JTCS Tips for Better Browsing
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Milano, A. D.
Right arrow Articles by Gallucci, V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Milano, A. D.
Right arrow Articles by Gallucci, V.

The Journal of Thoracic and Cardiovascular Surgery, Vol 98, 37-47, Copyright © 1989 by The American Association for Thoracic Surgery and The Western Thoracic Surgical Association


ARTICLES

Aortic valve replacement with the Hancock standard, Bjork-Shiley, and Lillehei-Kaster prostheses. A comparison based on follow-up from 1 to 15 years

AD Milano, U Bortolotti, A Mazzucco, F Guerra, A Magni and V Gallucci
Department of Cardiovascular Surgery, University of Padova Medical School, Italy.

Three series of patients undergoing isolated aortic valve replacement with the standard glutaraldehyde-preserved Hancock porcine bioprosthesis, the standard Bjork-Shiley spherical disc prosthesis, and the Lillehei-Kaster tilting disc prosthesis were compared during a 15- year follow-up. From March 1970 to December 1985, aortic valve replacement was performed in 506 patients, 379 men and 109 women, whose ages ranged from 17 to 71 years (mean, 47 +/- 12 years); 196 had a Hancock bioprosthesis, 147 a Bjork-Shiley prosthesis, and 163 a Lillehei-Kaster prosthesis. There were no significant differences among the three groups in terms of mean age, preoperative New York Heart Association class, valve lesion, associated intracardiac procedures, and operative mortality (11.7% for the Hancock bioprosthesis group, 8.8% for the Bjork-Shiley prosthesis group, and 9.2% for the Lillehei- Kaster prosthesis group). Cumulative duration of follow-up is 1140 patient-years (mean, 6.6 +/- 1.5 years, 100% complete) for Hancock bioprosthesis patients, 878 patient-years (mean, 5.9 +/- 0.4 years, 98% complete) for Bjork-Shiley prosthesis patients, and 1184 patient-years (mean, 7.3 +/- 0.3 years, 97% complete) for Lillehei-Kaster prosthesis patients. Actuarial survival rates at 15 years are 30% +/- 15% for Hancock bioprosthesis, 49% +/- 6% for Bjork-Shiley prosthesis, and 44% +/- 7% for Lillehei-Kaster prosthesis patients. There were eight embolic episodes in Hancock valve recipients (0.7% +/- 0.1%/pt-yr), nine in Bjork-Shiley prosthesis recipients (1.0% +/- 0.3%/pt-yr), and nine (0.7% +/- 0.1%/pt-yr) in Lillehei-Kaster prosthesis recipients (p = no significant difference). Actuarial freedom from emboli at 15 years is 89% +/- 4% for Hancock, 92% +/- 3% for Bjork-Shiley, and 93% +/- 2% for Lillehei-Kaster prosthesis recipients (p = no significant difference). A significant difference was found in the incidence of the following complications. (1) Anticoagulant-related hemorrhage: 0.1% +/- 0.1%/pt-yr for Hancock bioprosthesis, 1.3% +/- 0.3%/pt-yr for Bjork- Shiley prosthesis, and 1.9% +/- 0.4%/pt-yr for Lillehei-Kaster prosthesis patients (p less than 0.001), with an actuarial freedom at 15 years of 97.6% +/- 1% for Hancock, 85% +/- 5% for Bjork-Shiley, and 68.8% +/- 10% for Lillehei-Kaster recipients (p less than 0.001). (2) Structural deterioration: 3.7% +/- 0.6%/pt-yr for Hancock and none for Bjork-Shiley and Lillehei-Kaster patients (p less than 0.001), with an actuarial freedom of 100% for Bjork-Shiley prosthesis and Lillehei- Kaster prosthesis patients and 38.4% +/- 12% for Hancock bioprosthesis patients at 15 years.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
S. John, E. Ravikumar, C. N. John, and V. V. Bashi
25-year experience with 456 combined mitral and aortic valve replacement for rheumatic heart disease
Ann. Thorac. Surg., April 1, 2000; 69(4): 1167 - 1172.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. S. Peterseim, Y.-Y. Cen, S. Cheruvu, K. Landolfo, T. M. Bashore, J. E. Lowe, W. G. Wolfe, and D. D. Glower
LONG-TERM OUTCOME AFTER BIOLOGIC VERSUS MECHANICAL AORTIC VALVE REPLACEMENT IN 841 PATIENTS
J. Thorac. Cardiovasc. Surg., May 1, 1999; 117(5): 890 - 897.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. A. Orszulak, H. V. Schaff, C. J. Mullany, B. J. Anderson, D. M. Ilstrup, F. J. Puga, and G. K. Danielson
Risk of Thromboembolism With the Aortic Carpentier-Edwards Bioprosthesis
Ann. Thorac. Surg., February 1, 1995; 59(2): 462 - 468.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1989 by The American Association for Thoracic Surgery.