JTCS KCI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Okada, S.
Right arrow Articles by Tanaba, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Okada, S.
Right arrow Articles by Tanaba, Y.
Related Collections
Right arrow Trachea and bronchi

J Thorac Cardiovasc Surg 2002;124:1032-1034
© 2002 The American Association for Thoracic Surgery


Brief Communications

Placement of self-expandable metallic stents with a laryngeal mask and a fiberoptic flexible bronchoscope for obstructive tracheobronchial lesions

Shinichiro Okada, MD, Shotaro Ishimori, MD, Shunsuke Yamagata, MD, Shoichi Satoh, MD, Sadanori Yaegashi, MD, Yoshiaki Tanaba, MD Iwate, Japan

From the Department of Thoracic Surgery and Medicine, Kamaishi Municipal Hospital, Iwate, Japan.

Received for publication April 15, 2002. Accepted for publication June 5, 2002. Address for reprints: Shinichiro Okada, MD, Department of Thoracic Surgery and Medicine, Kamaishi Municipal Hospital, 3-15-26, Ohwatari-cho, Kamaishi, Iwate, 026-0025 Japan (E-mail: shin575@opal.famille.ne.jp).

The first 20% of the full text of this article appears below.

Self-expandable metallic stents have been used in the management of malignant or benign tumors causing airway stenosis or obstruction by means of a rigid bronchoscope or fluoroscopic control.Go 1 However, fully trained personnel are needed to manage the rigid bronchoscope, and the sites to be reached with it are limited. Additionally, mandibular arthrosis, or limited mouth opening, or spinal deformities might present technical problems with the rigid bronchoscope. On the other hand, it might often be difficult to achieve the exact fitting of the stent under fluoroscopic control.

The laryngeal mask is a reusable device with a larger internal diameter, allowing easier passage of a fiberoptic flexible bronchoscope or instruments (Figure 1, A), and does not require the usual endotracheal intubation or mask ventilation.Go Go 2-5 In this report we describe a procedure of inserting a self-expandable metallic stent under direct visual control with the use of the new laryngeal mask and a fiberoptic flexible bronchoscope in the management of tracheobronchial obstructive lesions.


Figure Removed (Available Only in the Full Text)
View larger version (33K):
[in this window]
[in a new window]
 
Fig. 1. A, A laryngeal mask airway. B, Placement of the laryngeal mask. The deflated cuff of the laryngeal mask is introduced . . . [Full Text of this Article]

 






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 by The American Association for Thoracic Surgery.