JTCS St. Jude Medical
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bonchek, L. I.
Right arrow Articles by Vazales, B. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bonchek, L. I.
Right arrow Articles by Vazales, B. E.

The Journal of Thoracic and Cardiovascular Surgery, Vol 94, 632-634, Copyright © 1987 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Accuracy of sizers for aortic valve prostheses

LI Bonchek, MW Burlingame and BE Vazales
Division of Cardiothoracic Surgery, Lancaster General Hospital, Pa.

Accurate sizing of the aortic anulus is a prerequisite of prosthetic valve implantation, because it is usually desirable to insert the largest possible prosthesis. Although it is generally assumed that commercial valve sizers are accurately labeled, our measurements reveal that the sizers for the St. Jude Medical, Bjork-Shiley, and Ionescu- Shiley prostheses are larger than their nominal sizes. These findings are relevant to the selection of prosthetic valves.


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
B. A. Youdelman, H. Hirose, H. Jain, J. Y. Kresh, J. W.C. Entwistle III, and A. S. Wechsler
Comparison of eight prosthetic aortic valves in a cadaver model.
J. Thorac. Cardiovasc. Surg., December 1, 2007; 134(6): 1526 - 1532.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
D. P. Taggart
Prosthesis patient mismatch in aortic valve replacement: possible but pertinent?
Eur. Heart J., March 2, 2006; 27(6): 644 - 646.
[Full Text] [PDF]


Home page
MMCTSHome page
M. Turina
Supra-annular aortic valve replacement with a mechanical prosthesis
MMCTS, November 29, 2005; 2005(1129): 646.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
H.-H. Sievers
Prosthetic aortic valve replacement
J. Thorac. Cardiovasc. Surg., May 1, 2005; 129(5): 961 - 965.
[Full Text] [PDF]


Home page
CirculationHome page
T. Walther, S. Lehmann, V. Falk, S. Metz, N. Doll, A. Rastan, M. Viehweg, M. Richter, J. Gummert, and F. W. Mohr
Prospectively Randomized Evaluation of Stented Xenograft Hemodynamic Function in the Aortic Position
Circulation, September 14, 2004; 110(11_suppl_1): II-74 - II-78.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
R. Seitelberger, J. Bialy, R. Gottardi, G. Seebacher, R. Moidl, M. Mittelbock, P. Simon, and E. Wolner
Relation between size of prosthesis and valve gradient: comparison of two aortic bioprosthesis
Eur. J. Cardiothorac. Surg., March 1, 2004; 25(3): 358 - 363.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. B. Chambers, L. Oo, A. Narracott, P. M. Lawford, and C. I. Blauth
Nominal size in six bileaflet mechanical aortic valves: A comparison of orifice size and biologic equivalence
J. Thorac. Cardiovasc. Surg., June 1, 2003; 125(6): 1388 - 1393.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. Pibarot and J. G. Dumesnil
Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention
J. Am. Coll. Cardiol., October 1, 2000; 36(4): 1131 - 1141.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
V. Rao, G. T. Christakis, J. Sever, S. E. Fremes, G. Bhatnagar, G. Cohen, M. A. Borger, L. Abouzahr, and B. S. Goldman
A NOVEL COMPARISON OF STENTLESS VERSUS STENTED VALVES IN THE SMALL AORTIC ROOT
J. Thorac. Cardiovasc. Surg., March 1, 1999; 117(3): 431 - 438.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. T. Christakis, K. J. Buth, B. S. Goldman, S. E. Fremes, V. Rao, G. Cohen, M. A. Borger, and R. D. Weisel
Inaccurate and misleading valve sizing: a proposed standard for valve size nomenclature
Ann. Thorac. Surg., October 1, 1998; 66(4): 1198 - 1203.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Bartels and H.-H. Sievers
Reply
Ann. Thorac. Surg., September 1, 1998; 66(3): 985 - 985.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
L. I. Bonchek
Why aren't valve sizers and prostheses labeled accurately?
Ann. Thorac. Surg., September 1, 1998; 66(3): 984 - 985.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Bartels, R. G. Leyh, J.F. M. Bechtel, E. Joubert-Hubner, and H.-H. Sievers
Discrepancies Between Sizer and Valve Dimensions: Implications for Small Aortic Root
Ann. Thorac. Surg., June 1, 1998; 65(6): 1631 - 1633.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1987 by The American Association for Thoracic Surgery.