JTCS Click here to go to SJM website.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brunsting, L. A.
Right arrow Articles by Wechsler, A. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brunsting, L. A.
Right arrow Articles by Wechsler, A. S.

The Journal of Thoracic and Cardiovascular Surgery, Vol 94, 904-910, Copyright © 1987 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Myocardial protective effects of the class Ic antiarrhythmic agent flecainide

LA Brunsting, ME Jessen, AS Abd-Elfattah, WK Mask, CK Godwin and AS Wechsler
Department of Surgery, Duke University Medical Center, Durham, NC 27710.

The class Ic antiarrhythmic agent flecainide has recently become available in this country for management of ventricular arrhythmias. The pharmacologic and electrophysiologic features of this class of drug- -marked sodium channel blockade producing inhibition of phase 0 of the myocardial action potential, moderate blockade of slow inward (calcium) channels, and general lack of systemic toxicity--suggest that these agents may exert significant myocardial protective effects. This hypothesis was tested in isolated, perfused rat hearts subjected to 30 minutes of global normothermic ischemia followed by 30 minutes of reperfusion after pretreatment with (1) Krebs-Henseleit buffer (n = 7); (2) Krebs-Henseleit buffer with potassium adjusted to 20.9 mmol/L with potassium chloride (n = 10); and (3) Krebs-Henseleit buffer plus flecainide acetate 50 mg/L (0.12 mmol/L) (n = 11). Severity of ischemic injury was assessed by time to ischemic contracture: 9.9 +/- 1.3 (Krebs- Henseleit buffer), 18.4 +/- 1.1 (potassium chloride), and 25.4 +/- 1.0 (flecainide) minutes (mean +/- standard error of the mean) (p less than 0.05 among all groups). Functional recovery after ischemia and reperfusion was measured by developed pressure (expressed as percent of preischemic control): 19.6 +/- 5.4 (Krebs-Henseleit buffer), 70.8 +/- 3.2 (potassium chloride), and 67.3 +/- 2.7 (flecainide). These results suggest that class Ic agents afford significant myocardial protection from global normothermic ischemia.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1987 by The American Association for Thoracic Surgery.