Byrne, S. F. Aranki, G. S. Couper, and L. H. Cohn
Late Outcomes for Aortic Valve Replacement With the Carpentier-Edwards Pericardial Bioprosthesis: Up to 17-Year Follow-Up in 1,000 Patients
Ann. Thorac. Surg., May 1, 2010; 89(5): 1410 - 1416.
[Abstract] [Full Text] [PDF]


Home page
Interact CardioVasc Thorac SurgHome page
K. Honda, Y. Okamura, Y. Nishimura, and S. Uchita
Twenty-six-year durability of an Ionescu-Shiley standard profile pericardial aortic valve
Interact CardioVasc Thorac Surg, February 1, 2010; 10(2): 315 - 316.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. Mohammadi, R. Baillot, P. Voisine, P. Mathieu, and F. Dagenais
Structural deterioration of the Freestyle aortic valve: Mode of presentation and mechanisms.
J. Thorac. Cardiovasc. Surg., August 1, 2006; 132(2): 401 - 406.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. P.A. Puvimanasinghe, J. J.M. Takkenberg, M. J.C. Eijkemans, E. W. Steyerberg, L. A. van Herwerden, G. L. Grunkemeier, J. D. F. Habbema, and A. J.J.C. Bogers
Prognosis After Aortic Valve Replacement With the Carpentier-Edwards Pericardial Valve: Use of Microsimulation
Ann. Thorac. Surg., September 1, 2005; 80(3): 825 - 831.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
F. J. Schoen and R. J. Levy
Calcification of Tissue Heart Valve Substitutes: Progress Toward Understanding and Prevention
Ann. Thorac. Surg., March 1, 2005; 79(3): 1072 - 1080.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Le Tourneau, A. Vincentelli, G. Fayad, C. Savoye, O. H. Fabre, A. Prat, and H. Warembourg
Ten-year echocardiographic and clinical follow-up of aortic Carpentier-Edwards pericardial and supraannular prosthesis: a case-match study
Ann. Thorac. Surg., December 1, 2002; 74(6): 2010 - 2015.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. Dellgren, T. E. David, E. Raanani, S. Armstrong, J. Ivanov, and H. Rakowski
Late hemodynamic and clinical outcomes of aortic valve replacement with the Carpentier-Edwards Perimount pericardial bioprosthesis
J. Thorac. Cardiovasc. Surg., July 1, 2002; 124(1): 146 - 154.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
T. Le Tourneau, C. Savoye, E. P. McFadden, D. Grandmougin, H.-F. Carton, J.-L. Hennequin, A. Dubar, G. Fayad, and H. Warembourg
Mid-Term Comparative Follow-Up After Aortic Valve Replacement with Carpentier-Edwards and Pericarbon Pericardial Prostheses
Circulation, November 9, 1999; 100(90002): II-11 - II-16.
[Abstract] [Full Text] [PDF]


Home page
J Biomater ApplHome page
J. M. G. Paez and E. Jorge-Herrero
Assessment of Pericardium in Cardiac Bioprostheses: A Review
J Biomater Appl, April 1, 1999; 13(4): 351 - 388.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. R. Aupart, P. H. Neville, S. Hammami, A. L. Sirinelli, Y. A. Meurisse, and M. A. Marchand
CARPENTIER-EDWARDS PERICARDIAL VALVES IN THE MITRAL POSITION: TEN-YEAR FOLLOW-UP
J. Thorac. Cardiovasc. Surg., March 1, 1997; 113(3): 492 - 498.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
M. R. Aupart, A. L. Sirinelli, F. F. Diemont, Y. A. Meurisse, X. B. Dreyfus, and M. A. Marchand
The Last Generation of Pericardial Valves in the Aortic Position: Ten-Year Follow-up in 589 Patients
Ann. Thorac. Surg., February 1, 1996; 61(2): 615 - 620.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. M. Cosgrove, B. W. Lytle, P. C. Taylor, M. T. Camacho, R. W. Stewart, P. M. McCarthy, D. P. Miller, M. R. Piedmonte, and F. D. Loop
The Carpentier-Edwards pericardial aortic valve: Ten-year results
J. Thorac. Cardiovasc. Surg., September 1, 1995; 110(3): 651 - 662.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
M. Pellerin, S. Mihaileanu, J. Paul Couetil, J. Y. M. Relland, A. Deloche, J.-N. Fabiani, A. Jindani, and A. F. Carpentier
Carpentier-edwards pericardial bioprosthesis in aortic position: Long-term follow-up 1980 to 1994
Ann. Thorac. Surg., August 1, 1995; 60(suppl_2): S292 - S296.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. A. Moggio, R. W. Pooley, M. R. Sarabu, J. Christiana, A. W. Ho, and G. E. Reed
Experience with the Mitroflow aortic bioprosthesis
J. Thorac. Cardiovasc. Surg., August 1, 1994; 108(2): 215 - 220.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
U. Bortolotti, P. Ius, G. Thiene, M. Minarini, A. Milano, C. Valfre, E. Talenti, M. Valente, and A. Mazzucco
The meadox-gabbay pericardial xenograft: Failure of the unicusp principle
Ann. Thorac. Surg., November 1, 1992; 54(5): 952 - 957.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
V. M. Walley, C. A. Keon, M. Khalili, D. Moher, M. Campagna, and W. J. Keon
Ionescu-Shiley valve failure I: Experience with 125 standard-profile explants
Ann. Thorac. Surg., July 1, 1992; 54(1): 111 - 116.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
V. M. Walley, C. A. Keon, M. Khalili, D. Moher, M. Campagna, and W. J. Keon
Ionescu-Shiley valve failure II: Experience with 25 low-profile expiants
Ann. Thorac. Surg., July 1, 1992; 54(1): 117 - 122.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
U. Bortolotti, A. Milano, F. Guerra, A. Mazzucco, E. Mossuto, G. Thiene, and V. Gallucci
Failure of Hancock pericardial xenografts: Is prophylactic bioprosthetic replacement justified?
Ann. Thorac. Surg., March 1, 1991; 51(3): 430 - 437.
[Abstract] [PDF]


Home page
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in MedicineHome page
J. Fisher, T. J. Spyt, and D. J. Wheatley
Failure and Hydrodynamic Function Testing of Explanted Pericardial and Porcine Bioprosthetic Valves
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, June 1, 1989; 203(2): 65 - 70.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
L. C. Pelletier, M. Carrier, Y. Leclerc, G. Lepage, P. deGuise, and I. Dyrda
Porcine versus pericardial bioprostheses: A comparison of late results in 1,593 patients
Ann. Thorac. Surg., March 1, 1989; 47(3): 352 - 361.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1987 by The American Association for Thoracic Surgery.